- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT03577340
Development and Validation of Performance Metrics for Cardiac Device Implant Procedures
Development and Validation of Performance Metrics for Cardiac Device
Cardiac Device implantation includes implantation of pacemakers, implantable defibrillators and Cardiac resynchronisation Therapy (CRT) devices. These are well-established treatments for selected with heart rhythm abnormalities and heart failure.
In the past, trainee doctors had the opportunity to perform many procedures and learn on the patient. This is no longer the case due to a change in training schedules and working times as well as patient safety mandates. Progression based training with the use of simulators has been proven to be effective in training and in order to use this methodology, the procedure needs to be well defined.
Despite its worldwide adoption, a standardized procedure has never been defined in detail and agreed upon and the cardiac device implant technique varies with the operator.
The purpose of the research is to establish the metrics (operational definitions) necessary to characterize a reference Cardiac Device implant procedure.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Detaljert beskrivelse
The purpose of the research is to establish the metrics (operational definitions) necessary to characterize a reference Cardiac Device implant procedure, to seek consensus from experienced device implanters on the appropriateness of the steps as well as errors identified, and to determine if such validated performance metrics are a valid assessment tool with the ability to discriminate between the performances of experienced and novice implanters.
These validated metrics will potentially serve as an educational and training tool to improve and quality assure Cardiac device implant training.
The steps involved in characterising a reference procedure are as follows:
- Define the implant procedure in quantifiable steps (already performed)
- Seek consensus and agreement by an independent panel on the steps (already done).
- Video record routinely performed device implants by experienced and novice physicians.
- Reviewing and scoring the video recorded procedures to verify that the metrics distinguish between a novice and an expert cardiac device performance.
Studietype
Registrering (Forventet)
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Prøvetakingsmetode
Studiepopulasjon
This is an observational and educational study only. Cardiac device implants routinely performed in clinical practice will be video-recorded.
The procedures will be scheduled as per normal and the clinical pathway and management of the patient and the operator will remain unchanged.
Beskrivelse
Inclusion Criteria:
Patients eligible for a cardiac device implant as per current European Society of Cardiology guidelines.
Exclusion Criteria:
Patient< 18 y of age. Patients unable to provide informed written consent for the study.
-
Studieplan
Hvordan er studiet utformet?
Designdetaljer
Kohorter og intervensjoner
Gruppe / Kohort |
Intervensjon / Behandling |
|---|---|
|
Novices
Novices: Trainee cardiologists implanting cardiac devices as per guidelines under supervision
|
Observation of performance to validate matrix
|
|
Experts
Experts: Device implanting cardiologists implanting cardiac devices as per guidelines
|
Observation of performance to validate matrix
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
The primary outcome measure is the comparison of the intra-operative performance of novices versus experts
Tidsramme: 6 months
|
The primary analysis will compare the intra-operative performance of novices versus experts. The three experienced cardiac device implanters will test the consented metrics by reviewing and scoring the video recorded procedures to verify that the metrics distinguish between a novice and an expert cardiac device performance. IRR will be considered to be acceptable if it is ≥ 0.8 The primary analysis will compare the intra-operative performance of novices versus experts. The three experienced cardiac device implanters will test the consented metrics by reviewing and scoring the video recorded procedures to verify that the metrics distinguish between a novice and an expert cardiac device performance. IRR will be considered to be acceptable if it is ≥ 0.8 |
6 months
|
Samarbeidspartnere og etterforskere
Samarbeidspartnere
Studierekorddatoer
Studer hoveddatoer
Studiestart (Forventet)
Primær fullføring (Forventet)
Studiet fullført (Forventet)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Andre studie-ID-numre
- 1189
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
IPD-planbeskrivelse
IPD-delingstidsramme
Tilgangskriterier for IPD-deling
IPD-deling Støtteinformasjonstype
- STUDY_PROTOCOL
- SEVJE
- ICF
- CSR
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
produkt produsert i og eksportert fra USA
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .