Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Comparison Evaluation of the Accuracy of Two Digital Technologies of Measuring Sagittal Condylar Inclination in Edentulous Patients

16 november 2026 uppdaterad av: Fuming He
  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At the time of definitive impression taking, mandibular movement trajectories were captured and left and right sagittal condylar inclination (SCI) values were recorded using the Zebris electronic facebow and the Shining intraoral and facial scanning system, respectively. All measurements were performed by a single experienced operator. Each measurement method was repeated three times per participant, and the average value was calculated for analysis.

Studieöversikt

Status

Har inte rekryterat ännu

Detaljerad beskrivning

  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients meeting the inclusion criteria were screened among candidates who had received implant-supported full-arch provisional restorations and required definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At definitive impression taking, mandibular movement trajectories were recorded, and left and right sagittal condylar inclination (SCI) values were acquired using the Zebris electronic facebow and the Shining intraoral and facial scanning system. All measurements were performed by a single experienced operator. The SCI values were automatically generated by the built-in software of each system. For each participant, every measurement modality was repeated three times, and the mean value was adopted. A visual analogue scale (VAS) questionnaire was used to assess patient comfort during the measurement procedures.

Studietyp

Observationell

Inskrivning (Beräknad)

20

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

  • Namn: Fuming He
  • Telefonnummer: +8613516817697
  • E-post: hfm@zju.edu.cn

Studera Kontakt Backup

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Ja

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028.

Beskrivning

Inclusion Criteria:

  1. Patients aged 18years or older
  2. Ability to undergo full-arch implant-supported rehabilitation and receive an implant-supported full-arch acrylic resin provisional prosthesis within 24 h after surgery
  3. Good oral hygiene conditions
  4. The patient is able to understand and actively cooperate with the treatment process, and has signed informed consent

Exclusion Criteria:

  1. Unable to tolerate transplant surgery (due to systemic diseases such as heart disease, hypertension, etc., long history of drug use)
  2. Pregnancy or gestation period
  3. Smokes more than 10 cigarettes a day
  4. The presence of physical defects that may affect transplant surgery
  5. Patients with immune dysfunction, including patients with HIV infection
  6. Local inflammation, including untreated periodontitis
  7. A history of head and neck chemotherapy within a year, or a history of intravenous bisphosphonate use
  8. A habit of severe grinding or clenching of the teeth
  9. Poor oral hygiene or poor compliance
  10. There are benign or malignant tumors in the culture area
  11. Osteoporosis such as severe osteoporosis

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Observationsmodeller: COHORT
  • Tidsperspektiv: PROSPECTIVE

Kohorter och interventioner

Grupp / Kohort
Zebris electronic facebow group

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

SHINING 3D intraoral scan-facial scan fusion multimodal workflow group

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan fusion multimodal workflow.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
sagittal condylar inclination (SCI)
Tidsram: From enrollment

The sagittal condylar inclination (SCI) values were automatically exported by the built-in software of both systems.

From enrollment

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
patient satisfaction and comfort
Tidsram: From enrollment

Patient comfort during measurement procedures was assessed using a visual analogue scale (VAS). A 10-cm horizontal line was drawn, anchored at the two ends by the descriptors "most comfortable" (10 cm) and "least comfortable" (0 cm), with no intermediate markings. Immediately after each measurement modality, participants completed the VAS rating to prevent carry-over effects between procedures. A standard ruler was used by the investigator to measure the distance from the left end (0 mm) of the line to the mark made by the participant.

From enrollment

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Sponsor

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

26 november 2026

Primärt slutförande (Beräknad)

31 augusti 2028

Avslutad studie (Beräknad)

30 november 2028

Studieregistreringsdatum

Först inskickad

16 november 2026

Först inskickad som uppfyllde QC-kriterierna

16 november 2026

Första postat (Faktisk)

20 november 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

20 november 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

16 november 2026

Senast verifierad

1 augusti 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera