Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

C-LIFT Efficacy in Patients With Obstructive Sleep Apnea (EOSA)

2. september 2026 oppdatert av: Ata Murat Kaynar

Efficacy Testing of Active Head Tilt Chin-Lift Positioning (C-LIFT) Device in Patients With Obstructive Sleep Apnea

The goal of this clinical trial is to evaluate the efficacy of the C-Lift Device as a non-invasive treatment for Sleep Disordered Breathing (SDB) within the population of adults diagnosed with moderate to severe Obstructive Sleep Apnea (OSA), who are not currently being treated with a Continuous Positive Airway Pressure (CPAP) device or other intervention.

This study aims to answer 2 main questions: "Will C-Lift demonstrate a qualitative improvement in a participant's perception/description of their sleep-quality?" And, "Will wearing the C-Lift Device overnight show a quantitative improvement in a participant's oxygen saturation?"

Studieoversikt

Status

Har ikke rekruttert ennå

Intervensjon / Behandling

Detaljert beskrivelse

The validated "Standford Sleepiness Scale", Richards-Campbell Sleep Questionnaire, and "PROMIS- Sleep Disturbance Short Form-8a" (also referred to as the "DSM-5-TR Level 2- Sleep Disturbance- Adult Measure") will be used pre- and post-intervention to establish the participant's perception of their sleep-quality during the overnight study compared to their baseline. A custom "C-Lift Efficacy Questionnaire" will be given post-intervention to document the participant's experience with the device and assess their ability to tolerate wearing the device. The quantitative impact of the C-Lift Device will be measured by the Apnea-Hypopnea Index (AHI), Oxygen Desaturation Index (ODI), and the hypoxic burden of the participant recorded during the overnight study-study.

Studietype

Intervensjonell

Registrering (Antatt)

10

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studiesteder

    • Pennsylvania
      • Pittsburgh, Pennsylvania, Forente stater, 15213
        • The Center for Sleep and Cardiovascular Outcomes Research (C-SCOR) Sleep Laboratory
        • Ta kontakt med:
        • Ta kontakt med:

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Nei

Beskrivelse

Inclusion Criteria:

  • Diagnosis of moderate to severe OSA (≥16 AHI events per hour)
  • Previously failed/refused CPAP
  • Not currently/actively participating in treatment for OSA

Exclusion Criteria:

  • Diagnosis of mild OSA (AHI<15 events per hour)
  • Received treatment for OSA in the 2-weeks prior to the sleep-study EX: CPAP, other oral device
  • Received prior surgical treatment for OSA EX: hypoglossal nerve stimulation (NOT including Tonsillectomy)
  • Diagnosis of comorbid sleep disorder EX: Insomnia
  • History of other sleep-disordered breathing EX: central sleep apnea, hypoventilation syndrome
  • History of cervical spine injury/surgery
  • Currently receiving oxygen therapy
  • Baseline oxygen saturation <90%
  • Currently pregnant
  • History of substance abuse
  • Neck circumference >20 inches
  • Regular use of medications which can impact sleep-disordered breathing or related symptoms.

EX: opioids, benzodiazepines, gabapentin, antipsychotics, amphetamines or other stimulants.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Intervensjonsmodell: Enkeltgruppeoppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: C-Lift
Participants will wear the C-Lift during sleep for one night in a sleep lab.
The Head-Tilt, Chin-Lift Positioning Device (C-Lift) is embedded with a variety of sensors to detect SDB events and OSA symptoms. Audible snoring, sounds of gasping, or decreased oxygen saturation will trigger the cushioned lining the neck brace, to inflate/deflate, as needed, to open the airway and maintain stable breathing.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Apnea-Hypopnea Index (AHI)
Tidsramme: The device will be worn for the duration of the sleep-study, approximately 8 hours.

The Apnea-Hypopnea Index (AHI) represents the number of SDB Events, like pauses in breathing (apnea) or airway obstructions (hypopnea), per hour of sleep. The AHI Score indicates the severity of the OSA symptoms, ranging from mild (AHI: <15 events per hour), to moderate (15-30 events per hour), to severe (>30 events per hour).

A lower AHI score indicates fewer SDB events and a better quality of sleep. A higher an AHI score, means more frequent breathing interruptions, lower quality sleep and severe symptoms of OSA.

Investigators will compare AHI after wearing the device and the participant's AHI prior to wearing the device.

The device will be worn for the duration of the sleep-study, approximately 8 hours.
Participant's Description of Outcomes
Tidsramme: This outcome measure will be obtained from subject feedback provided after the subject has worn the device for the duration of the sleep-study, which will last approximately 8 hours.
Qualitative description of outcomes on efficacy, and comfort. (i.e. improved symptoms of sleep apnea) Standford Sleepiness Scale, Richards-Campbell Sleep Questionnaire, and "PROMIS- Sleep Disturbance Short Form-8a" (also referred to as the "DSM-5-TR Level 2- Sleep Disturbance- Adult Measure") will be used pre- and post-intervention to establish the participant's perception of their sleep-quality during the overnight study compared to their baseline. A custom "C-Lift Efficacy Questionnaire" will be given post-intervention to document the participant's experience with the device and assess their ability to tolerate
This outcome measure will be obtained from subject feedback provided after the subject has worn the device for the duration of the sleep-study, which will last approximately 8 hours.

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Hovedetterforsker: Ata M Kaynar, MD, MPH, University of Pittsburgh

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

1. januar 2027

Primær fullføring (Antatt)

1. april 2027

Studiet fullført (Antatt)

1. januar 2029

Datoer for studieregistrering

Først innsendt

12. august 2026

Først innsendt som oppfylte QC-kriteriene

2. september 2026

Først lagt ut (Faktiske)

8. september 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

8. september 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

2. september 2026

Sist bekreftet

1. september 2026

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Ja

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere