Comparison Evaluation of the Accuracy of Two Digital Technologies of Measuring Sagittal Condylar Inclination in Edentulous Patients

16. november 2026 oppdatert av: Fuming He
  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At the time of definitive impression taking, mandibular movement trajectories were captured and left and right sagittal condylar inclination (SCI) values were recorded using the Zebris electronic facebow and the Shining intraoral and facial scanning system, respectively. All measurements were performed by a single experienced operator. Each measurement method was repeated three times per participant, and the average value was calculated for analysis.

Studieoversikt

Status

Har ikke rekruttert ennå

Detaljert beskrivelse

  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients meeting the inclusion criteria were screened among candidates who had received implant-supported full-arch provisional restorations and required definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At definitive impression taking, mandibular movement trajectories were recorded, and left and right sagittal condylar inclination (SCI) values were acquired using the Zebris electronic facebow and the Shining intraoral and facial scanning system. All measurements were performed by a single experienced operator. The SCI values were automatically generated by the built-in software of each system. For each participant, every measurement modality was repeated three times, and the mean value was adopted. A visual analogue scale (VAS) questionnaire was used to assess patient comfort during the measurement procedures.

Studietype

Observasjonsmessig

Registrering (Antatt)

20

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

  • Navn: Fuming He
  • Telefonnummer: +8613516817697
  • E-post: hfm@zju.edu.cn

Studer Kontakt Backup

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Ja

Kjønn som er kvalifisert for studier

Alle

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028.

Beskrivelse

Inclusion Criteria:

  1. Patients aged 18years or older
  2. Ability to undergo full-arch implant-supported rehabilitation and receive an implant-supported full-arch acrylic resin provisional prosthesis within 24 h after surgery
  3. Good oral hygiene conditions
  4. The patient is able to understand and actively cooperate with the treatment process, and has signed informed consent

Exclusion Criteria:

  1. Unable to tolerate transplant surgery (due to systemic diseases such as heart disease, hypertension, etc., long history of drug use)
  2. Pregnancy or gestation period
  3. Smokes more than 10 cigarettes a day
  4. The presence of physical defects that may affect transplant surgery
  5. Patients with immune dysfunction, including patients with HIV infection
  6. Local inflammation, including untreated periodontitis
  7. A history of head and neck chemotherapy within a year, or a history of intravenous bisphosphonate use
  8. A habit of severe grinding or clenching of the teeth
  9. Poor oral hygiene or poor compliance
  10. There are benign or malignant tumors in the culture area
  11. Osteoporosis such as severe osteoporosis

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Observasjonsmodeller: COHORT
  • Tidsperspektiver: PROSPECTIVE

Kohorter og intervensjoner

Gruppe / Kohort
Zebris electronic facebow group

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

SHINING 3D intraoral scan-facial scan fusion multimodal workflow group

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan fusion multimodal workflow.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
sagittal condylar inclination (SCI)
Tidsramme: From enrollment

The sagittal condylar inclination (SCI) values were automatically exported by the built-in software of both systems.

From enrollment

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
patient satisfaction and comfort
Tidsramme: From enrollment

Patient comfort during measurement procedures was assessed using a visual analogue scale (VAS). A 10-cm horizontal line was drawn, anchored at the two ends by the descriptors "most comfortable" (10 cm) and "least comfortable" (0 cm), with no intermediate markings. Immediately after each measurement modality, participants completed the VAS rating to prevent carry-over effects between procedures. A standard ruler was used by the investigator to measure the distance from the left end (0 mm) of the line to the mark made by the participant.

From enrollment

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Sponsor

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

26. november 2026

Primær fullføring (Antatt)

31. august 2028

Studiet fullført (Antatt)

30. november 2028

Datoer for studieregistrering

Først innsendt

16. november 2026

Først innsendt som oppfylte QC-kriteriene

16. november 2026

Først lagt ut (Faktiske)

20. november 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

20. november 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

16. november 2026

Sist bekreftet

1. august 2026

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere