此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Optimal Shock Energy for Electrical Cardioversion of Atrial Fibrillation

2026年5月20日 更新者:Jan Naar、Motol and Homolka University Hospital

Optimal Initial Shock Energy for Elective Direct Current Biphasic Electrical Cardioversion of Atrial Fibrillation

Introduction For elective electrical cardioversion of atrial fibrillation, the recommended standard is the administration of a biphasic direct current shock. However, there is considerable variability among physicians regarding the choice of the initial shock energy, as current clinical guidelines do not specify it precisely. The guidelines of American cardiology societies recommend a shock intensity of at least 200 J, while the European Society of Cardiology guidelines do not comment on shock energy at all.

Evidence from a previous randomized clinical trial has shown that using a higher initial shock energy (360 J) is more effective, safe, and reduces the cumulative delivered energy, since lower initial shock energy more frequently requires repeated shocks. The safety of the maximal-energy protocol was demonstrated in this study, among other by the absence of myocardial injury as assessed by cardiac troponin I levels measured 4 hours after electrical cardioversion. However, in this study, the maximal initial shock energy protocol was compared with a low-energy escalating protocol (125-150-200 J), which is no longer supported by current clinical guidelines.

Objective The primary objective of the study is to compare the efficacy (short-term maintenance of sinus rhythm and the need for repeated shocks) of two regimens commonly used in clinical practice: 200-360-360 J and 360-360-360 J.

Secondary objectives are to identify factors that would justify the use of either lower or higher initial shock energy. Another secondary objective is to confirm the safety of the maximal initial shock energy protocol by assessing the biomarker of acute stress (copeptin) in a subpopulation of patients (n = 60).

Methods The main inclusion criterion for the study is the presence of atrial fibrillation or atypical atrial flutter and a clinical indication for electrical cardioversion raised an independent cardiologist. The main exclusion criterion is the presence of typical atrial flutter or focal atrial tachycardia, for which lower shock energy is recommended.

This is a prospective, randomized, single-blind (patient) study in which patients will be randomly assigned in a 1:1:1 ratio either to (i) 200-360-360 J protocol, (ii) 360-360-360 J protocol, or (iii) individualized selection of one of the above protocols based on additional parameters. I one of parameters next parameters is met, the 360-360-360 J protocol will be applied, if not, the 200-360-360 J protocol will be applied: Left atrial size > 55 mm, duration of the arrhythmia > 12 months, BMI > 30 kg/m2, chest circumference > 120 cm.

Since chest dimensions and the amount of subcutaneous fat may influence resistance to electrical current and thereby reduce the delivered electrical energy, chest dimensions and configuration will be evaluated prior to electrical cardioversion in addition to height and weight. The procedure itself (electrical cardioversion) will then be performed according to the standard institutional clinical practice.

研究概览

研究类型

介入性

注册 (估计的)

400

阶段

  • 不适用

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  • Atrial fibrillation
  • Atypical atrial flutter
  • Indication for elective electrical cardiac version made by independent physician

Exclusion Criteria:

  • Typical atrial flutter
  • Focal atrial tachycardia

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:200J protocol
Protocol of 200-360-360J will be applied
Direct current biphasic electrical cardioversion using Lifepak 20e (Medtronic) external defibrilator will be applied in antero-lateral vector.
6 mL blood samples will be taken from periferal vein before electrical cardiac version and 45 minutes after electrical cardiac version to assess biomarkers of stress and myocardial injury in 60 subjects.
实验性的:360J protocol
Protocol of 360-360-360J will be applied
Direct current biphasic electrical cardioversion using Lifepak 20e (Medtronic) external defibrilator will be applied in antero-lateral vector.
6 mL blood samples will be taken from periferal vein before electrical cardiac version and 45 minutes after electrical cardiac version to assess biomarkers of stress and myocardial injury in 60 subjects.
实验性的:Individual protocol
Protocol 200-360-360J or 360-360-360J will be selected according to other criteria
Direct current biphasic electrical cardioversion using Lifepak 20e (Medtronic) external defibrilator will be applied in antero-lateral vector.
6 mL blood samples will be taken from periferal vein before electrical cardiac version and 45 minutes after electrical cardiac version to assess biomarkers of stress and myocardial injury in 60 subjects.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Presence of sinus rhythm in 1, 5 and 120 minutes after electrical shock.
大体时间:2 hours
Presence of sinus rhythm will be assessed by experienced cardiologist using 3-lead ECG monitor (IntelliVue MP, Philips). If it cannot be concluded about the presence of sinus rhythm from 3-lead ECG monitor, standard 12-lead ECG will be performed using SE-1200 Express machine (EDAN).
2 hours

次要结果测量

结果测量
措施说明
大体时间
Cummulative shock energy
大体时间:5 minutes
Mean shock energy per intervention will be calculated in each arm as a sum of energies of all shocks delivered during one procedure divided by number of procedures.
5 minutes
Myocardial stress and injury
大体时间:45 minutes
Levels of copeptin and cardiac troponin I or T will be assessed 45 minutes after electrical shock delivery.
45 minutes

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年5月18日

初级完成 (估计的)

2028年12月1日

研究完成 (估计的)

2029年6月1日

研究注册日期

首次提交

2026年5月13日

首先提交符合 QC 标准的

2026年5月20日

首次发布 (实际的)

2026年5月28日

研究记录更新

最后更新发布 (实际的)

2026年5月28日

上次提交的符合 QC 标准的更新

2026年5月20日

最后验证

2026年5月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.