Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Real-World Performance and Safety of Apneal Dx for Sleep Apnea Screening (APNEAL-PMCF)

3 września 2026 zaktualizowane przez: Mitral

Real-world Evaluation of the Clinical Performance and Safety of Apneal Dx for the Screening and Aid in the Diagnosis of Obstructive Sleep Apnea-hypopnea Syndrome in Adults: a Post-market Clinical Follow-up Study

Sleep apnea-hypopnea syndrome (SAHS) is a frequent and largely under-diagnosed sleep-related breathing disorder. Adult prevalence is estimated between 9% and 38%. Untreated SAHS increases cardiometabolic and neurocognitive risk. Reference diagnostic methods (in-lab polysomnography and ambulatory ventilatory polygraphy) have limited capacity, which delays care.

Apneal Dx is a Class IIa software as a medical device (CE-marked 10 June 2026). It measures cardiorespiratory sleep activity using the sensors of a standard smartphone worn on the chest, with no additional sensor, to screen for and aid in the diagnosis of adult obstructive sleep apnea-hypopnea syndrome at home.

This study is a non-interventional, prospective, real-world post-market clinical follow-up (PMCF) of Apneal Dx used within its intended purpose in routine care. It does not add any examination, visit, randomisation or change to patient management. Data are collected from automatic device logs and optional in-app questionnaires completed by patients and healthcare professionals. The study covers France, Spain, Italy, the United Kingdom and Germany. There is no investigational site and no principal investigator.

Przegląd badań

Szczegółowy opis

OBJECTIVES

This PMCF study addresses residual evidence gaps after CE marking of Apneal Dx, under MDR Articles 61(11), 83, 84 and 86 and Annex XIV Part B, in support of a strategy based on Article 61(10).

Primary objectives:

(A) Demonstrate end-to-end technical performance in the unsupervised home environment and detect safety-relevant failure modes.

(B) Confirm concordance between the Apneal Dx AHI severity category and the healthcare professional's final clinical diagnosis obtained through the routine care pathway.

(C) Quantify real-world false positive and false negative rates at AHI thresholds of 5, 15 and 30 events per hour.

Secondary objectives:

(D) Care-pathway time indicators (time to consultation, diagnosis and treatment).

(E) How device outputs are used in clinical decisions. (F) Diagnostic performance against polysomnography (PSG) and ventilatory polygraphy (PG), when those tests have already been performed in routine care.

(G) Real-world screening utility, conditions of use and usability.

METHODS

Design: observational, prospective, single-cohort, longitudinal real-world data collection. Non-comparative; no randomisation; no blinding; no imposed follow-up visit. Target enrolment: 400 evaluable patients (estimated). Individual participation lasts up to 24 months (questionnaires at 6, 12 and 24 months after the first recording). Study period: 04 September 2026 to 10 June 2031 (57 months, aligned with the CE certificate cycle).

No intervention is assigned by the protocol. Apneal Dx is used under normal conditions of use and within its intended purpose. A PSG or PG result is collected only if the test has already been performed in the usual care pathway; the study never prescribes, prompts, schedules or funds a confirmatory test.

Data sources: (1) automatic technical metadata from the device (session duration, signal quality, processing events, error codes, software version); (2) healthcare professional questionnaire (H01-H14) on the HCP web platform; (3) patient questionnaire (P01-P12) in the mobile application. No medical records, no SNDS, no biospecimens, no linkage with an external database.

Setting: home and routine clinical practice. Decentralised collection with no investigational site, no participating institution and no principal investigator. The sponsor headquarters (Mitral SAS, Charenton-le-Pont, France) is declared as the single administrative location. Participants may reside in France, Spain, Italy, the United Kingdom or Germany.

Ethics: no ethics committee is territorially or institutionally competent in the absence of a site. Human subjects protection review is therefore recorded as not required. Participation follows a dedicated in-app information notice, distinct from the terms of use, and a voluntary in-app agreement. A permanent right to object applies.

Analysis: descriptive (point estimates and 95% Wilson confidence intervals, distributions, weighted Cohen kappa for concordance, sensitivity and specificity by AHI threshold, median delays). No superiority or non-inferiority hypothesis test. No multiplicity adjustment. Missing data are not imputed.

Typ studiów

Obserwacyjny

Zapisy (Szacowany)

400

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Lokalizacje studiów

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

Adults with sleep complaints using the CE-marked Apneal Dx software as a medical device within its intended purpose, at home and in routine clinical practice, in France, Spain, Italy, Great Britain and Germany. The entire eligible active user base is solicited; no selection, sampling, stratification or quota is applied.

Opis

Inclusion Criteria:

  • Aged 18 years or over
  • Uses Apneal Dx within its intended purpose in France, Spain, Italy, the United Kingdom or Germany
  • Has completed at least one recording generating a night report
  • Has received the study information notice
  • Has given the in-app agreement to take part

Exclusion Criteria:

  • Under 18 years of age
  • Adult under legal protection

Both exclusion criteria are applied by design through an application eligibility rule.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Apneal Dx users
Adults aged 18 years or over with sleep complaints, using Apneal Dx within its intended purpose at home in routine care, who have completed at least one recording generating a night report.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Patient recording success rate
Ramy czasowe: Continuous, from study start through study completion (up to 57 months)
Proportion of interpretable nights among all attempted recordings, derived from automatic device logging.
Continuous, from study start through study completion (up to 57 months)
Concordance between Apneal Dx severity category and the physician's final clinical diagnosis
Ramy czasowe: Up to 24 months after the first recording, per participant
Weighted Cohen's kappa and proportion of exact agreement between the AHI severity category produced by Apneal Dx (normal, mild, moderate, severe) and the final clinical diagnosis reported by the healthcare professional, in participants with a documented reference test (PSG or PG) obtained through routine care.
Up to 24 months after the first recording, per participant
Real-world false positive and false negative rates by AHI threshold
Ramy czasowe: Up to 24 months after the first recording, per participant
False positive and false negative rates at AHI thresholds of 5, 15 and 30 events per hour, against the documented reference test result, with 95% Wilson confidence intervals.
Up to 24 months after the first recording, per participant

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Time to consultation
Ramy czasowe: Up to 24 months after the first recording
Median number of days between the Apneal Dx night report and the first consultation with a healthcare professional.
Up to 24 months after the first recording
Time to diagnosis
Ramy czasowe: Up to 24 months after the first recording
Median number of days between the Apneal Dx night report and the reference sleep test (PSG or PG) performed in routine care.
Up to 24 months after the first recording
Time to treatment
Ramy czasowe: Up to 24 months after the first recording
Median number of days between the reference sleep test and treatment initiation.
Up to 24 months after the first recording
Distribution of clinical decisions following the Apneal report
Ramy czasowe: Up to 24 months after the first recording
Distribution of clinical decisions taken following the Apneal Dx report, by Apneal severity category.
Up to 24 months after the first recording
Agreement with PSG and with ventilatory polygraphy
Ramy czasowe: Up to 24 months after the first recording
Agreement of Apneal Dx with PSG and with ventilatory polygraphy, stratified by reference test type and severity, in participants with a documented routine-care reference test.
Up to 24 months after the first recording
Healthcare professional rating of Apneal Dx reliability
Ramy czasowe: Up to 24 months after the first recording
Proportion of healthcare professionals rating Apneal Dx as reliable (score 4 or 5 on a 1-5 Likert scale).
Up to 24 months after the first recording
Usability: navigation ease and instruction clarity
Ramy czasowe: 6 months after the first recording
Distribution of navigation ease and instruction clarity scores (1-5 Likert scales) reported by patients.
6 months after the first recording

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Śledczy

  • Dyrektor Studium: Guillaume Cathelain, Mitral SAS

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Publikacje ogólne

  • Evaluation of the Clinical Performance of Apneal, a Medical Device on Smartphone, for Sleep Apnea-hypopnea Syndrome Diagnosis (EASY). ClinicalTrials.gov Identifier: NCT06474143.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 września 2026

Zakończenie podstawowe (Szacowany)

1 czerwca 2031

Ukończenie studiów (Szacowany)

1 czerwca 2031

Daty rejestracji na studia

Pierwszy przesłany

3 września 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

3 września 2026

Pierwszy wysłany (Rzeczywisty)

9 września 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

9 września 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

3 września 2026

Ostatnia weryfikacja

1 września 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

produkt wyprodukowany i wyeksportowany z USA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj