Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Real-World Performance and Safety of Apneal Dx for Sleep Apnea Screening (APNEAL-PMCF)

3. september 2026 oppdatert av: Mitral

Real-world Evaluation of the Clinical Performance and Safety of Apneal Dx for the Screening and Aid in the Diagnosis of Obstructive Sleep Apnea-hypopnea Syndrome in Adults: a Post-market Clinical Follow-up Study

Sleep apnea-hypopnea syndrome (SAHS) is a frequent and largely under-diagnosed sleep-related breathing disorder. Adult prevalence is estimated between 9% and 38%. Untreated SAHS increases cardiometabolic and neurocognitive risk. Reference diagnostic methods (in-lab polysomnography and ambulatory ventilatory polygraphy) have limited capacity, which delays care.

Apneal Dx is a Class IIa software as a medical device (CE-marked 10 June 2026). It measures cardiorespiratory sleep activity using the sensors of a standard smartphone worn on the chest, with no additional sensor, to screen for and aid in the diagnosis of adult obstructive sleep apnea-hypopnea syndrome at home.

This study is a non-interventional, prospective, real-world post-market clinical follow-up (PMCF) of Apneal Dx used within its intended purpose in routine care. It does not add any examination, visit, randomisation or change to patient management. Data are collected from automatic device logs and optional in-app questionnaires completed by patients and healthcare professionals. The study covers France, Spain, Italy, the United Kingdom and Germany. There is no investigational site and no principal investigator.

Studieoversikt

Status

Har ikke rekruttert ennå

Detaljert beskrivelse

OBJECTIVES

This PMCF study addresses residual evidence gaps after CE marking of Apneal Dx, under MDR Articles 61(11), 83, 84 and 86 and Annex XIV Part B, in support of a strategy based on Article 61(10).

Primary objectives:

(A) Demonstrate end-to-end technical performance in the unsupervised home environment and detect safety-relevant failure modes.

(B) Confirm concordance between the Apneal Dx AHI severity category and the healthcare professional's final clinical diagnosis obtained through the routine care pathway.

(C) Quantify real-world false positive and false negative rates at AHI thresholds of 5, 15 and 30 events per hour.

Secondary objectives:

(D) Care-pathway time indicators (time to consultation, diagnosis and treatment).

(E) How device outputs are used in clinical decisions. (F) Diagnostic performance against polysomnography (PSG) and ventilatory polygraphy (PG), when those tests have already been performed in routine care.

(G) Real-world screening utility, conditions of use and usability.

METHODS

Design: observational, prospective, single-cohort, longitudinal real-world data collection. Non-comparative; no randomisation; no blinding; no imposed follow-up visit. Target enrolment: 400 evaluable patients (estimated). Individual participation lasts up to 24 months (questionnaires at 6, 12 and 24 months after the first recording). Study period: 04 September 2026 to 10 June 2031 (57 months, aligned with the CE certificate cycle).

No intervention is assigned by the protocol. Apneal Dx is used under normal conditions of use and within its intended purpose. A PSG or PG result is collected only if the test has already been performed in the usual care pathway; the study never prescribes, prompts, schedules or funds a confirmatory test.

Data sources: (1) automatic technical metadata from the device (session duration, signal quality, processing events, error codes, software version); (2) healthcare professional questionnaire (H01-H14) on the HCP web platform; (3) patient questionnaire (P01-P12) in the mobile application. No medical records, no SNDS, no biospecimens, no linkage with an external database.

Setting: home and routine clinical practice. Decentralised collection with no investigational site, no participating institution and no principal investigator. The sponsor headquarters (Mitral SAS, Charenton-le-Pont, France) is declared as the single administrative location. Participants may reside in France, Spain, Italy, the United Kingdom or Germany.

Ethics: no ethics committee is territorially or institutionally competent in the absence of a site. Human subjects protection review is therefore recorded as not required. Participation follows a dedicated in-app information notice, distinct from the terms of use, and a voluntary in-app agreement. A permanent right to object applies.

Analysis: descriptive (point estimates and 95% Wilson confidence intervals, distributions, weighted Cohen kappa for concordance, sensitivity and specificity by AHI threshold, median delays). No superiority or non-inferiority hypothesis test. No multiplicity adjustment. Missing data are not imputed.

Studietype

Observasjonsmessig

Registrering (Antatt)

400

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studiesteder

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Nei

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

Adults with sleep complaints using the CE-marked Apneal Dx software as a medical device within its intended purpose, at home and in routine clinical practice, in France, Spain, Italy, Great Britain and Germany. The entire eligible active user base is solicited; no selection, sampling, stratification or quota is applied.

Beskrivelse

Inclusion Criteria:

  • Aged 18 years or over
  • Uses Apneal Dx within its intended purpose in France, Spain, Italy, the United Kingdom or Germany
  • Has completed at least one recording generating a night report
  • Has received the study information notice
  • Has given the in-app agreement to take part

Exclusion Criteria:

  • Under 18 years of age
  • Adult under legal protection

Both exclusion criteria are applied by design through an application eligibility rule.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Kohorter og intervensjoner

Gruppe / Kohort
Apneal Dx users
Adults aged 18 years or over with sleep complaints, using Apneal Dx within its intended purpose at home in routine care, who have completed at least one recording generating a night report.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Patient recording success rate
Tidsramme: Continuous, from study start through study completion (up to 57 months)
Proportion of interpretable nights among all attempted recordings, derived from automatic device logging.
Continuous, from study start through study completion (up to 57 months)
Concordance between Apneal Dx severity category and the physician's final clinical diagnosis
Tidsramme: Up to 24 months after the first recording, per participant
Weighted Cohen's kappa and proportion of exact agreement between the AHI severity category produced by Apneal Dx (normal, mild, moderate, severe) and the final clinical diagnosis reported by the healthcare professional, in participants with a documented reference test (PSG or PG) obtained through routine care.
Up to 24 months after the first recording, per participant
Real-world false positive and false negative rates by AHI threshold
Tidsramme: Up to 24 months after the first recording, per participant
False positive and false negative rates at AHI thresholds of 5, 15 and 30 events per hour, against the documented reference test result, with 95% Wilson confidence intervals.
Up to 24 months after the first recording, per participant

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Time to consultation
Tidsramme: Up to 24 months after the first recording
Median number of days between the Apneal Dx night report and the first consultation with a healthcare professional.
Up to 24 months after the first recording
Time to diagnosis
Tidsramme: Up to 24 months after the first recording
Median number of days between the Apneal Dx night report and the reference sleep test (PSG or PG) performed in routine care.
Up to 24 months after the first recording
Time to treatment
Tidsramme: Up to 24 months after the first recording
Median number of days between the reference sleep test and treatment initiation.
Up to 24 months after the first recording
Distribution of clinical decisions following the Apneal report
Tidsramme: Up to 24 months after the first recording
Distribution of clinical decisions taken following the Apneal Dx report, by Apneal severity category.
Up to 24 months after the first recording
Agreement with PSG and with ventilatory polygraphy
Tidsramme: Up to 24 months after the first recording
Agreement of Apneal Dx with PSG and with ventilatory polygraphy, stratified by reference test type and severity, in participants with a documented routine-care reference test.
Up to 24 months after the first recording
Healthcare professional rating of Apneal Dx reliability
Tidsramme: Up to 24 months after the first recording
Proportion of healthcare professionals rating Apneal Dx as reliable (score 4 or 5 on a 1-5 Likert scale).
Up to 24 months after the first recording
Usability: navigation ease and instruction clarity
Tidsramme: 6 months after the first recording
Distribution of navigation ease and instruction clarity scores (1-5 Likert scales) reported by patients.
6 months after the first recording

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Sponsor

Etterforskere

  • Studieleder: Guillaume Cathelain, Mitral SAS

Publikasjoner og nyttige lenker

Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.

Generelle publikasjoner

  • Evaluation of the Clinical Performance of Apneal, a Medical Device on Smartphone, for Sleep Apnea-hypopnea Syndrome Diagnosis (EASY). ClinicalTrials.gov Identifier: NCT06474143.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

1. september 2026

Primær fullføring (Antatt)

1. juni 2031

Studiet fullført (Antatt)

1. juni 2031

Datoer for studieregistrering

Først innsendt

3. september 2026

Først innsendt som oppfylte QC-kriteriene

3. september 2026

Først lagt ut (Faktiske)

9. september 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

9. september 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

3. september 2026

Sist bekreftet

1. september 2026

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

produkt produsert i og eksportert fra USA

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .