Periodontal Biocompatibility of Pediatric Crowns

20. mai 2026 oppdatert av: Sema Aydınoglu, Recep Tayyip Erdogan University Training and Research Hospital

Comparative Evaluation of Periodontal Biocompatibility of Pediatric Crowns Using Clinical Parameters and GCF Biomarkers

Different full-coverage crown materials are widely used in pediatric dentistry for the restoration of primary teeth with extensive substance loss. Since these restorations remain in close contact with gingival tissues for prolonged periods, they may influence periodontal health depending on their surface characteristics, marginal adaptation, and biological properties. The aim of this study was to evaluate the effects of stainless steel crowns (SSC), prefabricated zirconia crowns (PZC), and fiber-glass crowns (FGC) on periodontal health in children using both clinical periodontal parameters and gingival crevicular fluid (GCF) biomarkers, including IL-1β and MMP-8, within a split-mouth study design.

Studieoversikt

Studietype

Observasjonsmessig

Registrering (Faktiske)

21

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Barn

Tar imot friske frivillige

Ja

Prøvetakingsmetode

Sannsynlighetsprøve

Studiepopulasjon

children who applied for the dental treatment to the Faculty of Dentistry in Rize

Beskrivelse

Inclusion Criteria:

  • Children who were aged between 6 and 9 years
  • Children had a score of 3 or 4 on the Frankl Behavioral Scale
  • Children had an indication for full coronal restoration in the primary second molars in all the three quadrants
  • Presence of extensive or chronic carious lesions involving the pulp with radiographic scores ranging between 2 and 3
  • Presence of localized hypoplastic defects
  • Normal or non-resorbed interproximal bone levels, defined radiographically as a distance of no more than 2 mm between the interdental bone crest and the cementoenamel junction
  • Those where the root resorption level was blunt or the apex was rounded, and those where 1/4 of the root has been resorbed

Exclusion Criteria:

  • Children had any systemic disease
  • History of allergy to local anesthetic agents, nickel, or resin-based restorative materials
  • Extremely poor oral hygiene
  • Periodontal disease
  • Malocclusion

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Kohorter og intervensjoner

Gruppe / Kohort
Intervensjon / Behandling
Group 1
Teeth diagnosed with an indication for full coronal restoration and treated with stainless steel crown.

Clinical periodontal assessments were carried out for all participants at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) follow-up visits. The clinical periodontal status was assessed with the probing pocket depth (PPD), bleeding on probing (BOP), plaque index (PI), and gingival index (GI).

For each patient, GCF measurements and sample collection were performed at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) visits. MMP-8 and IL-1β analyses were performed on GCF samples by the enzyme-linked immunosorbent assay (ELISA).

Group 2
Teeth diagnosed with an indication for full coronal restoration and treated with prefabricated zirconia crown.

Clinical periodontal assessments were carried out for all participants at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) follow-up visits. The clinical periodontal status was assessed with the probing pocket depth (PPD), bleeding on probing (BOP), plaque index (PI), and gingival index (GI).

For each patient, GCF measurements and sample collection were performed at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) visits. MMP-8 and IL-1β analyses were performed on GCF samples by the enzyme-linked immunosorbent assay (ELISA).

Group 3
Teeth diagnosed with an indication for full coronal restoration and treated with fiber glass crown.

Clinical periodontal assessments were carried out for all participants at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) follow-up visits. The clinical periodontal status was assessed with the probing pocket depth (PPD), bleeding on probing (BOP), plaque index (PI), and gingival index (GI).

For each patient, GCF measurements and sample collection were performed at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) visits. MMP-8 and IL-1β analyses were performed on GCF samples by the enzyme-linked immunosorbent assay (ELISA).

Group 4
Healthy primary molars (control group)

Clinical periodontal assessments were carried out for all participants at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) follow-up visits. The clinical periodontal status was assessed with the probing pocket depth (PPD), bleeding on probing (BOP), plaque index (PI), and gingival index (GI).

For each patient, GCF measurements and sample collection were performed at baseline (T0), as well as during the third-month (T1) and sixth-month (T2) visits. MMP-8 and IL-1β analyses were performed on GCF samples by the enzyme-linked immunosorbent assay (ELISA).

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
assessment of probing pocket depth (PPD)
Tidsramme: From beginning to the end of treatment at 6 months
probing pocket depth (PPD) was measured the distance between the gingival margin and the deepest point of the sulcus. PPD was evaluated from six surfaces (mesiobuccal, midbuccal, distobuccal, mesiolingual/mesiopalatal, midlingual/midpalatal, and distolingual/distopalatal) of the teeth. The measurements were done utilizing a Williams periodontal probe.
From beginning to the end of treatment at 6 months
assessment of matrix metalloproteinase-8 (MMP-8) level in gingival crevicular fluid (GCF)
Tidsramme: in the sixth month (after sample collection was complete)
MMP-8 was performed on GCF samples by the enzyme-linked immunosorbent assay (ELISA) in the Medical Biochemistry Research and Application Laboratory of the Recep Tayyip Erdogan University Faculty of Medicine. Twenty-four hours before the assay procedure, the eppendorf tubes were removed from the deep freezer and allowed to thaw progressively at -20 °C followed by +4 °C. Prior to analysis, both the samples and assay reagents were equilibrated to room temperature (18-25 °C). Each GCF specimen was analyzed individually without combining the samples. The results were expressed in ng/mL (MMP-8).
in the sixth month (after sample collection was complete)
Assessment of bleeding on probing (BOP)
Tidsramme: From beginning to the end of treatment at 6 months
Bleeding on probing (BOP) scores were obtained from four surfaces (mesial, distal, buccal, and palatal/lingual) of the primary second molars. The measurements were done utilizing a Williams periodontal probe.
From beginning to the end of treatment at 6 months
Assessment of plaque index (PI)
Tidsramme: From beginning to the end of treatment at 6 months
Plaque index (PI) scores were obtained from four surfaces (mesial, distal, buccal, and palatal/lingual) of the primary second molars. The measurements were done utilizing a Williams periodontal probe.
From beginning to the end of treatment at 6 months
Assessment of Gingival index (GI)
Tidsramme: From beginning to the end of treatment at 6 months
Gingival index (GI) scores were obtained from four surfaces (mesial, distal, buccal, and palatal/lingual) of the primary second molars. The measurements were done utilizing a Williams periodontal probe.
From beginning to the end of treatment at 6 months
Assessment of interleukin-1 beta (IL-1β) level in gingival crevicular fluid (GCF)
Tidsramme: in the sixth month (after sample collection was complete)
In GCF samples taken from patients, IL-1β level was determined by enzyme-linked immunosorbent assay (ELISA) according to the manufacturer's instructions at the Medical Biochemistry Research and Application Laboratory of Recep Tayyip Erdoğan University Faculty of Medicine. Twenty-four hours before the assay procedure, the eppendorf tubes were removed from the deep freezer and allowed to thaw progressively at -20 °C followed by +4 °C. Prior to analysis, both the samples and assay reagents were equilibrated to room temperature (18-25 °C). Each GCF specimen was analyzed individually without combining the samples. The results were expressed in pg/mL (IL-1β).
in the sixth month (after sample collection was complete)

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

30. juni 2024

Primær fullføring (Faktiske)

30. desember 2025

Studiet fullført (Faktiske)

20. april 2026

Datoer for studieregistrering

Først innsendt

14. mai 2026

Først innsendt som oppfylte QC-kriteriene

20. mai 2026

Først lagt ut (Faktiske)

28. mai 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

28. mai 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

20. mai 2026

Sist bekreftet

1. mai 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • 2024/05 (Annen identifikator: Atatürk University Clinical Research Ethics Committee)

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .