REPRISE EDGE 29 mm EU Study
REPRISE EDGE 29 mm EU Study: REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE 29 mm Valve - Evaluation of Safety and Performance
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Typ studiów
Faza
- Nie dotyczy
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dziecko
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Subject has documented calcific native aortic valve stenosis with an initial aortic valve area (AVA) of ≤1.0 cm2 (or AVA index of ≤0.6 cm2/m2) and either a mean pressure gradient ≥40 mm Hg or a jet velocity ≥4 m/s, as measured by echocardiography and/or invasive hemodynamics.
- Subject has a documented aortic annulus size of ≥27 mm and ≤29 mm based on the site's assessment of pre-procedure diagnostic imaging (and confirmed by the Case Review Committee [CRC]).
- Subject has symptomatic aortic valve stenosis with NYHA Functional Class ≥ II.
There is agreement by the heart team (which must include a site investigator interventionalist and a site investigator cardiac surgeon) that subject is at high or extreme operative risk for surgical valve replacement (see Note 5 below for definitions of extreme and high risk, the required level of surgical assessment, and CRC confirmation) and that TAVR is appropriate.
Additionally, subject has at least one of the following:
- Society of Thoracic Surgeons (STS) score ≥8% -OR-
If STS <8, subject has at least one of the following conditions:
- Hostile chest
- Porcelain aorta
- Severe pulmonary hypertension (>60 mmHg)
- Prior chest radiation therapy
- Coronary artery bypass graft(s) at risk with re-operation
- Severe lung disease (need for supplemental oxygen, FEV1 <50% of predicted, DLCO <60%, or other evidence of severe pulmonary dysfunction)
- Neuromuscular disease that creates risk for mechanical ventilation or rehabilitation after surgical aortic valve replacement
- Orthopedic disease that creates risk for rehabilitation after surgical aortic valve replacement
- Childs Class A or B liver disease (subjects with Childs Class C disease are not eligible for inclusion in this trial)
- Frailty as indicated by at least one of the following: 5-meter walk >6 seconds, Katz ADL score of 3/6 or less, body mass index <21, wheelchair bound, unable to live independently
- Age ≥90 years
- Other evidence that subject is at high or extreme risk for surgical valve replacement (CRC must confirm agreement with site heart team that subject meets high or extreme risk definition)
Note 5: Risk of operative mortality and morbidity must be assessed via an in-person evaluation by a site cardiac surgeon and must be confirmed by the CRC (which must include an experienced cardiac surgeon). Extreme operative risk and high operative risk are defined as follows:
Extreme Operative Risk: Predicted operative mortality or serious, irreversible morbidity risk ≥50% at 30 days.
High Operative Risk: Predicted operative mortality or serious, irreversible morbidity risk ≥15% at 30 days.
- Heart team (which must include a cardiac interventionalist and an experienced cardiac surgeon) agrees that the subject is likely to benefit from valve replacement.
- Subject (or legal representative) understands the study requirements and the treatment procedures, and provides written informed consent.
- Subject, family member and/or legal representative agree(s) and subject is capable of returning to the study hospital for all required scheduled follow up visits.
Exclusion Criteria:
- Subject has a congenital unicuspid or bicuspid aortic valve.
- Subject with an acute myocardial infarction within 30 days of the index procedure (defined as Q-wave MI or non-Q-wave MI with total CK elevation ≥ twice normal in the presence of CK-MB elevation and/or troponin level elevation).
- Subject has had a cerebrovascular accident or transient ischemic attack within the past 6 months prior to study enrollment.
- Subject has end-stage renal disease or has GFR <20 (based on Cockcroft-Gault formula).
- Subject has a pre-existing prosthetic aortic or mitral valve.
- Subject has severe (4+) aortic, tricuspid, or mitral regurgitation.
- Subject has a need for emergency surgery for any reason.
- Subject has a history of endocarditis within 6 months of index procedure or evidence of an active systemic infection or sepsis.
- Subject has echocardiographic evidence of new intra-cardiac vegetation or intraventricular or paravalvular thrombus requiring intervention.
- Subject has Hgb <9 g/dL, platelet count <50,000 cells/mm3 or >700,000 cells/mm3, or white blood cell count <1,000 cells/mm3.
- Subject requires chronic anticoagulation therapy after the implant procedure and cannot be treated with warfarin (other anticoagulants are not permitted in the first month) for at least 1 month concomitant with either aspirin or clopidogrel.
- Subject has had a gastrointestinal bleed requiring hospitalization or transfusion within the past 3 months, or has other clinically significant bleeding diathesis or coagulopathy that would preclude treatment with required antiplatelet regimen, or will refuse transfusions.
- Subject has known hypersensitivity to contrast agents that cannot be adequately pre-medicated, or has known hypersensitivity to aspirin, all P2Y12 inhibitors, heparin, nickel, tantalum, titanium, or polyurethanes.
- Subject has a life expectancy of less than 12 months due to non-cardiac, comorbid conditions based on the assessment of the investigator at the time of enrollment.
- Subject has hypertrophic obstructive cardiomyopathy.
- Subject has any therapeutic invasive cardiac or vascular procedure within 30 days prior to the index procedure (except for balloon aortic valvuloplasty and pacemaker implantation, which are allowed).
- Subject has untreated coronary artery disease, which in the opinion of the treating physician, is clinically significant and requires revascularization.
- Subject has severe left ventricular dysfunction with ejection fraction <20%.
- Subject is in cardiogenic shock or has hemodynamic instability requiring inotropic support or mechanical support devices.
- Subject has severe vascular disease that would preclude safe access (e.g., aneurysm with thrombus that cannot be crossed safely, marked tortuosity, significant narrowing of the abdominal aorta, severe unfolding of the thoracic aorta, or symptomatic carotid or vertebral disease).
- Subject has thick (>5 mm) protruding or ulcerated atheroma in the aortic arch.
- Subject has arterial access that is not acceptable for the LOTUS Edge delivery system and its compatible Lotus Introducer as defined in the Instructions For Use.
- Subject has current problems with substance abuse (e.g., alcohol, etc.).
- Subject is participating in another investigational drug or device study that has not reached its primary endpoint.
- Subject has untreated conduction system disorder (e.g., Type II second degree atrioventricular block) that in the opinion of the treating physician is clinically significant and requires a pacemaker implantation (based on the latest available ESC guidelines). Enrollment is permissible after permanent pacemaker implantation.
- Subject has severe incapacitating dementia.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: 29 mm LOTUS Edge™
|
Transcatheter aortic valve replacement
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
|---|---|
|
Mean aortic valve pressure gradient as measured by echocardiography and assessed by an independent core laboratory.
Ramy czasowe: 30 days post-procedure
|
30 days post-procedure
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Oczekiwany)
Zakończenie podstawowe (Oczekiwany)
Ukończenie studiów (Oczekiwany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- S2351
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .