- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07844252
A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy (mAInstream)
A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy: an International Multicenter Randomized Controlled Trial
To overcome non-neoplastic polyp (NNP) resections, computer-aided diagnosis (CADx) systems have been developed. In a meta-analysis, the performance of CADx systems was superior to endoscopists. The proportion of incorrect predictions could be significantly reduced with CADx assistance. It was reported that autonomous AI prediction could achieve an agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value compared to the histology as gold standard. Lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced under the 'diagnose-and-leave' strategy.
Nevertheless, almost all existing literature reporting the efficacy of CADx were simulated studies and focused on the diagnostic accuracy (i.e. all polyps were ultimately resected for histopathology). There is a lack of real-world data with hard clinical endpoints to support its implementation. A recent RCT compared leave-in-situ and resect-all strategy with real-time CADx in both arms. Using ADR as the surrogate marker, it was shown that the leave-in-situ strategy with CADx support was non-inferior. The major limitations of this RCT were that: i) CADx were activated in both arms - the pure CADx effect could not be demonstrated; ii) 'resect-all' strategy was not a real-world practice especially for diminutive rectosigmoid polyps; iii) the interaction and decision making between AI and human was not documented and uncertain.
A well-designed RCT is warranted to evaluate the pure CADx effect on reducing NNP resections (enhance treatment efficacy) while maintaining the benchmark of ADR (safe implementation). In addition, AI-measured metrics may objectively validate the procedural quality for performance tracking and auditing purposes. If the above points are proven, AI-assisted colonoscopy would become the 'mainstream' in CRC prevention.
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
In a meta-analysis, the performance of CADx systems was superior to endoscopists, with pooled sensitivity and specificity of 92.3% and 89.8% respectively. The proportion of incorrect predictions could be significantly reduced by 12% with CADx assistance. It was reported that autonomous AI prediction could achieve a 91.5% agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value of 97.6% compared to the histology as gold standard. 82% of lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced by 6.9-18.9% under the 'diagnose-and-leave' strategy.
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Li
- Numer telefonu: +85246572604
- E-mail: venusli@cuhk.edu.hk
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Aged 45-85 years old;
- Undergoing elective colonoscopy for screening, surveillance or diagnostic indication;
- Informed consented.
Exclusion Criteria:
- Contraindication for colonoscopy (e.g. intestinal obstruction);
- Contraindication for polypectomy (e.g. active gastrointestinal bleeding, uninterrupted anticoagulants);
- Prior surgical resection of colon;
- High-risk group of CRC (e.g. personal history of CRC, familial polyposis syndrome, inflammatory bowel disease);
- Advanced comorbidity (defined as American Society of Anesthesiologists grade 4 or above).
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Ekranizacja
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Brak interwencji: CADe
In the CADe mode, an alert box will be automatically displayed on the screen when a suspicious lesion is detected. |
|
|
Aktywny komparator: CADe/CADx
In this arm, when a suspicious lesion is detected, an alert box and a prediction on the histopathology (neoplastic vs non-neoplastic) will be generated by the underlying AI algorithm and displayed. |
A novel all-in-one AI system for colonoscopy (GI Genius™ ColonPro™, version 4.0.0, Medtronic plc, Minneapolis, United States) is developed as a pre-installed software in a plug-in device which is compatible with all existing endoscopes and processors. |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Primary endpoints (1)
Ramy czasowe: 3 years
|
Superiority: neoplastic to non-neoplastic polyp (NNP) ratio, defined as the total number of neoplastic polyps divided by the number of NNP per group. (indicating the treatment efficacy) |
3 years
|
|
Primary Endpoints (2)
Ramy czasowe: 3 years
|
Non-inferiority: adenoma detection rate (ADR), defined as proportion of subjects with at least one histologically confirmed adenoma in the colonoscopies. (indicating the safety margin for implementation) |
3 years
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- NTEC-CREC-2026.416
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .