- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07643207
Wearable Spine Assessment in Adults With and Without Low Back or Neck Pain (AxiSens-01)
Wearable Spine Assessment in Adults With and Without Low Back or Neck Pain: A Single-Site Observational Feasibility and Validity Study
This is a single-site, prospective, observational, single-visit feasibility and validity study. Adult participants with and without low back or neck pain will be screened, consented, and enrolled to undergo a structured wearable-sensor-based spine assessment in a single on-site visit.
Approximately 20 participants will be enrolled at a single site:
- Approximately 10 adults with self-reported chronic or subacute low back or neck pain (LBP/Neck Pain group)
- Approximately 10 adults without current back or neck pain (Control group)
The AxiSens battery includes the Fingertip-to-Floor (FTF) test for lumbar flexion, the Chin-to-Chest (CTC) test for cervical flexion, a seated Trunk Stability Test on an unstable surface, the Cervical Flexor Endurance Test, the five-times sit-to-stand F5xSTS) test, and a brief functional task module covering overhead and forward reach.
To support intra-rater repeatability characterization, the AxiSens wearable assessment is performed twice within the same visit by a single trained operator, with sensor doffing and re-donning between the two assessments. A short rest interval is provided between the two assessments.
Following the on-site assessment, participants complete a brief end-of-session usability and tolerability questionnaire and the Technology Acceptance Model (TAM) questionnaire.
연구 개요
상세 설명
Low back and neck pain are among the most common, costly, and disabling musculoskeletal conditions in the United States and worldwide. Low back pain is the leading cause of years lived with disability globally, and neck pain is consistently within the top ten. Both are leading drivers of healthcare expenditure, exceeding spending on diabetes, heart disease, and cancer in some recent analyses. Despite this magnitude, the clinical assessment of spine function remains heavily reliant on subjective self-report and clinician examination, with limited use of objective, quantitative, point-of-care measurement tools.
Wearable sensors, particularly inertial measurement units (IMUs), have matured into a credible technology base for objective musculoskeletal assessment. Multiple research groups have published validation studies establishing the accuracy of IMU-based segmental kinematics against optical motion capture, and feasibility studies demonstrating the utility of wearable kinematics in occupational and clinical settings. Most published wearable-spine assessment work to date has focused on lumbar kinematics in isolation, with cervical kinematic assessment less well-developed and integrated full-spine kinematic assessment relatively rare.
Recent peer-reviewed work demonstrated the feasibility of using wearable IMU technology to objectively assess cervical and upper-back posture in high-risk professional populations during prolonged work tasks. This work established that IMU-based monitoring of upper-body kinematics is feasible in real-world settings and that the methodology generates objective, reproducible data suitable for biofeedback and longitudinal monitoring. The current study extends this established methodology to a broader spine assessment configuration covering cervical, thoracic, lumbar, and pelvic segments, and integrated with validated patient-reported outcome instruments to enable a holistic biopsychosocial assessment of spine function.
The objective of this study is to evaluate the ability of a wearable, multi-modal spine assessment system - AxiSens - to discriminate between adults with low back or neck pain and healthy controls, and to characterize its intra-rater repeatability and workflow feasibility. There is no investigational therapeutic intervention. All participants undergo the same wearable-sensor-based spine assessment procedures in a single on-site visit. Approximately 20 participants will be enrolled, comprising approximately 10 participants in the LBP/Neck Pain group and approximately 10 participants in the Control group.
To support intra-rater repeatability characterization within this single-visit design, the AxiSens wearable assessment is performed twice within the visit by a single trained operator, with sensor doffing and re-donning between the two assessments and a short rest interval. The two within-visit assessments support estimation of the intra-rater repeatability of AxiSens-derived kinematic and composite outcomes.
연구 유형
등록 (추정된)
연락처 및 위치
연구 연락처
- 이름: Ashkan Vaziri, PhD
- 전화번호: 888-589-6213
- 이메일: ashkan.vaziri@biosensics.com
연구 장소
-
-
Massachusetts
-
Newton, Massachusetts, 미국, 02458
- 모병
- BioSensics LLC
-
연락하다:
- Ana Enriquez, BS
- 전화번호: 888-589-6213
- 이메일: ana.enriquez@biosensics.com
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Male or female, aged 18-65 years
- Fluent in English (able to speak and read)
- Ambulatory without the need for a walking aid
- Able to independently perform all study activities safely, as determined by the investigator
- Willing and able to provide informed consent and comply with all study procedures
For LBP/Neck Pain participants:
- Self-reported low back or neck pain present for at least 4 weeks (subacute or chronic), with current Numeric Pain Rating Scale (NPRS) score of 3 or higher in the past 7 days
- No history of spine surgery within the past 12 months
For Control participants:
• No current low back or neck pain (NPRS < 2 in the past 30 days) and no history of clinically significant spine condition or spine surgery
Exclusion Criteria:
Participants meeting any of the following criteria will be excluded from the study:
- History of spine fracture, spinal deformity (e.g., scoliosis with Cobb angle > 25°), or spinal cord injury
- Active radicular signs requiring imaging or specialist referral, as determined by the investigator
- Neurological, vestibular, or musculoskeletal condition that would interfere with safe performance of the study tasks
- Pregnant individuals
- Skin condition or adhesive sensitivity precluding sensor application
- Body mass index (BMI) < 18 kg/m² or > 40 kg/m²
- Inability to provide informed consent or comply with study procedures
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
|---|
|
Control
Adults without low back or neck pain
|
|
Low back pain group
Adults with low back pain
|
|
Neck Pain
Adults with neck pain
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Group discrimination between control/low back pain/neck pain - Peak lumbar flexion range of motion
기간: Baseline Visit
|
AxiSens system shall discriminate between groups based on peak lumbar flexion range of motion and lumbopelvic coordination ration during the Fingertip to Floor test.
|
Baseline Visit
|
|
Group discrimination between control/low back pain/neck pain - Peak cervical flexion range of motion
기간: Baseline Visit
|
AxiSens system shall discriminate between groups based on peak cervical flexion range of motion and cervicothoracic coordination ration during the Chin to Chest test.
|
Baseline Visit
|
|
Group discrimination between control/low back pain/neck pain - Angular variability
기간: Baseline Visit
|
AxiSens system shall discriminate between groups based on angular variability of the sagittal and frontal planes during the Trunk Stability test in eyes open and eyes closed conditions.
|
Baseline Visit
|
|
Group discrimination between control/low back pain/neck pain - Cervical flexor endurance time
기간: Baseline Visit
|
AxiSens system shall discriminate between groups based on endurance time during the Cervical Flexor Endurance test.
|
Baseline Visit
|
|
Group discrimination between control/low back pain/neck pain - Five times sit-to-stand completion time
기간: Baseline Visit
|
AxiSens system shall discriminate between groups based on completion time during the five times sit-to-stand test.
|
Baseline Visit
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Numeric Pain Rating Scale
기간: Baseline Visit
|
The Numeric Pain Rating Scale (NPRS) is an 11-point, self-reported assessment tool where 0 means "no pain" and 10 represents the "worst pain imaginable."
It is scored simply by recording the whole number indicated by the patient, usually evaluated for current, average, or worst pain levels.
|
Baseline Visit
|
|
Neck Disability Index
기간: Baseline Visit
|
The Neck Disability Index (NDI) is a 10-question survey that measures how neck pain affects activities of daily life.
Each section is scored from 0 to 5, where 5 is a worst outcome.
The total is calculated as a percentage to determine the level of functional disability.
|
Baseline Visit
|
|
Oswestry Disability Index
기간: Baseline Visit
|
The Oswestry Disability Index (ODI) is the gold standard patient-reported questionnaire used to quantify functional disability in individuals with low back pain. It evaluates 10 everyday activities, such as personal care, lifting, walking, and sleeping. Each of the 10 sections is rated on a 6-point scale from 0 to 5, where 0 indicates no disability and 5 represents the most severe disability. |
Baseline Visit
|
|
Pain, Enjoyment, General Activity (PEG-3)
기간: Baseline Visit
|
The PEG-3 is used to assess chronic pain.
Patients rate their pain, enjoyment of life, and general activity on a scale of 0 to 10 based on the past week.
A higher score indicates a worst outcome.
|
Baseline Visit
|
공동 작업자 및 조사자
스폰서
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .
하부 요통에 대한 임상 시험
-
FibroGenAstraZeneca; Astellas Pharma Inc종료됨빈혈증 | 기본 MDS(Very Low, Low 또는 Intermediate IPSS-R with미국, 호주, 벨기에, 독일, 이스라엘, 이탈리아, 대한민국, 러시아 연방, 스페인, 영국, 프랑스, 칠면조, 캐나다, 덴마크, 인도, 폴란드
-
Bingol UniversityAtaturk University아직 모집하지 않음수술 전 불안 | 두려움 | PAIN
-
Cancer Institute and Hospital, Chinese Academy...모병내장 위기로 인해 복잡한 HER2-LOW 절제 불가능한/전이성 유방암중국
-
Weill Medical College of Cornell UniversityNew York University; National Center for Complementary and Integrative Health (NCCIH)모병
-
Shanghai Henlius Biotech모병HER2-LOW 호르몬 수용체 양성 유방암중국
-
Université Victor Segalen Bordeaux 2Nanox International Laboratory (Belgique)완전한
-
Yeon Hee ParkHelsinn Healthcare SA초대로 등록T-DXD로 치료 한 HER2 양성 진행 유방암 환자 | T-DXD로 치료 한 HER2-LOW 진행된 유방암 환자대한민국
-
Eisai Inc.완전한LEC(Low Emetogenic Chemotherapy)를 받기 위해 확인된 악성 질환이 있는 환자 또는 LEC의 마지막 주기 동안 최소한 메스꺼움 및 구토를 경험한 환자미국
-
Istanbul University모병Masticatory Muscle Pain | 근시 통증 증후군 (MP)칠면조