Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Pulmonary Function, Respiratory Muscle Strength, Lung Age, Balance, And Quality Of Life In Paralympic Athletes

1 sierpnia 2026 zaktualizowane przez: Seda Yıldız, Halic University

Investigation Of Pulmonary Function, Respiratory Muscle Strength, Lung Age, Balance, And Quality Of Life In Paralympic Athletes: A Cross-Sectional Study

Paralympic athletes actively participate in many sports despite their physical limitations and continue to develop both individually and athletically. Assessing the physical and functional capacities of these athletes is important in terms of performance and health. This study aimed to examine the relationships between respiratory function, respiratory muscle strength, lung age, balance, and quality of life in Paralympic athletes. Additionally, it was evaluated whether there were significant differences in these parameters according to disability type and gender.

The study included 24 Paralympic athletes from the disciplines of athletics, swimming, archery, and wheelchair basketball. Participants had various orthopeadic and neurological disability types, including cerebral palsy, lower extremity amputation, spinal cord injuries (C5-T6 and T7 and below), hypotonia, poliomyelitis, spina bifida, brachial plexus injury, and short stature. Respiratory function was assessed using forced vital capacity (FVC), forced expiratory volume in one second (FEV₁), FEV₁/FVC ratio, peak expiratory flow (PEF), and forced expiratory flow (FEF25-75%); respiratory muscle strength was assessed using maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP). Lung age was calculated based on FEV₁ values, balance was measured using the Modified Functional Reach Test, and quality of life was determined using the Short Form (SF-36) questionnaire. Significant correlations were found between parameters. Based on the study results, supporting respiratory muscle strength in Paralympic athletes may be an important goal in rehabilitation and training programs to support respiratory function, lung age, and quality of life parameters.

Przegląd badań

Status

Zakończony

Typ studiów

Obserwacyjny

Zapisy (Rzeczywisty)

24

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły

Akceptuje zdrowych ochotników

Nie

Metoda próbkowania

Próbka prawdopodobieństwa

Badana populacja

Paralympic athletes who has been playing their sports minimum 1 year participated in the study.

Opis

Inclusion Criteria:

  • Being between 18-50 years of age
  • Being registered with any of the sports federations in Turkey and being a licensed paralympic athlete for at least 1 year (
  • Having a lower extremity or upper extremity amputation or having permanent injuries as determined by the International Paralympic Committee

Exclusion Criteria:

  • Lack of consent to participate in the study.
  • Having undergone surgery within the last 6 months.
  • Having had a respiratory tract infection within the three weeks prior to the evaluations
  • FEV1/FVC < 0.7

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Forced expiratory volume in the first second (FEV1) (L)
Ramy czasowe: 4 months

Pulmonary function (Forced expiratory volume in the first second FEV1)) was evaluated with a portable spirometer, COSMED Pony FX® (COSMED S.r.l., Italy) and measurements were performed according to European Respiratory Society standards.

Considering that dizziness may occur during forced expiration, measurements were made while individuals were in a sitting position. While participants were sitting in a comfortable position in a chair with a backrest, nose clip was attached and they were asked to bite the mouth teeth and close their lips in a way that did not allow air to escape. The tests were performed at least 3 times by the participants and care was taken to ensure that the expiration time was at least 6 seconds and the plateau time was 1 second. Due to the device software that records all three data, it saved the average of the two best data and processed it as a value.

4 months

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Forced vital capacity (FVC) (L)
Ramy czasowe: 4 months
Pulmonary function ((Forced vital capacity (FVC )) was evaluated with a portable spirometer.
4 months
FEV1 / FVC (%)
Ramy czasowe: 4 months
Pulmonary function (FEV1 / FVC) was evaluated with a spirometer.
4 months
Peak flow rate (PEF) (L/s)
Ramy czasowe: 4 months
Pulmonary function (Peak flow rate (PEF)) was evaluated with a spirometer.
4 months
Flow rate 25-75% of forced expiratory volume (FEF 25-75%) (L/s)
Ramy czasowe: 4 months
Pulmonary function (Flow rate 25-75% of forced expiratory volume (FEF 25-75%)) was evaluated with a spirometer.
4 months
Maximal expiratory pressure (MEP) (L)
Ramy czasowe: 4 months
The MEP which shows respiratory muscle strength was evaluated using a portable mouth pressure measuring device based on European Respiratory Society criteria.
4 months
Maximal inspiratory pressure (MIP) (L)
Ramy czasowe: 4 months
The MIP which shows respiratory muscle strength was evaluated using a portable mouth pressure measuring device based on European Respiratory Society criteria.
4 months
Balance
Ramy czasowe: 4 months
Balance was measured using the Modified Functional Reach Test
4 months
Quality of Life
Ramy czasowe: 4 months
Quality of life was determined using the Short Form-36 (SF-36) Health Survey that contains 36 questions and produces scores for eight health related quality of life domains. Each domain is transformed to a 0-100 scale. Higher scores represents better health status while lower stores represents poor health status.
4 months
Lung Age
Ramy czasowe: 4 months
Lung age was calculated based on FEV₁ values. For male: Lung age (years)=(2.87×height in cm×0.394)-(31.25×FEV1 in L)-39.375 For females: Lung age (years)=(3.56×height in cm×0.394)-(40×FEV1 in L)-77.280
4 months

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 grudnia 2024

Zakończenie podstawowe (Rzeczywisty)

31 maja 2025

Ukończenie studiów (Rzeczywisty)

30 czerwca 2025

Daty rejestracji na studia

Pierwszy przesłany

26 czerwca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

1 sierpnia 2026

Pierwszy wysłany (Rzeczywisty)

6 sierpnia 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

6 sierpnia 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

1 sierpnia 2026

Ostatnia weryfikacja

1 sierpnia 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • Paralympic_Athlete

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

TAK

Opis planu IPD

Quality of life and balance results can be shared.

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj