A Registry Evaluating the Real-World Clinical Use, Procedural Characteristics, Safety, and Effectiveness of the VARIPULSE™ PRO Pulsed Field Ablation Platform for the Treatment of Atrial Fibrillation
Real-World Outcomes and Procedural Practice Patterns of VARIPULSE™ PRO Ablation for Atrial Fibrillation
The purpose of this study is to learn more about how safe and how well a treatment called catheter ablation works to treat atrial fibrillation (AF) when the VARIPULSE system is used.
This study collects information from people receiving this treatment as part of their usual medical care. Researchers want to understand how the procedure is used in everyday practice.
The secondary purpose of this study is to create a registry to collect data to be used for future research.
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Tanulmány típusa
Beiratkozás (Becsült)
Kapcsolatok és helyek
Tanulmányi kapcsolat
- Név: Carla Girolametto
- Telefonszám: 5194974300
- E-mail: carla.girolametto@wrhn.ca
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Mintavételi módszer
Tanulmányi populáció
Patients undergoing catheter ablation for atrial fibrillation using the VARIPULSE PRO platform.
Leírás
Inclusion Criteria:
- Symptomatic paroxysmal atrial fibrillation (AF episode that terminates spontaneously within 7 days)
- Indicated for catheter ablation in the opinion of the investigator
- De Novo and redo AF ablation procedures
- Age > 18 years
- Will be treated with Biosense Webster Inc. Ablation Technologies
- All AF ablations performed with BWI technology.
- Able and willing to participate in baseline and follow-up evaluations.
Exclusion Criteria:
- Age <18 years
- Persistent atrial fibrillation
- Non-AF ablation procedures without AF treatment
- Inability to provide informed consent
- Enrolled in an investigational drug or device clinical trial, or any trial that dictates the treatment plan
- In the opinion of the investigator, any known contraindication to an ablation procedure
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Megfigyelési modellek: OTHER
- Időperspektívák: OTHER
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Procedural Characteristics and Lesion Delivery Patterns of VARIPULSE™-Based Atrial Fibrillation Ablation Using the PRO Sequence
Időkeret: During the index ablation procedure.
|
To characterize real-world procedural practices associated with VARIPULSE™ pulsed field ablation using the PRO sequence in patients undergoing atrial fibrillation ablation. Measures will include total number of PFA applications, number of applications delivered per pulmonary vein, lesion distribution within the left atrium, completeness of pulmonary vein lesion sets, and use of adjunctive ablation strategies. Additional lesion sets, including posterior wall isolation, roof line, mitral isthmus, cavotricuspid isthmus, anterior wall and other mapped atrial tachycardia targets, will also be documented. |
During the index ablation procedure.
|
|
Procedural Workflow and Efficiency Metrics
Időkeret: During the index ablation procedure.
|
To evaluate procedural workflow, duration and resource utilization during VARIPULSE™-based atrial fibrillation ablation. Measures will include total procedure duration, left atrial dwell time, fluoroscopy time, radiation dose, number of transseptal punctures, total ablation time, and use of adjunctive ablation technologies, including supplemental radiofrequency ablation. Additional procedural characteristics will include anesthesia type, ventilation strategy, intracardiac echocardiography utilization, electroanatomical mapping workflow and left atrial voltage map acquisition. |
During the index ablation procedure.
|
|
Pulmonary Vein Lesion Delivery and Isolation Characteristics
Időkeret: During the index ablation procedure.
|
To characterize pulmonary vein lesion delivery and isolation efficiency during VARIPULSE™ PFA procedures using the PRO sequence. Measures will include total lesions delivered, number of lesions per pulmonary vein, completeness of concentric lesion rings, number of lesions required to achieve pulmonary vein isolation, and pulmonary vein isolation transpired time. Pulmonary vein isolation transpired time is defined as the interval between the first and final pulmonary vein ablation applications, excluding subsequent touch-up lesions performed following additional linear lesion sets. |
During the index ablation procedure.
|
Együttműködők és nyomozók
Szponzor
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Becsült)
Elsődleges befejezés (Becsült)
A tanulmány befejezése (Becsült)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- VANTAGE-AF
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .