Evaluation of Scanning and Diagnostic Performance of an Autonomous Dual-Arm Breast Ultrasound Robot

8 listopada 2026 zaktualizowane przez: Xiaoxv Yin, PhD, Huazhong University of Science and Technology

Evaluation of Scanning and Diagnostic Performance of an Autonomous Dual-Arm Breast Ultrasound Robot: A Prospective, Multicenter Study

This prospective, multicenter, intraindividual paired study aims to evaluate the autonomous scanning performance of a dual-arm robotic breast ultrasound system and the diagnostic performance of the images it acquires, in comparison with conventional handheld ultrasound. The study primarily focuses on the agreement between diagnostic assessments based on images obtained using the two examination methods, while also evaluating image quality, lesion detection, and measurement performance. The robotic ultrasound findings will be collected for research purposes only and will not be used to guide clinical management; all clinical decisions will be based on routine clinical assessment.

Przegląd badań

Szczegółowy opis

This is a prospective, multicenter, non-randomized, intraindividual paired clinical study. All eligible participants will undergo both autonomous breast ultrasound scanning using a dual-arm robotic ultrasound system and conventional handheld ultrasound examinations, with complete ultrasound images and videos retained for both examinations. Two senior ultrasound experts will independently review images from both modalities in a blinded manner, assessing lesion detection, localization, long and short diameters, sonographic features, and Breast Imaging Reporting and Data System (BI-RADS) categories. Disagreements will be resolved by a third expert.

The primary outcome is the agreement between expert BI-RADS assessments based on robotic ultrasound images and those based on conventional handheld ultrasound images. Secondary outcomes include imaging completeness and quality, lesion detection and localization, agreement in lesion size measurements, and patient-reported examination experiences. Additionally, the study will explore the patient-level diagnostic sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of both examination methods for breast cancer detection, as well as the impact of the robotic ultrasound AI-assisted diagnostic system on physicians' diagnostic performance.

Typ studiów

Obserwacyjny

Zapisy (Szacowany)

885

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Lokalizacje studiów

    • Hubei
      • Shiyan, Hubei, Chiny, 442000
        • Rekrutacyjny
        • Taihe Hospital of Shiyan City
        • Kontakt:
          • Xiaoxv Yin, Doctor
          • Numer telefonu: 86+13871187781
          • E-mail: yxx@hust.edu.cn
      • Wuhan, Hubei, Chiny, 430016
        • Jeszcze nie rekrutacja
        • Wuhan Children's Hospital
        • Kontakt:
      • Wuhan, Hubei, Chiny, 430030
        • Rekrutacyjny
        • Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology (Optical Valley Branch)
        • Kontakt:
      • Xiantao, Hubei, Chiny, 433000
        • Rekrutacyjny
        • Xiantao First People's Hospital
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat do 80 lat (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Kobieta

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

Participants will be recruited from the breast ultrasound outpatient clinics of three participating hospitals in Hubei Province, China. The study population will consist of adults aged 18-80 years with no history of breast cancer who voluntarily participate in breast ultrasound screening. All eligible participants will undergo conventional handheld breast ultrasound followed by autonomous dual-arm robotic breast ultrasound.

Opis

Inclusion Criteria:

  1. Aged 18-80 years.
  2. No history of breast cancer.
  3. Willing to voluntarily participate in breast screening.

Exclusion Criteria:

  1. History of breast resection surgery.
  2. Pregnant or breastfeeding women.
  3. Presence of prosthetic implants.
  4. Women with an allergy to ultrasound coupling gel.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Modele obserwacyjne: COHORT
  • Perspektywy czasowe: PROSPECTIVE

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
Breast Ultrasound Screening Cohort

Eligible participants will undergo conventional handheld breast ultrasound followed by autonomous dual-arm robotic breast ultrasound.

Participants will undergo autonomous dual-arm robotic breast ultrasound after conventional handheld ultrasound. The system will autonomously perform breast scanning and acquire ultrasound images for subsequent evaluation of imaging and diagnostic performance. The robotic ultrasound results will not be used to guide clinical management.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Ramy czasowe
Agreement Between Expert BI-RADS Classifications Based on Robotic and Handheld Breast Ultrasound Images
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Proportion of Examinations With Complete Breast Coverage Assessed by Expert Review of Ultrasound Recordings
Ramy czasowe: 6 weeks after completion of image collection for all participants

Breast scanning completeness will be assessed through expert review of the complete ultrasound recordings obtained using robotic and handheld ultrasound. Each examination will be classified as complete or incomplete (Yes/No) according to whether the predefined breast scanning regions are adequately covered. The outcome will be reported as the percentage of complete examinations for each modality.

6 weeks after completion of image collection for all participants
Overall Breast Ultrasound Image Quality Assessed Using a 5-Point Expert Rating Scale
Ramy czasowe: 6 weeks after completion of image collection for all participants

Overall image quality will be evaluated by experienced breast ultrasound experts using a 5-point ordinal rating scale (1 = poorest quality; 5 = best quality) based on the complete ultrasound recordings acquired using each modality.

6 weeks after completion of image collection for all participants
Lesion-Level Detection Sensitivity
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Mean Number of False-Positive Lesion Detections per Breast Ultrasound Examination
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Lesion Detection Precision
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Proportion of Breast Lesions With Accurate Localization Based on Expert Reference Assessment
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Agreement in Lesion Diameter Measurements
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Agreement Between Robotic and Handheld Ultrasound in Sonographic Features (Shape, Orientation, Margin, Echogenicity, and Posterior Acoustic Features) of Breast Lesions
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Patient-Reported Overall Satisfaction Score Using a 5-Point Questionnaire
Ramy czasowe: 6 weeks after completion of image collection for all participants

Responses will be coded on a 5-point ordinal scale: 1 = very dissatisfied, 2 = dissatisfied, 3 = neutral, 4 = satisfied, and 5 = very satisfied. Higher scores indicate greater satisfaction.

6 weeks after completion of image collection for all participants
Patient-Reported Pain Score Assessed Using a Study-Specific 5-Point Scale
Ramy czasowe: 6 weeks after completion of image collection for all participants

Each item will be coded on a 5-point ordinal scale, ranging from 1 (none) to 5 (very pronounced). Higher scores indicate greater perceived pressure, pain, or anxiety.

6 weeks after completion of image collection for all participants
Patient-Reported Anxiety Score Assessed Using a Study-Specific 5-Point Scale
Ramy czasowe: 6 weeks after completion of image collection for all participants

Each item will be coded on a 5-point ordinal scale, ranging from 1 (none) to 5 (very pronounced). Higher scores indicate greater perceived pressure, pain, or anxiety.

6 weeks after completion of image collection for all participants
Patient-Reported Probe Pressure Score Assessed Using a Study-Specific 5-Point Scale
Ramy czasowe: 6 weeks after completion of image collection for all participants

Each item will be coded on a 5-point ordinal scale, ranging from 1 (none) to 5 (very pronounced). Higher scores indicate greater perceived pressure, pain, or anxiety.

6 weeks after completion of image collection for all participants
Patient-Level Sensitivity for Breast Cancer Detection
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Patient-Level Specificity for Breast Cancer Detection
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Area Under the Receiver Operating Characteristic Curve (AUC) for Patient-Level Breast Cancer Detection
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Change in Patient-Level Sensitivity With Versus Without AI Assistance (Percentage Points)
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Change in Patient-Level Specificity With Versus Without AI Assistance (Percentage Points)
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants
Change in Area Under the Receiver Operating Characteristic Curve (AUC) With Versus Without AI Assistance
Ramy czasowe: 6 weeks after completion of image collection for all participants
6 weeks after completion of image collection for all participants

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 czerwca 2026

Zakończenie podstawowe (Szacowany)

31 grudnia 2027

Ukończenie studiów (Szacowany)

30 czerwca 2028

Daty rejestracji na studia

Pierwszy przesłany

21 października 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

28 października 2026

Pierwszy wysłany (Rzeczywisty)

4 listopada 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

12 listopada 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

8 listopada 2026

Ostatnia weryfikacja

1 listopada 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • HuazhongU2026

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .