Subcutaneous Implantable Cardioverter-defibrillator (S-ICD) Eligibility Over Time in Arrhythmogenic Cardiomyopathy

1 października 2026 zaktualizowane przez: Luciana Sacilotto, University of Sao Paulo

Evaluation of Subcutaneous Implantable Cardioverter-defibrillator Eligibility in Patients With Arrhythmogenic Right and Left Ventricular Cardiomyopathy: a Prospective Longitudinal Pilot Cohort Study

The goal of this observational study is to learn whether adults with arrhythmogenic cardiomyopathy, an inherited heart muscle disease that can cause dangerous heart rhythms, remain eligible for a subcutaneous implantable cardioverter-defibrillator (S-ICD) over time.

An S-ICD is a device placed under the skin, outside the heart, that can stop life-threatening heart rhythms with an electric shock. Before an S-ICD is implanted, a screening test checks whether the heart's electrical signals, recorded from the skin of the chest, are suitable for the device to work correctly. Because arrhythmogenic cardiomyopathy is a progressive disease, these signals may change over time, and a patient who passes the screening today may not pass it later.

The main questions it aims to answer are:

  • Does S-ICD eligibility remain stable over 18 months in patients with arrhythmogenic cardiomyopathy?
  • Are changes in eligibility related to changes in the electrocardiogram during follow-up?

Researchers will compare patients with arrhythmogenic cardiomyopathy with patients with Brugada syndrome, a condition in which the S-ICD is commonly used, and with people without structural heart disease.

Participants will:

  • Undergo S-ICD screening using the manufacturer's screening algorithm, with electrodes placed on the chest skin, at the start of the study and again at 6, 12 and 18 months
  • Continue their usual medical care

No device will be implanted as part of this study. Any decision to implant a defibrillator will be made by each patient's care team, independently of the study.

Przegląd badań

Status

Rekrutacyjny

Szczegółowy opis

Background: Arrhythmogenic cardiomyopathy (ACM) is a genetic, progressive heart muscle disease characterized by fibrofatty replacement of the myocardium, which predisposes patients to ventricular arrhythmias, heart failure and sudden cardiac death. The disease was initially described as a predominantly right ventricular condition (arrhythmogenic right ventricular cardiomyopathy, ARVC), diagnosed by the 2010 Task Force criteria, but left ventricular and biventricular involvement are now recognized, were proposed to incorporate left ventricular manifestations (arrhythmogenic left ventricular cardiomyopathy, ALVC). In high-risk patients, an implantable cardioverter-defibrillator (ICD) is recommended for the prevention of sudden cardiac death.

The subcutaneous ICD (S-ICD) is an entirely extravascular alternative that avoids transvenous leads and their long-term complications. However, S-ICD candidates must undergo pre-implant surface electrocardiogram (ECG) screening to ensure appropriate sensing and to reduce the risk of inappropriate shocks due to T-wave oversensing. Because ACM is progressive, its characteristic depolarization and repolarization abnormalities (such as T-wave inversion, epsilon waves, low QRS voltage and conduction delay) may change over time and affect S-ICD eligibility after an initially favorable screening. Data on the performance and long-term eligibility of the S-ICD in this population remain scarce.

Study design: This is a prospective, longitudinal, single-center pilot cohort study conducted at the Arrhythmia Clinical Unit of the Heart Institute (InCor), Hospital das Clínicas, University of São Paulo Medical School, Brazil. The study includes three groups of 30 participants each: patients with ACM (study group); patients with Brugada syndrome, a condition in which the S-ICD is commonly indicated (reference group); and individuals without structural heart disease on transthoracic echocardiography (control group).

Study procedures: After informed consent, S-ICD eligibility is assessed using the LATITUDE programmer (Boston Scientific) and the manufacturer's screening algorithm, with surface ECG electrodes placed in the standard screening positions on the chest. Skin preparation may include shaving of chest hair and cleaning with alcohol. The screening is the only study procedure and is repeated at 6, 12 and 18 months after the baseline assessment, regardless of whether a device has been implanted. The study does not involve device implantation, device supply or any change in clinical management; implantation decisions remain at the discretion of each patient's care team.

Statistical analysis: Continuous variables will be described as means and standard deviations or medians and interquartile ranges, and categorical variables as absolute and relative frequencies. The proportion of patients eligible for the S-ICD at baseline and at each follow-up visit will be estimated with 95% confidence intervals and compared using logistic regression. Differences in the number of eligible sensing vectors between time points will be assessed by paired t-test or Wilcoxon signed-rank test, as appropriate, and eligibility across electrode positions will be compared using logistic regression for repeated measures. Factors associated with eligibility and loss of eligibility will be explored using Student's t-test or Mann-Whitney test for continuous variables and Pearson's chi-square or Fisher's exact test for categorical variables. Exploratory multivariable logistic regression models may be fitted, considering the limited sample size, with results reported as odds ratios and 95% confidence intervals. A two-sided significance level of 5% will be adopted.

Typ studiów

Obserwacyjny

Zapisy (Szacowany)

90

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Lokalizacje studiów

    • São Paulo
      • São Paulo, São Paulo, Brazylia, 05403-900
        • Rekrutacyjny
        • Heart Institute
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat i starsze (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Wszystko

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

Adults followed at the Arrhythmia Clinical Unit of the Heart Institute (InCor), Hospital das Clínicas, University of São Paulo Medical School, São Paulo, Brazil, in three groups: patients with arrhythmogenic right or left ventricular cardiomyopathy; patients with Brugada syndrome, a condition in which the subcutaneous ICD is commonly indicated (reference group); and individuals without structural heart disease on transthoracic echocardiography (control group).

Opis

Arrhythmogenic cardiomyopathy group

Inclusion Criteria:

  • Age 18 years or older
  • Diagnosis of arrhythmogenic right ventricular cardiomyopathy according to the updated 2010 Task Force criteria, or arrhythmogenic left ventricular cardiomyopathy according to the Padua criteria
  • Risk stratification for primary prevention of sudden cardiac death using the ARVC risk calculator (<5% = low risk; 5% to 10% = intermediate risk; >10% = high risk) or the 2015 International Task Force consensus; or secondary prevention (documented ventricular tachycardia or resuscitated cardiac arrest)

Exclusion Criteria:

  • Ventricular pacing by an artificial pacemaker
  • Heart transplantation
  • Refusal to sign the informed consent form
  • Comorbidities with a life expectancy of less than 1 year (e.g., advanced malignancy)

Brugada syndrome reference group

Inclusion Criteria:

  • Age 18 years or older
  • Type 1 Brugada ECG pattern, spontaneous or drug-induced

Exclusion Criteria:

  • Ventricular pacing by an artificial pacemaker
  • Heart transplantation
  • Refusal to sign the informed consent form
  • Comorbidities with a life expectancy of less than 1 year (e.g., advanced malignancy)

Control group

Inclusion Criteria:

  • Age 18 years or older
  • No structural heart disease, defined by a transthoracic echocardiogram with all parameters within normal reference values

Exclusion Criteria:

  • Structural heart disease on transthoracic echocardiography
  • Ventricular pacing by an artificial pacemaker
  • Heart transplantation
  • Refusal to sign the informed consent form
  • Comorbidities with a life expectancy of less than 1 year (e.g., advanced malignancy)

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Modele obserwacyjne: COHORT
  • Perspektywy czasowe: PROSPECTIVE

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
Arrhythmogenic cardiomyopathy

Adults with arrhythmogenic right ventricular cardiomyopathy (2010 Task Force criteria) or arrhythmogenic left ventricular cardiomyopathy (Padua criteria), with an indication for an implantable cardioverter-defibrillator for primary or secondary prevention of sudden cardiac death, followed at the Arrhythmia Clinical Unit of InCor.

Surface ECG screening for subcutaneous implantable cardioverter-defibrillator eligibility using the manufacturer's screening algorithm, performed at baseline and at 6, 12 and 18 months. No device is implanted as part of the study.

Brugada syndrome (reference group)

Adults with type 1 Brugada ECG pattern, spontaneous or drug-induced, a condition in which the subcutaneous ICD is commonly indicated.

Surface ECG screening for subcutaneous implantable cardioverter-defibrillator eligibility using the manufacturer's screening algorithm, performed at baseline and at 6, 12 and 18 months. No device is implanted as part of the study.

Control group

Adults without structural heart disease, defined by a normal transthoracic echocardiogram.

Surface ECG screening for subcutaneous implantable cardioverter-defibrillator eligibility using the manufacturer's screening algorithm, performed at baseline and at 6, 12 and 18 months. No device is implanted as part of the study.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Stability of subcutaneous ICD eligibility over 18 months
Ramy czasowe: Baseline, 6, 12 and 18 months

Proportion of patients with arrhythmogenic cardiomyopathy who are eligible for a subcutaneous implantable cardioverter-defibrillator at each assessment, and proportion of those eligible at baseline who remain eligible during follow-up. Eligibility is determined by surface ECG screening using the manufacturer's screening algorithm.

Baseline, 6, 12 and 18 months

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Association between ECG changes and subcutaneous ICD eligibility at 18 months
Ramy czasowe: Baseline to 18 months

Correlation between changes in surface ECG parameters during follow-up and subcutaneous ICD eligibility at 18 months in patients with arrhythmogenic cardiomyopathy.

Baseline to 18 months

Inne miary wyników

Miara wyniku
Opis środka
Ramy czasowe
Number of eligible sensing vectors
Ramy czasowe: Baseline, 6, 12 and 18 months

Change in the number of sensing vectors that pass the subcutaneous ICD screening between baseline and each follow-up assessment.

Baseline, 6, 12 and 18 months
Eligibility according to electrode position
Ramy czasowe: Baseline, 6, 12 and 18 months

Proportion of participants eligible for the subcutaneous ICD in each screening electrode position.

Baseline, 6, 12 and 18 months
Comparison of subcutaneous ICD eligibility among study groups
Ramy czasowe: Baseline, 6, 12 and 18 months

Proportion of participants eligible for the subcutaneous ICD in the arrhythmogenic cardiomyopathy group compared with the Brugada syndrome reference group and the control group.

Baseline, 6, 12 and 18 months
Clinical factors associated with loss of subcutaneous ICD eligibility
Ramy czasowe: Baseline to 18 months

Clinical, electrocardiographic and imaging characteristics associated with loss of subcutaneous ICD eligibility during follow-up, reported as odds ratios with 95% confidence intervals.

Baseline to 18 months

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

8 lipca 2026

Zakończenie podstawowe (Szacowany)

1 lipca 2028

Ukończenie studiów (Szacowany)

1 lipca 2028

Daty rejestracji na studia

Pierwszy przesłany

24 września 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

24 września 2026

Pierwszy wysłany (Rzeczywisty)

30 września 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

5 października 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

1 października 2026

Ostatnia weryfikacja

1 października 2026

Więcej informacji

Terminy związane z tym badaniem

Słowa kluczowe

Inne numery identyfikacyjne badania

  • 98034926.8.0000.0068
  • 8.499.814 (Inny identyfikator: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo)

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj