Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Comparison of High-Flow Nasal Cannula and Tight Face Mask for Maintaining Oxygenation During Rapid Sequence Induction

22 lipca 2026 zaktualizowane przez: Shandana Gul, Khyber Teaching Hospital

Comparison of the Effectiveness of High-Flow Oxygen Cannula Versus Tight Face Mask in Maintaining Oxygenation During Rapid Sequence Induction

This prospective randomized controlled trial aims to compare the effectiveness of High-Flow Nasal Cannula (HFNC) versus Tight Face Mask (TFM) in maintaining oxygenation during rapid sequence induction (RSI) for endotracheal intubation in adult patients. Participants will be randomly assigned in a 1:1 ratio to receive either HFNC or TFM for preoxygenation before induction of anesthesia. The primary outcome is the lowest peripheral oxygen saturation (SpO₂) recorded from induction until successful endotracheal intubation. Secondary outcomes include the incidence of oxygen desaturation (<90%), duration of apnea, duration of laryngoscopy, intubation time, number of intubation attempts, and peri-intubation complications. The study will determine whether HFNC provides superior oxygenation compared with conventional face mask preoxygenation during RSI and may contribute to improving airway management protocols and patient safety.

Przegląd badań

Szczegółowy opis

Rapid sequence induction (RSI) is the preferred technique for securing the airway in patients at risk of aspiration. Despite standardized airway management protocols, hypoxemia during the apneic period remains one of the most frequent and clinically important complications of RSI. Oxygen desaturation may lead to serious adverse events including cardiac arrhythmias, hemodynamic instability, cardiac arrest, neurological injury, and increased mortality. Effective preoxygenation before induction is therefore essential to maximize oxygen reserves and prolong safe apnea time.

Conventional preoxygenation is commonly performed using a tight face mask delivering 100% oxygen. Although this method is widely accepted, oxygen delivery is interrupted when the face mask is removed for laryngoscopy, potentially reducing oxygen reserves during prolonged intubation attempts. High-Flow Nasal Cannula (HFNC) delivers heated and humidified oxygen at high flow rates with a high inspired oxygen fraction while allowing continuous oxygen administration throughout laryngoscopy and apnea. HFNC also generates low-level positive airway pressure and facilitates clearance of upper airway dead space, which may improve oxygenation during rapid sequence induction.

Previous randomized trials and systematic reviews have produced inconsistent findings regarding the comparative effectiveness of HFNC and conventional face mask preoxygenation. Some studies have demonstrated prolonged safe apnea time and improved oxygenation with HFNC, whereas others have shown similar oxygen saturation between both techniques. Additional randomized controlled trials are required to determine whether HFNC provides clinically meaningful advantages in adult patients undergoing rapid sequence induction.

This single-center, prospective, parallel-group, randomized controlled trial will be conducted at the Department of Anesthesiology, Khyber Teaching Hospital, Peshawar. Eligible adult patients requiring rapid sequence induction for endotracheal intubation in the operating room, emergency department, or intensive care unit will be enrolled after providing informed consent. Participants will be randomly assigned in a 1:1 ratio to receive either High-Flow Nasal Cannula or Tight Face Mask preoxygenation using a computer-generated randomization sequence with allocation concealment through sequentially numbered, opaque, sealed envelopes.

Patients allocated to the intervention group will receive heated, humidified oxygen via High-Flow Nasal Cannula at the protocol-defined flow rate and fraction of inspired oxygen before induction and throughout laryngoscopy until successful endotracheal intubation. Participants allocated to the control group will receive conventional preoxygenation using a tightly fitting face mask delivering 100% oxygen according to standard institutional practice until induction of anesthesia.

The primary outcome will be the lowest peripheral oxygen saturation (SpO₂) recorded from induction until successful tracheal intubation. Secondary outcome measures will include the incidence of oxygen desaturation below 90%, duration of apnea, duration of laryngoscopy, time required for successful intubation, first-pass intubation success, number of intubation attempts, and peri-intubation adverse events including hypotension, arrhythmias, aspiration, and cardiac arrest.

Data will be collected prospectively using standardized case report forms by trained investigators. Statistical analyses will follow the intention-to-treat principle. Continuous variables will be compared using the independent-samples t-test or Mann-Whitney U test as appropriate, whereas categorical variables will be compared using the Chi-square test or Fisher's exact test. A two-sided p-value of less than 0.05 will be considered statistically significant.

The results of this trial are expected to provide high-quality evidence regarding the optimal preoxygenation strategy during rapid sequence induction and may contribute to improved airway management protocols and reduction of peri-intubation hypoxemia in adult patients.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

290

Faza

  • Nie dotyczy

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Opis

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Patients requiring rapid sequence induction (RSI) for endotracheal intubation in the operating room, emergency department, or intensive care unit.
  • Patients in whom both high-flow nasal cannula (HFNC) and tight face mask preoxygenation are technically feasible.
  • Patients (or their legally authorized representatives, when applicable) able to provide written informed consent.

Exclusion Criteria:

  • Patients requiring immediate crash intubation without sufficient time for preoxygenation.
  • Patients with facial deformities, upper airway obstruction, or other conditions preventing the use of either HFNC or a tight face mask.
  • Known contraindications or hypersensitivity to medications used for rapid sequence induction.
  • Pregnant women.
  • Patients younger than 18 years of age.
  • Patients with do-not-intubate (DNI) orders.
  • Patients already intubated or mechanically ventilated before enrollment.
  • Patients who underwent endotracheal intubation within the previous 24 hours.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: High-Flow Nasal Cannula (HFNC)
Participants randomized to this arm will receive preoxygenation using a heated, humidified high-flow nasal cannula delivering oxygen at 60 L/min with an FiO₂ of 100% for 3 minutes before rapid sequence induction. The HFNC will remain in place during induction and laryngoscopy until successful endotracheal intubation to provide continuous oxygenation throughout the apneic period.
Participants assigned to this intervention will receive preoxygenation using a heated, humidified high-flow nasal cannula delivering oxygen at a flow rate of 60 L/min with an inspired oxygen fraction (FiO₂) of 1.0 (100%) for 3 minutes before rapid sequence induction. Oxygen delivery will be continued throughout the apneic period and laryngoscopy until successful endotracheal intubation.
Inne nazwy:
  • High-Flow Nasal Oxygen (HFNO)
Aktywny komparator: Tight Face Mask (TFM)

Participants randomized to this arm will receive standard preoxygenation using a tightly fitting anesthesia face mask delivering 100% oxygen at 15 L/min for 3 minutes before rapid sequence induction. The face mask will be removed immediately before laryngoscopy according to routine clinical practice.

These arm titles and descriptions are appropriate for ClinicalTrials.gov registration. The next step will be to link each arm to its corresponding Device Intervention (HFNC and Tight Face Mask).

Participants assigned to this intervention will receive standard preoxygenation using a tightly fitting anesthesia face mask delivering 100% oxygen at a flow rate of 15 L/min for 3 minutes before rapid sequence induction. The face mask will be removed immediately before laryngoscopy in accordance with standard clinical practice.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Ramy czasowe
Lowest Peripheral Oxygen Saturation (SpO₂) During Rapid Sequence Induction
Ramy czasowe: Periprocedural (during rapid sequence induction, from induction of anesthesia until successful endotracheal intubation; approximately 5 minutes).
Periprocedural (during rapid sequence induction, from induction of anesthesia until successful endotracheal intubation; approximately 5 minutes).

Miary wyników drugorzędnych

Miara wyniku
Ramy czasowe
Incidence of Oxygen Desaturation
Ramy czasowe: Periprocedural (during rapid sequence induction, from induction of anesthesia until successful endotracheal intubation; approximately 5 minutes).
Periprocedural (during rapid sequence induction, from induction of anesthesia until successful endotracheal intubation; approximately 5 minutes).

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 sierpnia 2026

Zakończenie podstawowe (Szacowany)

20 lutego 2027

Ukończenie studiów (Szacowany)

20 lutego 2027

Daty rejestracji na studia

Pierwszy przesłany

16 lipca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

22 lipca 2026

Pierwszy wysłany (Rzeczywisty)

23 lipca 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

23 lipca 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

22 lipca 2026

Ostatnia weryfikacja

1 lipca 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 015/DME/KMC

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .