Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

3D-Printed Versus Band-and-Loop Versus Denovo Space Maintainers in Primary Dentition.

21 mei 2026 bijgewerkt door: Murad Alrashidi

3D-Printed Custom Versus Conventional Band-and-Loop Versus Chairside Denovo Space Maintainers in the Primary Dentition: A Randomized Controlled Trial Protocol

Purpose of the Study When a child loses a "baby" molar early due to a cavity or injury, the surrounding teeth can shift into the empty space. This often blocks the permanent adult tooth from growing in correctly. To prevent this, dentists use a small metal device called a space maintainer.

This study aims to find out which of three different types of space maintainers lasts the longest, is most comfortable for the child, and is most efficient for the dental office to provide.

The Three Study Groups

Children in this study are randomly assigned to one of three groups:

  1. 3D-Printed Custom Group: The dentist takes a digital picture (scan) of the child's mouth instead of a traditional mold. A custom-fit appliance is then 3D-printed using a specialized, medical-grade clear material.
  2. Conventional Band-and-Loop Group: This is the traditional method. The dentist takes a physical mold of the teeth, which is sent to a laboratory. The child usually has to return for a second appointment a week later to have the metal appliance glued into place.
  3. Denovo Chairside Group: This uses a kit of pre-made metal parts. The dentist selects the best fit and assembles the appliance right at the chairside, allowing it to be placed during a single visit.

What is Being Measured?

Researchers are following the children for 12 months to track:

Survival: Which appliance stays glued in and doesn't break most effectively?

Time: How much time does the dentist spend making and fitting the appliance?

Comfort: How much discomfort or pain did the child feel during the process?

Health: Does the appliance cause any irritation to the gums or surrounding teeth?

Who Can Participate? The study includes children between the ages of 5 and 10 who have lost at least one primary (baby) molar early and need a space maintainer to protect their future adult smile.

Importance of This Research By comparing these three methods, this study helps dentists understand if newer technologies, like 3D printing or pre-made kits, are better or more convenient than the traditional lab-made metal loops used for decades. This information will help families choose the best treatment for their children.

Studie Overzicht

Gedetailleerde beschrijving

Clinical Workflow and Device Fabrication

The trial compares three distinct manufacturing and clinical delivery pathways for pediatric space maintenance:

  1. 3D-Printed Custom Workflow (Experimental Arm)

    Data Acquisition: Digital impressions are captured using a high-precision intraoral scanner (3Shape TRIOS).

    Design Phase: The STL files are imported into CAD software (exocad), where a custom space maintainer is designed with a specific focus on anatomical adaptation to the abutment tooth and the edentulous ridge.

    Manufacturing: Appliances are fabricated via Stereolithography (SLA) using a Form 3B+ printer with BioMed Clear Resin. Post-processing includes a 20-minute isopropyl alcohol wash and 60 minutes of UV curing at 60°C to ensure biocompatibility and optimal mechanical properties.

    Delivery: The printed appliance is bonded using a light-cured orthodontic adhesive.

  2. Conventional Band-and-Loop Workflow (Active Comparator)

    Clinical Phase: Traditional alginate impressions are taken and poured with dental stone to create a physical working model.

    Laboratory Phase: A stainless steel band (3M Unitek) is fitted to the abutment tooth on the model. A 0.036-inch stainless steel wire is contoured to the ridge and silver-soldered to the band.

    Delivery: The appliance is polished and cemented in a subsequent clinical appointment using glass ionomer cement.

  3. Denovo Chairside Workflow (Active Comparator)

Selection: A prefabricated kit (Denovo Dental) is used to select a band size that fits the abutment tooth.

Assembly: A pre-formed wire loop is selected and adjusted for length at the chairside. The loop is mechanically secured to the band using the system's specialized crimping and locking mechanism, eliminating the need for soldering or laboratory delays.

Delivery: The assembled appliance is cemented during the same appointment as the initial measurement.

Randomization and Standardization Participants are allocated 1:1:1 using a computer-generated randomization sequence. To ensure consistency, all clinical procedures-including tooth preparation, scanning, and cementation-are performed by a group of calibrated pediatric dentists following a standardized protocol. For the 3D-printed group, resin batches and printer calibration are monitored weekly to ensure material integrity.

Studietype

Ingrijpend

Inschrijving (Geschat)

360

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

  • Naam: MURAD A ALRASHIDI, Pediatric Orthodontist
  • Telefoonnummer: +966 55 302 2773
  • E-mail: MU.ALRASHIDI@qu.edu.sa

Studie Locaties

    • Al-Qassim Region
      • Buraidah, Al-Qassim Region, Saoedi-Arabië, 52571
        • Qassim University
        • Contact:

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Kind

Accepteert gezonde vrijwilligers

Ja

Beschrijving

Inclusion Criteria:

  1. Children aged 5 to 10 years
  2. Premature unilateral loss of at least one primary first or second molar
  3. Radiographically confirmed developing permanent successor at Nolla developmental stage 4 to 7
  4. Parent or legal guardian able and willing to provide written informed consent, and child able to provide age-appropriate assent

Exclusion Criteria:

  1. Systemic disease affecting bone metabolism or tooth development
  2. Clinically significant mesiodistal space loss at screening, defined as greater than 3 mm
  3. Poor oral hygiene precluding band placement, defined as a full-mouth plaque score greater than 50%
  4. Known allergy or hypersensitivity to stainless steel or resin components
  5. Current participation in another interventional clinical trial

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Preventie
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: 3D-Printed Custom Space Maintainer
Participants in this arm receive a custom-designed space maintainer fabricated through a fully digital workflow. This involves an intraoral scan (3Shape TRIOS) and CAD design (exocad). The appliance is 3D-printed using stereolithography (SLA) technology (Formlabs Form 3B+) with BioMed Clear Resin, a biocompatible photopolymer. The appliance is bonded to the abutment tooth using a light-cured orthodontic adhesive during a single or subsequent clinical visit.
A digitally designed, monolithic space maintainer. The workflow involves an intraoral scan (3Shape TRIOS) and CAD design (exocad). The device is fabricated using stereolithography (SLA) technology (Formlabs Form 3B+) with BioMed Clear Resin. It is bonded to the abutment tooth using a light-cured orthodontic adhesive
Actieve vergelijker: Conventional Band-and-Loop
This arm represents the current clinical reference standard. Fabrication follows a traditional analog workflow beginning with an alginate impression and stone model. A stainless steel band (3M Unitek) is fitted to the model, and a stainless steel wire (0.036-inch) is hand-contoured and silver-soldered to the band. The completed appliance is polished and cemented using glass ionomer cement in a second clinical appointment.
The traditional clinical reference standard. It is fabricated using an analog workflow: an alginate impression is taken to create a stone model, a stainless steel band (3M Unitek) is fitted to the model, and a 0.036-inch stainless steel wire is hand-contoured and silver-soldered to the band. The appliance is polished and cemented with glass ionomer cement.
Actieve vergelijker: Denovo Chairside Space Maintainer
This arm utilizes a prefabricated, chairside system (Denovo Dental) designed for single-visit delivery. A pre-sized stainless steel band is selected and fitted directly to the patient's tooth. A pre-formed wire loop is then adjusted for the appropriate span and mechanically secured to the band using a specialized crimping and locking tool, eliminating the need for laboratory soldering. The appliance is cemented during the same appointment as the initial fitting.
A prefabricated, stainless steel space maintainer system (Denovo Dental) designed for immediate application. A pre-sized band is selected and fitted directly to the patient's tooth. A pre-formed wire loop is adjusted for length at the chairside and mechanically secured to the band using a specialized crimping and locking tool, requiring no laboratory soldering. It is cemented during the initial appointment.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Appliance Survival Rate
Tijdsspanne: At 12 months from baseline
This measures the clinical longevity and "success" of the appliance. A "failure" is recorded if the appliance becomes completely or partially dislodged (cement failure), suffers a structural fracture, or causes significant soft-tissue trauma requiring its removal.
At 12 months from baseline
Space Maintenance Effectiveness:
Tijdsspanne: At 12 month from baseline
Measured as the change in the mesiodistal dimension of the extraction space (in millimeters). Digital calipers or software will compare the initial space at baseline to the space remaining at the end of the study.
At 12 month from baseline

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Clinical and Laboratory Time (Efficiency)
Tijdsspanne: At baseline
Researchers will record the active working time (in minutes) for each stage of fabrication. This includes chairside time (scanning or impressions and fitting) and laboratory time (3D printing and post-processing, manual soldering, or chairside assembly).
At baseline
Gingival Health (Löe and Silness Index):
Tijdsspanne: Baseline, at 6 months, and at 12 months.
A clinical assessment of the soft tissue surrounding the abutment tooth. It will be scored from 0 (normal) to 3 (severe inflammation/bleeding) to determine if any material or design causes more irritation than others.
Baseline, at 6 months, and at 12 months.

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Sponsor

Onderzoekers

  • Hoofdonderzoeker: MURAD ALRASHIDI, BDS, MSC, Qassim University

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

1 juni 2026

Primaire voltooiing (Geschat)

1 juni 2027

Studie voltooiing (Geschat)

1 juli 2027

Studieregistratiedata

Eerst ingediend

12 mei 2026

Eerst ingediend dat voldeed aan de QC-criteria

21 mei 2026

Eerst geplaatst (Werkelijk)

29 mei 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

29 mei 2026

Laatste update ingediend die voldeed aan QC-criteria

21 mei 2026

Laatst geverifieerd

1 mei 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

JA

Beschrijving IPD-plan

The investigators will share the de-identified individual participant data that underlie the results reported in the final publication. This includes primary survival data (time-to-failure), gingival index scores, and recorded fabrication times.

IPD-tijdsbestek voor delen

Data will become available 6 months after the primary manuscript is published in a peer-reviewed journal.

IPD-toegangscriteria voor delen

Data will be made available to qualified academic researchers. For researchers who provide a methodologically sound proposal to achieve the aims of the approved proposal (e.g., meta-analysis or validation of digital orthodontic workflows). Data requestors must sign a formal Data Access Agreement to ensure the privacy of the pediatric participants. Requests should be directed to the Principal Investigator.

IPD delen Ondersteunend informatietype

  • LEERPROTOCOOL
  • SAP
  • ICF
  • ANALYTIC_CODE
  • MVO

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Ja

product vervaardigd in en geëxporteerd uit de V.S.

Ja

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren