Clinical Evaluation of Patient-Specific 3D-Printed Titanium Implants for Facial Reconstruction. (3DFACE)

11 de junho de 2026 atualizado por: Tishreen University

Evaluation of the Effectiveness of Patient-Specific 3D-Printed Titanium Facial Implants in the Reconstruction and Aesthetic Correction of Facial Defects: A Clinical Study

This clinical study aims to evaluate the effectiveness of patient-specific 3D-printed titanium facial implants in the reconstruction and aesthetic correction of facial defects. The study will include patients presenting with congenital, traumatic, or post-surgical facial deformities requiring reconstructive intervention.

Eligible participants will undergo preoperative clinical assessment and radiological imaging to design customized implants using computer-aided design (CAD) and 3D printing technology. The implants will be fabricated from medical-grade titanium and surgically placed according to standardized maxillofacial reconstructive protocols.

Postoperative follow-up will assess functional outcomes, implant stability, complication rates, and aesthetic improvement over a defined observation period. Outcome evaluation will include clinical examination and patient-reported satisfaction measures.

The objective of this study is to determine whether patient-specific 3D-printed titanium implants provide reliable functional restoration and improved aesthetic outcomes in facial reconstruction compared to conventional reconstructive techniques.

Visão geral do estudo

Descrição detalhada

Background:

Facial bone defects and contour deformities may result from congenital anomalies, trauma, tumor resection, cystic lesions, or developmental deficiencies. Conventional reconstructive techniques often rely on standard implants or intraoperative modification of grafts, which may not provide optimal anatomical adaptation or aesthetic outcomes.

Recent advances in three-dimensional (3D) imaging, computer-aided design (CAD), and additive manufacturing technologies have enabled the production of patient-specific titanium implants tailored to the unique anatomy of individual patients. These implants may improve surgical precision, reduce operative time, enhance facial symmetry, and provide more predictable functional and aesthetic outcomes.

Objective:

This clinical study aims to evaluate the effectiveness, safety, and clinical performance of patient-specific 3D-printed titanium facial implants in the reconstruction and aesthetic correction of facial defects.

Methods:

Eligible adult patients presenting with facial bone defects, facial asymmetry, congenital deformities, post-traumatic defects, or aesthetic indications requiring customized facial augmentation will undergo preoperative imaging using computed tomography (CT). Patient-specific titanium implants will be designed using computer-aided design software and manufactured using 3D-printing technology.

Clinical evaluation will include assessment of implant fit accuracy, facial symmetry, aesthetic outcomes, postoperative complications, patient satisfaction, and overall treatment success. Follow-up assessments will be performed at regular intervals for up to 12 months after surgery.

Expected Outcomes:

The study is expected to demonstrate that patient-specific 3D-printed titanium implants provide accurate anatomical reconstruction, improved facial aesthetics, high patient satisfaction, and acceptable safety profiles when used for facial reconstruction and contour correction.

Tipo de estudo

Intervencional

Inscrição (Estimado)

30

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto

Aceita Voluntários Saudáveis

Não

Descrição

Inclusion Criteria:

  • Age 18 years or older.
  • Presence of facial bone defects resulting from cystic or tumoral osteolytic lesions.
  • Acquired or congenital facial deformities associated with bony defects or facial asymmetry.
  • Patients requiring patient-specific 3D-printed titanium implants for maxillofacial reconstruction.
  • Aesthetic indications requiring custom facial implant design, including microgenia (chin retrusion).
  • Ability to provide written informed consent.

Exclusion Criteria:

  • Active pathological lesions at the time of enrollment.
  • Age below 18 years.
  • History of radiotherapy within 12 months prior to enrollment.
  • Chronic untreated vitamin D deficiency.
  • Uncontrolled diabetes mellitus.
  • Inability or unwillingness to comply with follow-up requirements.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Patient-Specific 3D-Printed Titanium Implant Reconstruction Group

Participants in this study will undergo reconstruction of facial defects using patient-specific three-dimensional (3D)-printed titanium implants. Preoperative planning will be performed using clinical assessment and high-resolution radiographic imaging to design customized implants tailored to each patient's anatomical defect. The implants will be fabricated from medical-grade titanium using additive manufacturing technology.

Surgical reconstruction will be performed under standard maxillofacial surgical protocols. The customized titanium implants will be positioned and fixed to restore both functional integrity and facial aesthetics. Postoperative follow-up will include clinical evaluation, radiographic assessment, and monitoring for complications, implant stability, and aesthetic outcomes over the defined study period.

Patient-specific 3D-printed titanium implants will be used for reconstruction of facial bone defects and correction of facial deformities. Each implant will be individually designed based on high-resolution computed tomography (CT) imaging and three-dimensional virtual surgical planning (VSP) using computer-aided design (CAD) software to accurately match the patient's anatomical defect.

The implants will be manufactured from medical-grade titanium alloy (Ti6Al4V) using selective laser melting (SLM) additive manufacturing technology. Post-processing will include surface finishing and sterilization prior to surgical use.

Surgical placement will be performed under general anesthesia following standard maxillofacial surgical protocols. The customized implants will be fixed to the native bone using titanium fixation screws when required to restore facial contour, structural support, and symmetry.

Postoperative follow-up will include clinical and radiological assessment using CT imaging t

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Postoperative Complication Rate
Prazo: From surgery up to 6 months postoperatively
Assessment of postoperative complications following reconstruction with patient-specific 3D-printed titanium implants. Complications include infection, implant exposure, implant failure, or the need for revision surgery. Each patient will be assigned a binary score: 0 = no postoperative complication and 1 = presence of one or more postoperative complications. The outcome will be evaluated and recorded by the treating surgeon during the follow-up period. Higher values indicate a greater complication rate.
From surgery up to 6 months postoperatively
Outcome Measure Title: Implant Geometric Accuracy Assessed by 3D Deviation Analysis
Prazo: Immediately after laser-based 3D printing of the implant and before surgical implantation.
Assessment of the geometric accuracy of the patient-specific 3D-printed titanium implant by performing three-dimensional scanning of the manufactured implant and comparing it with the original digital design using 3D deviation analysis software. Accuracy will be quantified as the root mean square (RMS) deviation between the scanned implant and the planned digital model. Lower deviation values indicate higher manufacturing accuracy.
Immediately after laser-based 3D printing of the implant and before surgical implantation.
Aesthetic Improvement Score
Prazo: 3 months after surgery
Assessment of facial symmetry following reconstruction using a standardized 5-point facial symmetry scale evaluated by an independent plastic surgeon. Scores range from 1 (severe asymmetry) to 5 (excellent symmetry). Higher scores indicate better aesthetic outcomes.
3 months after surgery

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Total Operative Time (Minutes)
Prazo: During surgery
Assessment of the total duration of the surgical procedure, measured from skin incision to wound closure and recorded in minutes. Operative time will be compared with historical data from conventional reconstruction techniques. Lower values indicate greater surgical efficiency.
During surgery
Patient Satisfaction Score Using a 10-Point Visual Analog Scale (VAS)
Prazo: 3 months after surgery
Assessment of patient satisfaction with the reconstructive outcome using a 10-point Visual Analog Scale (VAS). The scale ranges from 0 to 10, where 0 indicates complete dissatisfaction and 10 indicates complete satisfaction. Higher scores indicate greater patient satisfaction.
3 months after surgery

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Cadeira de estudo: Basim A Slim, Tishreen University

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

26 de abril de 2026

Conclusão Primária (Estimado)

1 de novembro de 2026

Conclusão do estudo (Estimado)

1 de novembro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

5 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

11 de junho de 2026

Primeira postagem (Real)

17 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

17 de junho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

11 de junho de 2026

Última verificação

1 de junho de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever