Clinical Evaluation of Patient-Specific 3D-Printed Titanium Implants for Facial Reconstruction. (3DFACE)

11 juni 2026 uppdaterad av: Tishreen University

Evaluation of the Effectiveness of Patient-Specific 3D-Printed Titanium Facial Implants in the Reconstruction and Aesthetic Correction of Facial Defects: A Clinical Study

This clinical study aims to evaluate the effectiveness of patient-specific 3D-printed titanium facial implants in the reconstruction and aesthetic correction of facial defects. The study will include patients presenting with congenital, traumatic, or post-surgical facial deformities requiring reconstructive intervention.

Eligible participants will undergo preoperative clinical assessment and radiological imaging to design customized implants using computer-aided design (CAD) and 3D printing technology. The implants will be fabricated from medical-grade titanium and surgically placed according to standardized maxillofacial reconstructive protocols.

Postoperative follow-up will assess functional outcomes, implant stability, complication rates, and aesthetic improvement over a defined observation period. Outcome evaluation will include clinical examination and patient-reported satisfaction measures.

The objective of this study is to determine whether patient-specific 3D-printed titanium implants provide reliable functional restoration and improved aesthetic outcomes in facial reconstruction compared to conventional reconstructive techniques.

Studieöversikt

Detaljerad beskrivning

Background:

Facial bone defects and contour deformities may result from congenital anomalies, trauma, tumor resection, cystic lesions, or developmental deficiencies. Conventional reconstructive techniques often rely on standard implants or intraoperative modification of grafts, which may not provide optimal anatomical adaptation or aesthetic outcomes.

Recent advances in three-dimensional (3D) imaging, computer-aided design (CAD), and additive manufacturing technologies have enabled the production of patient-specific titanium implants tailored to the unique anatomy of individual patients. These implants may improve surgical precision, reduce operative time, enhance facial symmetry, and provide more predictable functional and aesthetic outcomes.

Objective:

This clinical study aims to evaluate the effectiveness, safety, and clinical performance of patient-specific 3D-printed titanium facial implants in the reconstruction and aesthetic correction of facial defects.

Methods:

Eligible adult patients presenting with facial bone defects, facial asymmetry, congenital deformities, post-traumatic defects, or aesthetic indications requiring customized facial augmentation will undergo preoperative imaging using computed tomography (CT). Patient-specific titanium implants will be designed using computer-aided design software and manufactured using 3D-printing technology.

Clinical evaluation will include assessment of implant fit accuracy, facial symmetry, aesthetic outcomes, postoperative complications, patient satisfaction, and overall treatment success. Follow-up assessments will be performed at regular intervals for up to 12 months after surgery.

Expected Outcomes:

The study is expected to demonstrate that patient-specific 3D-printed titanium implants provide accurate anatomical reconstruction, improved facial aesthetics, high patient satisfaction, and acceptable safety profiles when used for facial reconstruction and contour correction.

Studietyp

Interventionell

Inskrivning (Beräknad)

30

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Studieorter

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen

Tar emot friska volontärer

Nej

Beskrivning

Inclusion Criteria:

  • Age 18 years or older.
  • Presence of facial bone defects resulting from cystic or tumoral osteolytic lesions.
  • Acquired or congenital facial deformities associated with bony defects or facial asymmetry.
  • Patients requiring patient-specific 3D-printed titanium implants for maxillofacial reconstruction.
  • Aesthetic indications requiring custom facial implant design, including microgenia (chin retrusion).
  • Ability to provide written informed consent.

Exclusion Criteria:

  • Active pathological lesions at the time of enrollment.
  • Age below 18 years.
  • History of radiotherapy within 12 months prior to enrollment.
  • Chronic untreated vitamin D deficiency.
  • Uncontrolled diabetes mellitus.
  • Inability or unwillingness to comply with follow-up requirements.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Behandling
  • Tilldelning: N/A
  • Interventionsmodell: Enskild gruppuppgift
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: Patient-Specific 3D-Printed Titanium Implant Reconstruction Group

Participants in this study will undergo reconstruction of facial defects using patient-specific three-dimensional (3D)-printed titanium implants. Preoperative planning will be performed using clinical assessment and high-resolution radiographic imaging to design customized implants tailored to each patient's anatomical defect. The implants will be fabricated from medical-grade titanium using additive manufacturing technology.

Surgical reconstruction will be performed under standard maxillofacial surgical protocols. The customized titanium implants will be positioned and fixed to restore both functional integrity and facial aesthetics. Postoperative follow-up will include clinical evaluation, radiographic assessment, and monitoring for complications, implant stability, and aesthetic outcomes over the defined study period.

Patient-specific 3D-printed titanium implants will be used for reconstruction of facial bone defects and correction of facial deformities. Each implant will be individually designed based on high-resolution computed tomography (CT) imaging and three-dimensional virtual surgical planning (VSP) using computer-aided design (CAD) software to accurately match the patient's anatomical defect.

The implants will be manufactured from medical-grade titanium alloy (Ti6Al4V) using selective laser melting (SLM) additive manufacturing technology. Post-processing will include surface finishing and sterilization prior to surgical use.

Surgical placement will be performed under general anesthesia following standard maxillofacial surgical protocols. The customized implants will be fixed to the native bone using titanium fixation screws when required to restore facial contour, structural support, and symmetry.

Postoperative follow-up will include clinical and radiological assessment using CT imaging t

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Postoperative Complication Rate
Tidsram: From surgery up to 6 months postoperatively
Assessment of postoperative complications following reconstruction with patient-specific 3D-printed titanium implants. Complications include infection, implant exposure, implant failure, or the need for revision surgery. Each patient will be assigned a binary score: 0 = no postoperative complication and 1 = presence of one or more postoperative complications. The outcome will be evaluated and recorded by the treating surgeon during the follow-up period. Higher values indicate a greater complication rate.
From surgery up to 6 months postoperatively
Outcome Measure Title: Implant Geometric Accuracy Assessed by 3D Deviation Analysis
Tidsram: Immediately after laser-based 3D printing of the implant and before surgical implantation.
Assessment of the geometric accuracy of the patient-specific 3D-printed titanium implant by performing three-dimensional scanning of the manufactured implant and comparing it with the original digital design using 3D deviation analysis software. Accuracy will be quantified as the root mean square (RMS) deviation between the scanned implant and the planned digital model. Lower deviation values indicate higher manufacturing accuracy.
Immediately after laser-based 3D printing of the implant and before surgical implantation.
Aesthetic Improvement Score
Tidsram: 3 months after surgery
Assessment of facial symmetry following reconstruction using a standardized 5-point facial symmetry scale evaluated by an independent plastic surgeon. Scores range from 1 (severe asymmetry) to 5 (excellent symmetry). Higher scores indicate better aesthetic outcomes.
3 months after surgery

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Total Operative Time (Minutes)
Tidsram: During surgery
Assessment of the total duration of the surgical procedure, measured from skin incision to wound closure and recorded in minutes. Operative time will be compared with historical data from conventional reconstruction techniques. Lower values indicate greater surgical efficiency.
During surgery
Patient Satisfaction Score Using a 10-Point Visual Analog Scale (VAS)
Tidsram: 3 months after surgery
Assessment of patient satisfaction with the reconstructive outcome using a 10-point Visual Analog Scale (VAS). The scale ranges from 0 to 10, where 0 indicates complete dissatisfaction and 10 indicates complete satisfaction. Higher scores indicate greater patient satisfaction.
3 months after surgery

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Studiestol: Basim A Slim, Tishreen University

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

26 april 2026

Primärt slutförande (Beräknad)

1 november 2026

Avslutad studie (Beräknad)

1 november 2026

Studieregistreringsdatum

Först inskickad

5 juni 2026

Först inskickad som uppfyllde QC-kriterierna

11 juni 2026

Första postat (Faktisk)

17 juni 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

17 juni 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

11 juni 2026

Senast verifierad

1 juni 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera