- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07613658
3D-Printed Versus Band-and-Loop Versus Denovo Space Maintainers in Primary Dentition.
3D-Printed Custom Versus Conventional Band-and-Loop Versus Chairside Denovo Space Maintainers in the Primary Dentition: A Randomized Controlled Trial Protocol
Purpose of the Study When a child loses a "baby" molar early due to a cavity or injury, the surrounding teeth can shift into the empty space. This often blocks the permanent adult tooth from growing in correctly. To prevent this, dentists use a small metal device called a space maintainer.
This study aims to find out which of three different types of space maintainers lasts the longest, is most comfortable for the child, and is most efficient for the dental office to provide.
The Three Study Groups
Children in this study are randomly assigned to one of three groups:
- 3D-Printed Custom Group: The dentist takes a digital picture (scan) of the child's mouth instead of a traditional mold. A custom-fit appliance is then 3D-printed using a specialized, medical-grade clear material.
- Conventional Band-and-Loop Group: This is the traditional method. The dentist takes a physical mold of the teeth, which is sent to a laboratory. The child usually has to return for a second appointment a week later to have the metal appliance glued into place.
- Denovo Chairside Group: This uses a kit of pre-made metal parts. The dentist selects the best fit and assembles the appliance right at the chairside, allowing it to be placed during a single visit.
What is Being Measured?
Researchers are following the children for 12 months to track:
Survival: Which appliance stays glued in and doesn't break most effectively?
Time: How much time does the dentist spend making and fitting the appliance?
Comfort: How much discomfort or pain did the child feel during the process?
Health: Does the appliance cause any irritation to the gums or surrounding teeth?
Who Can Participate? The study includes children between the ages of 5 and 10 who have lost at least one primary (baby) molar early and need a space maintainer to protect their future adult smile.
Importance of This Research By comparing these three methods, this study helps dentists understand if newer technologies, like 3D printing or pre-made kits, are better or more convenient than the traditional lab-made metal loops used for decades. This information will help families choose the best treatment for their children.
Studieoversikt
Status
Detaljert beskrivelse
Clinical Workflow and Device Fabrication
The trial compares three distinct manufacturing and clinical delivery pathways for pediatric space maintenance:
3D-Printed Custom Workflow (Experimental Arm)
Data Acquisition: Digital impressions are captured using a high-precision intraoral scanner (3Shape TRIOS).
Design Phase: The STL files are imported into CAD software (exocad), where a custom space maintainer is designed with a specific focus on anatomical adaptation to the abutment tooth and the edentulous ridge.
Manufacturing: Appliances are fabricated via Stereolithography (SLA) using a Form 3B+ printer with BioMed Clear Resin. Post-processing includes a 20-minute isopropyl alcohol wash and 60 minutes of UV curing at 60°C to ensure biocompatibility and optimal mechanical properties.
Delivery: The printed appliance is bonded using a light-cured orthodontic adhesive.
Conventional Band-and-Loop Workflow (Active Comparator)
Clinical Phase: Traditional alginate impressions are taken and poured with dental stone to create a physical working model.
Laboratory Phase: A stainless steel band (3M Unitek) is fitted to the abutment tooth on the model. A 0.036-inch stainless steel wire is contoured to the ridge and silver-soldered to the band.
Delivery: The appliance is polished and cemented in a subsequent clinical appointment using glass ionomer cement.
- Denovo Chairside Workflow (Active Comparator)
Selection: A prefabricated kit (Denovo Dental) is used to select a band size that fits the abutment tooth.
Assembly: A pre-formed wire loop is selected and adjusted for length at the chairside. The loop is mechanically secured to the band using the system's specialized crimping and locking mechanism, eliminating the need for soldering or laboratory delays.
Delivery: The assembled appliance is cemented during the same appointment as the initial measurement.
Randomization and Standardization Participants are allocated 1:1:1 using a computer-generated randomization sequence. To ensure consistency, all clinical procedures-including tooth preparation, scanning, and cementation-are performed by a group of calibrated pediatric dentists following a standardized protocol. For the 3D-printed group, resin batches and printer calibration are monitored weekly to ensure material integrity.
Studietype
Registrering (Antatt)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiekontakt
- Navn: MURAD A ALRASHIDI, Pediatric Orthodontist
- Telefonnummer: +966 55 302 2773
- E-post: MU.ALRASHIDI@qu.edu.sa
Studiesteder
-
-
Al-Qassim Region
-
Buraidah, Al-Qassim Region, Saudi-Arabia, 52571
- Qassim University
-
Ta kontakt med:
- MURAD ALRASHIDI, BDS, MSC
- Telefonnummer: +966 55 302 2773
- E-post: MU.ALRASHIDI@qu.edu.sa
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
- Children aged 5 to 10 years
- Premature unilateral loss of at least one primary first or second molar
- Radiographically confirmed developing permanent successor at Nolla developmental stage 4 to 7
- Parent or legal guardian able and willing to provide written informed consent, and child able to provide age-appropriate assent
Exclusion Criteria:
- Systemic disease affecting bone metabolism or tooth development
- Clinically significant mesiodistal space loss at screening, defined as greater than 3 mm
- Poor oral hygiene precluding band placement, defined as a full-mouth plaque score greater than 50%
- Known allergy or hypersensitivity to stainless steel or resin components
- Current participation in another interventional clinical trial
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Forebygging
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: 3D-Printed Custom Space Maintainer
Participants in this arm receive a custom-designed space maintainer fabricated through a fully digital workflow.
This involves an intraoral scan (3Shape TRIOS) and CAD design (exocad).
The appliance is 3D-printed using stereolithography (SLA) technology (Formlabs Form 3B+) with BioMed Clear Resin, a biocompatible photopolymer.
The appliance is bonded to the abutment tooth using a light-cured orthodontic adhesive during a single or subsequent clinical visit.
|
A digitally designed, monolithic space maintainer.
The workflow involves an intraoral scan (3Shape TRIOS) and CAD design (exocad).
The device is fabricated using stereolithography (SLA) technology (Formlabs Form 3B+) with BioMed Clear Resin.
It is bonded to the abutment tooth using a light-cured orthodontic adhesive
|
|
Aktiv komparator: Conventional Band-and-Loop
This arm represents the current clinical reference standard.
Fabrication follows a traditional analog workflow beginning with an alginate impression and stone model.
A stainless steel band (3M Unitek) is fitted to the model, and a stainless steel wire (0.036-inch) is hand-contoured and silver-soldered to the band.
The completed appliance is polished and cemented using glass ionomer cement in a second clinical appointment.
|
The traditional clinical reference standard.
It is fabricated using an analog workflow: an alginate impression is taken to create a stone model, a stainless steel band (3M Unitek) is fitted to the model, and a 0.036-inch stainless steel wire is hand-contoured and silver-soldered to the band.
The appliance is polished and cemented with glass ionomer cement.
|
|
Aktiv komparator: Denovo Chairside Space Maintainer
This arm utilizes a prefabricated, chairside system (Denovo Dental) designed for single-visit delivery.
A pre-sized stainless steel band is selected and fitted directly to the patient's tooth.
A pre-formed wire loop is then adjusted for the appropriate span and mechanically secured to the band using a specialized crimping and locking tool, eliminating the need for laboratory soldering.
The appliance is cemented during the same appointment as the initial fitting.
|
A prefabricated, stainless steel space maintainer system (Denovo Dental) designed for immediate application.
A pre-sized band is selected and fitted directly to the patient's tooth.
A pre-formed wire loop is adjusted for length at the chairside and mechanically secured to the band using a specialized crimping and locking tool, requiring no laboratory soldering.
It is cemented during the initial appointment.
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Appliance Survival Rate
Tidsramme: At 12 months from baseline
|
This measures the clinical longevity and "success" of the appliance.
A "failure" is recorded if the appliance becomes completely or partially dislodged (cement failure), suffers a structural fracture, or causes significant soft-tissue trauma requiring its removal.
|
At 12 months from baseline
|
|
Space Maintenance Effectiveness:
Tidsramme: At 12 month from baseline
|
Measured as the change in the mesiodistal dimension of the extraction space (in millimeters).
Digital calipers or software will compare the initial space at baseline to the space remaining at the end of the study.
|
At 12 month from baseline
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Clinical and Laboratory Time (Efficiency)
Tidsramme: At baseline
|
Researchers will record the active working time (in minutes) for each stage of fabrication.
This includes chairside time (scanning or impressions and fitting) and laboratory time (3D printing and post-processing, manual soldering, or chairside assembly).
|
At baseline
|
|
Gingival Health (Löe and Silness Index):
Tidsramme: Baseline, at 6 months, and at 12 months.
|
A clinical assessment of the soft tissue surrounding the abutment tooth.
It will be scored from 0 (normal) to 3 (severe inflammation/bleeding) to determine if any material or design causes more irritation than others.
|
Baseline, at 6 months, and at 12 months.
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Hovedetterforsker: MURAD ALRASHIDI, BDS, MSC, Qassim University
Studierekorddatoer
Studer hoveddatoer
Studiestart (Antatt)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- 26-20-3
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
IPD-planbeskrivelse
IPD-delingstidsramme
Tilgangskriterier for IPD-deling
IPD-deling Støtteinformasjonstype
- STUDY_PROTOCOL
- SEVJE
- ICF
- ANALYTIC_CODE
- CSR
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
produkt produsert i og eksportert fra USA
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .