Structured Alarm Management Program and Alarm Fatigue in ICU Nurses
The Effect of a Structured Alarm Management Program Developed for Intensive Care Nurses on Alarm Fatigue and Alarm Frequency
H1: Nurses' Alarm Fatigue Scale scores differ following the implementation of the Structured Alarm Management Program in the intensive care unit compared with their pre-intervention scores.
H2: The total number of alarms in the intensive care unit differs following the implementation of the Structured Alarm Management Program compared with the pre-intervention period.
H3: The mean daily number of alarms per patient in the intensive care unit differs following the implementation of the Structured Alarm Management Program compared with the pre-intervention period.
Aim of the Study This study is designed as a single-group, pretest-posttest, quasi-experimental pilot study to evaluate the effect of a structured alarm management program developed for intensive care nurses on alarm fatigue and alarm frequency
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
Intensive care units (ICUs) are highly technologically advanced healthcare settings in which individuals with life-threatening acute or chronic conditions receive specialized treatment and care under continuous monitoring. In these units, patients' vital functions are continuously monitored using multiparameter monitors, mechanical ventilators, infusion pumps, renal replacement therapy systems, and other advanced life-support devices. These devices are equipped with alarm systems designed to alert healthcare professionals to changes in patients' physiological conditions. Alarm systems play a critical role in ensuring patient safety by facilitating the early detection of clinical deterioration . However, the increasing use of medical technology has led to a substantial rise in the number of alarms generated in intensive care settings. The literature indicates that a considerable proportion of alarms generated in ICUs are false-positive, technically induced, or clinically non-actionable, with approximately 72-99% of physiological monitor alarms requiring no clinical intervention. Frequent and repetitive exposure to clinically insignificant alarms may gradually desensitize healthcare professionals to alarm signals, contributing to a major patient safety concern known as "alarm fatigue".
Alarm fatigue is defined as the desensitization of healthcare professionals to alarm signals resulting from frequent and unnecessary alarm exposure. Furthermore, alarm fatigue may lead to delayed alarm responses, failure to recognize critical alarms, and compromised patient safety. Recent studies have reported that alarm fatigue is prevalent among intensive care nurses.
Several factors contribute to the development of alarm fatigue, including excessive alarm frequency, high rates of false-positive alarms, failure to individualize alarm limits according to patients' clinical conditions, heavy workloads, inadequate staffing, prolonged working hours, insufficient training, and the absence of standardized alarm management protocols. Consequently, recent efforts to reduce alarm fatigue have focused on structured alarm management education, individualized adjustment of alarm thresholds, technological solutions such as centralized alarm management systems, and the development of institution-based alarm management strategies.
In this context, structured alarm management education is considered an effective intervention aimed at improving nurses' knowledge, skills, and awareness of alarm management; supporting the individualization of alarm limits within clinically appropriate and safe ranges according to patients' conditions; reducing unnecessary alarm burden; and enhancing patient safety. Structured educational programs have been reported to improve nurses' knowledge of alarm management, promote appropriate alarm management practices, and contribute to reducing alarm fatigue.
Although previous studies have investigated the effects of educational interventions on alarm fatigue among intensive care nurses, studies simultaneously evaluating the effects of structured alarm management programs on both alarm fatigue and alarm burden remain limited. This gap highlights the need for further research to scientifically evaluate the effectiveness of structured alarm management programs. Accordingly, the present study aims to evaluate the effect of a structured alarm management program implemented among intensive care nurses on alarm fatigue and alarm frequency. The findings of this study are expected to contribute to the development of evidence-based alarm management practices, the enhancement of patient safety, and the planning of educational programs for intensive care nurses.
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: AYNUR Cengiz
- Telefoonnummer: +905309200580
- E-mail: aynurcngz@mersin.edu.tr
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
The following nurses will be eligible for inclusion in the study:
- Nurses with at least three months of intensive care experience.
- Nurses actively working in the intensive care unit.
- Nurses who voluntarily agree to participate in the study.
- Nurses who provide written informed consent by signing the Informed Consent Form.
- Nurses who are able to participate in the educational program. In addition, devices that generate alarms and allow alarm data to be recorded will be included in the study
Exclusion Criteria:
The following nurses will be excluded from the study:
- Nurses with less than three months of experience in the intensive care unit.
- Nurses who do not wish to participate in the study. In addition, devices that generate alarms but do not allow alarm data to be recorded, such as infusion pumps and continuous renal replacement therapy (CRRT) devices, will be excluded from the study.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ondersteunende zorg
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: EDUCATION GROUP
ALARM MANAGEMENT EDUCATION |
The educational content of the Structured Alarm Management Program will be developed in four modules. Module 1 will cover an introduction to clinical alarms and basic physiological parameters; Module 2 will address factors contributing to alarm generation and their effects on healthcare professionals; Module 3 will focus on physiological monitor alarm management strategies; and Module 4 will cover mechanical ventilator alarm management strategies. The topics included in each module will be developed based on the relevant literature. The training sessions will be scheduled according to nurses' working hours to ensure that all participating nurses receive the education. If necessary, the sessions will be repeated at different times until all nurses have completed the training program. The educational content will initially be prepared in written form and submitted for expert review to assess its scope and content validity. Following the necessary revisions based on expert |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Change in Nurses' Alarm Fatigue Scale Scores Following the Structured Alarm Management Program
Tijdsspanne: 9 MONTH
|
Alarm fatigue among intensive care nurses will be assessed using the 12-item Alarm Fatigue Scale developed by Torabizadeh et al. (2017) and validated in Turkish by Alan et al. (2021). Each item is rated on a five-point Likert scale ranging from 0 (never) to 4 (always), yielding a total score between 0 and 48. Higher scores indicate greater levels of alarm fatigue. The scale will be administered before the implementation of the Structured Alarm Management Program and again after completion of the one-month intervention period. The primary outcome will be the change in total Alarm Fatigue Scale scores between the pre-intervention and post-intervention assessments. This comparison will be used to evaluate whether the structured educational intervention combined with the Alarm Management Care Bundle is associated with a reduction in alarm fatigue among intensive care nurses. |
9 MONTH
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Change in Total Clinical Alarm Frequency Following the Structured Alarm Management Program Change in Mean Daily Number of Clinical Alarms per Patient Following the Structured Alarm Management Program
Tijdsspanne: 9 MONTH
|
Alarm fatigue among intensive care nurses will be assessed using the 12-item Alarm Fatigue Scale developed by Torabizadeh et al. (2017) and validated in Turkish by Alan et al. (2021). Each item is rated on a five-point Likert scale ranging from 0 (never) to 4 (always), yielding a total score between 0 and 48. Higher scores indicate greater levels of alarm fatigue. The scale will be administered before the implementation of the Structured Alarm Management Program and again after completion of the one-month intervention period. The primary outcome will be the change in total Alarm Fatigue Scale scores between the pre-intervention and post-intervention assessments. This comparison will be used to evaluate whether the structured educational intervention combined with the Alarm Management Care Bundle is associated with a reduction in alarm fatigue among intensive care nurses. |
9 MONTH
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2026/571
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
IPD delen Ondersteunend informatietype
- LEERPROTOCOOL
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .