Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Wearable Spine Assessment in Adults With and Without Low Back or Neck Pain (AxiSens-01)

16 juni 2026 uppdaterad av: Ashkan Vaziri

Wearable Spine Assessment in Adults With and Without Low Back or Neck Pain: A Single-Site Observational Feasibility and Validity Study

This is a single-site, prospective, observational, single-visit feasibility and validity study. Adult participants with and without low back or neck pain will be screened, consented, and enrolled to undergo a structured wearable-sensor-based spine assessment in a single on-site visit.

Approximately 20 participants will be enrolled at a single site:

  • Approximately 10 adults with self-reported chronic or subacute low back or neck pain (LBP/Neck Pain group)
  • Approximately 10 adults without current back or neck pain (Control group)

The AxiSens battery includes the Fingertip-to-Floor (FTF) test for lumbar flexion, the Chin-to-Chest (CTC) test for cervical flexion, a seated Trunk Stability Test on an unstable surface, the Cervical Flexor Endurance Test, the five-times sit-to-stand F5xSTS) test, and a brief functional task module covering overhead and forward reach.

To support intra-rater repeatability characterization, the AxiSens wearable assessment is performed twice within the same visit by a single trained operator, with sensor doffing and re-donning between the two assessments. A short rest interval is provided between the two assessments.

Following the on-site assessment, participants complete a brief end-of-session usability and tolerability questionnaire and the Technology Acceptance Model (TAM) questionnaire.

Studieöversikt

Status

Aktiv, inte rekryterande

Detaljerad beskrivning

Low back and neck pain are among the most common, costly, and disabling musculoskeletal conditions in the United States and worldwide. Low back pain is the leading cause of years lived with disability globally, and neck pain is consistently within the top ten. Both are leading drivers of healthcare expenditure, exceeding spending on diabetes, heart disease, and cancer in some recent analyses. Despite this magnitude, the clinical assessment of spine function remains heavily reliant on subjective self-report and clinician examination, with limited use of objective, quantitative, point-of-care measurement tools.

Wearable sensors, particularly inertial measurement units (IMUs), have matured into a credible technology base for objective musculoskeletal assessment. Multiple research groups have published validation studies establishing the accuracy of IMU-based segmental kinematics against optical motion capture, and feasibility studies demonstrating the utility of wearable kinematics in occupational and clinical settings. Most published wearable-spine assessment work to date has focused on lumbar kinematics in isolation, with cervical kinematic assessment less well-developed and integrated full-spine kinematic assessment relatively rare.

Recent peer-reviewed work demonstrated the feasibility of using wearable IMU technology to objectively assess cervical and upper-back posture in high-risk professional populations during prolonged work tasks. This work established that IMU-based monitoring of upper-body kinematics is feasible in real-world settings and that the methodology generates objective, reproducible data suitable for biofeedback and longitudinal monitoring. The current study extends this established methodology to a broader spine assessment configuration covering cervical, thoracic, lumbar, and pelvic segments, and integrated with validated patient-reported outcome instruments to enable a holistic biopsychosocial assessment of spine function.

The objective of this study is to evaluate the ability of a wearable, multi-modal spine assessment system - AxiSens - to discriminate between adults with low back or neck pain and healthy controls, and to characterize its intra-rater repeatability and workflow feasibility. There is no investigational therapeutic intervention. All participants undergo the same wearable-sensor-based spine assessment procedures in a single on-site visit. Approximately 20 participants will be enrolled, comprising approximately 10 participants in the LBP/Neck Pain group and approximately 10 participants in the Control group.

To support intra-rater repeatability characterization within this single-visit design, the AxiSens wearable assessment is performed twice within the visit by a single trained operator, with sensor doffing and re-donning between the two assessments and a short rest interval. The two within-visit assessments support estimation of the intra-rater repeatability of AxiSens-derived kinematic and composite outcomes.

Studietyp

Observationell

Inskrivning (Beräknad)

20

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Massachusetts
      • Newton, Massachusetts, Förenta staterna, 02458
        • BioSensics LLC

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Ja

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Healthy controls, individuals with neck pain, and individuals with low back pain.

Beskrivning

Inclusion Criteria:

  • Male or female, aged 18-65 years
  • Fluent in English (able to speak and read)
  • Ambulatory without the need for a walking aid
  • Able to independently perform all study activities safely, as determined by the investigator
  • Willing and able to provide informed consent and comply with all study procedures

For LBP/Neck Pain participants:

  • Self-reported low back or neck pain present for at least 4 weeks (subacute or chronic), with current Numeric Pain Rating Scale (NPRS) score of 3 or higher in the past 7 days
  • No history of spine surgery within the past 12 months

For Control participants:

• No current low back or neck pain (NPRS < 2 in the past 30 days) and no history of clinically significant spine condition or spine surgery

Exclusion Criteria:

Participants meeting any of the following criteria will be excluded from the study:

  • History of spine fracture, spinal deformity (e.g., scoliosis with Cobb angle > 25°), or spinal cord injury
  • Active radicular signs requiring imaging or specialist referral, as determined by the investigator
  • Neurological, vestibular, or musculoskeletal condition that would interfere with safe performance of the study tasks
  • Pregnant individuals
  • Skin condition or adhesive sensitivity precluding sensor application
  • Body mass index (BMI) < 18 kg/m² or > 40 kg/m²
  • Inability to provide informed consent or comply with study procedures

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Kohorter och interventioner

Grupp / Kohort
Control
Adults without low back or neck pain
Low back pain group
Adults with low back pain
Neck Pain
Adults with neck pain

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Group discrimination between control/low back pain/neck pain - Peak lumbar flexion range of motion
Tidsram: Baseline Visit
AxiSens system shall discriminate between groups based on peak lumbar flexion range of motion and lumbopelvic coordination ration during the Fingertip to Floor test.
Baseline Visit
Group discrimination between control/low back pain/neck pain - Peak cervical flexion range of motion
Tidsram: Baseline Visit
AxiSens system shall discriminate between groups based on peak cervical flexion range of motion and cervicothoracic coordination ration during the Chin to Chest test.
Baseline Visit
Group discrimination between control/low back pain/neck pain - Angular variability
Tidsram: Baseline Visit
AxiSens system shall discriminate between groups based on angular variability of the sagittal and frontal planes during the Trunk Stability test in eyes open and eyes closed conditions.
Baseline Visit
Group discrimination between control/low back pain/neck pain - Cervical flexor endurance time
Tidsram: Baseline Visit
AxiSens system shall discriminate between groups based on endurance time during the Cervical Flexor Endurance test.
Baseline Visit
Group discrimination between control/low back pain/neck pain - Five times sit-to-stand completion time
Tidsram: Baseline Visit
AxiSens system shall discriminate between groups based on completion time during the five times sit-to-stand test.
Baseline Visit

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Numeric Pain Rating Scale
Tidsram: Baseline Visit
The Numeric Pain Rating Scale (NPRS) is an 11-point, self-reported assessment tool where 0 means "no pain" and 10 represents the "worst pain imaginable." It is scored simply by recording the whole number indicated by the patient, usually evaluated for current, average, or worst pain levels.
Baseline Visit
Neck Disability Index
Tidsram: Baseline Visit
The Neck Disability Index (NDI) is a 10-question survey that measures how neck pain affects activities of daily life. Each section is scored from 0 to 5, where 5 is a worst outcome. The total is calculated as a percentage to determine the level of functional disability.
Baseline Visit
Oswestry Disability Index
Tidsram: Baseline Visit

The Oswestry Disability Index (ODI) is the gold standard patient-reported questionnaire used to quantify functional disability in individuals with low back pain. It evaluates 10 everyday activities, such as personal care, lifting, walking, and sleeping.

Each of the 10 sections is rated on a 6-point scale from 0 to 5, where 0 indicates no disability and 5 represents the most severe disability.

Baseline Visit
Pain, Enjoyment, General Activity (PEG-3)
Tidsram: Baseline Visit
The PEG-3 is used to assess chronic pain. Patients rate their pain, enjoyment of life, and general activity on a scale of 0 to 10 based on the past week. A higher score indicates a worst outcome.
Baseline Visit

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Sponsor

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

12 juni 2026

Primärt slutförande (Beräknad)

15 juli 2026

Avslutad studie (Beräknad)

30 juli 2026

Studieregistreringsdatum

Först inskickad

5 juni 2026

Först inskickad som uppfyllde QC-kriterierna

9 juni 2026

Första postat (Faktisk)

11 juni 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

17 juni 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

16 juni 2026

Senast verifierad

1 juni 2026

Mer information

Termer relaterade till denna studie

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera