A Registry Evaluating the Real-World Clinical Use, Procedural Characteristics, Safety, and Effectiveness of the VARIPULSE™ PRO Pulsed Field Ablation Platform for the Treatment of Atrial Fibrillation

13 november 2026 uppdaterad av: Waterloo Regional Health Network

Real-World Outcomes and Procedural Practice Patterns of VARIPULSE™ PRO Ablation for Atrial Fibrillation

The purpose of this study is to learn more about how safe and how well a treatment called catheter ablation works to treat atrial fibrillation (AF) when the VARIPULSE system is used.

This study collects information from people receiving this treatment as part of their usual medical care. Researchers want to understand how the procedure is used in everyday practice.

The secondary purpose of this study is to create a registry to collect data to be used for future research.

Studieöversikt

Status

Har inte rekryterat ännu

Betingelser

Studietyp

Observationell

Inskrivning (Beräknad)

500

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Patients undergoing catheter ablation for atrial fibrillation using the VARIPULSE PRO platform.

Beskrivning

Inclusion Criteria:

  • Symptomatic paroxysmal atrial fibrillation (AF episode that terminates spontaneously within 7 days)
  • Indicated for catheter ablation in the opinion of the investigator
  • De Novo and redo AF ablation procedures
  • Age > 18 years
  • Will be treated with Biosense Webster Inc. Ablation Technologies
  • All AF ablations performed with BWI technology.
  • Able and willing to participate in baseline and follow-up evaluations.

Exclusion Criteria:

  • Age <18 years
  • Persistent atrial fibrillation
  • Non-AF ablation procedures without AF treatment
  • Inability to provide informed consent
  • Enrolled in an investigational drug or device clinical trial, or any trial that dictates the treatment plan
  • In the opinion of the investigator, any known contraindication to an ablation procedure

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Observationsmodeller: OTHER
  • Tidsperspektiv: OTHER

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Procedural Characteristics and Lesion Delivery Patterns of VARIPULSE™-Based Atrial Fibrillation Ablation Using the PRO Sequence
Tidsram: During the index ablation procedure.

To characterize real-world procedural practices associated with VARIPULSE™ pulsed field ablation using the PRO sequence in patients undergoing atrial fibrillation ablation. Measures will include total number of PFA applications, number of applications delivered per pulmonary vein, lesion distribution within the left atrium, completeness of pulmonary vein lesion sets, and use of adjunctive ablation strategies. Additional lesion sets, including posterior wall isolation, roof line, mitral isthmus, cavotricuspid isthmus, anterior wall and other mapped atrial tachycardia targets, will also be documented.

During the index ablation procedure.
Procedural Workflow and Efficiency Metrics
Tidsram: During the index ablation procedure.

To evaluate procedural workflow, duration and resource utilization during VARIPULSE™-based atrial fibrillation ablation. Measures will include total procedure duration, left atrial dwell time, fluoroscopy time, radiation dose, number of transseptal punctures, total ablation time, and use of adjunctive ablation technologies, including supplemental radiofrequency ablation. Additional procedural characteristics will include anesthesia type, ventilation strategy, intracardiac echocardiography utilization, electroanatomical mapping workflow and left atrial voltage map acquisition.

During the index ablation procedure.
Pulmonary Vein Lesion Delivery and Isolation Characteristics
Tidsram: During the index ablation procedure.

To characterize pulmonary vein lesion delivery and isolation efficiency during VARIPULSE™ PFA procedures using the PRO sequence. Measures will include total lesions delivered, number of lesions per pulmonary vein, completeness of concentric lesion rings, number of lesions required to achieve pulmonary vein isolation, and pulmonary vein isolation transpired time. Pulmonary vein isolation transpired time is defined as the interval between the first and final pulmonary vein ablation applications, excluding subsequent touch-up lesions performed following additional linear lesion sets.

During the index ablation procedure.

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

1 november 2026

Primärt slutförande (Beräknad)

1 november 2027

Avslutad studie (Beräknad)

1 februari 2028

Studieregistreringsdatum

Först inskickad

4 november 2026

Först inskickad som uppfyllde QC-kriterierna

13 november 2026

Första postat (Faktisk)

17 november 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

17 november 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

13 november 2026

Senast verifierad

1 november 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

OBESLUTSAM

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera