- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07610980
Optimal Shock Energy for Electrical Cardioversion of Atrial Fibrillation
Optimal Initial Shock Energy for Elective Direct Current Biphasic Electrical Cardioversion of Atrial Fibrillation
Introduction For elective electrical cardioversion of atrial fibrillation, the recommended standard is the administration of a biphasic direct current shock. However, there is considerable variability among physicians regarding the choice of the initial shock energy, as current clinical guidelines do not specify it precisely. The guidelines of American cardiology societies recommend a shock intensity of at least 200 J, while the European Society of Cardiology guidelines do not comment on shock energy at all.
Evidence from a previous randomized clinical trial has shown that using a higher initial shock energy (360 J) is more effective, safe, and reduces the cumulative delivered energy, since lower initial shock energy more frequently requires repeated shocks. The safety of the maximal-energy protocol was demonstrated in this study, among other by the absence of myocardial injury as assessed by cardiac troponin I levels measured 4 hours after electrical cardioversion. However, in this study, the maximal initial shock energy protocol was compared with a low-energy escalating protocol (125-150-200 J), which is no longer supported by current clinical guidelines.
Objective The primary objective of the study is to compare the efficacy (short-term maintenance of sinus rhythm and the need for repeated shocks) of two regimens commonly used in clinical practice: 200-360-360 J and 360-360-360 J.
Secondary objectives are to identify factors that would justify the use of either lower or higher initial shock energy. Another secondary objective is to confirm the safety of the maximal initial shock energy protocol by assessing the biomarker of acute stress (copeptin) in a subpopulation of patients (n = 60).
Methods The main inclusion criterion for the study is the presence of atrial fibrillation or atypical atrial flutter and a clinical indication for electrical cardioversion raised an independent cardiologist. The main exclusion criterion is the presence of typical atrial flutter or focal atrial tachycardia, for which lower shock energy is recommended.
This is a prospective, randomized, single-blind (patient) study in which patients will be randomly assigned in a 1:1:1 ratio either to (i) 200-360-360 J protocol, (ii) 360-360-360 J protocol, or (iii) individualized selection of one of the above protocols based on additional parameters. I one of parameters next parameters is met, the 360-360-360 J protocol will be applied, if not, the 200-360-360 J protocol will be applied: Left atrial size > 55 mm, duration of the arrhythmia > 12 months, BMI > 30 kg/m2, chest circumference > 120 cm.
Since chest dimensions and the amount of subcutaneous fat may influence resistance to electrical current and thereby reduce the delivered electrical energy, chest dimensions and configuration will be evaluated prior to electrical cardioversion in addition to height and weight. The procedure itself (electrical cardioversion) will then be performed according to the standard institutional clinical practice.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Atrial fibrillation
- Atypical atrial flutter
- Indication for elective electrical cardiac version made by independent physician
Exclusion Criteria:
- Typical atrial flutter
- Focal atrial tachycardia
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Separare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: 200J protocol
Protocol of 200-360-360J will be applied
|
Direct current biphasic electrical cardioversion using Lifepak 20e (Medtronic) external defibrilator will be applied in antero-lateral vector.
6 mL blood samples will be taken from periferal vein before electrical cardiac version and 45 minutes after electrical cardiac version to assess biomarkers of stress and myocardial injury in 60 subjects.
|
|
Sperimentale: 360J protocol
Protocol of 360-360-360J will be applied
|
Direct current biphasic electrical cardioversion using Lifepak 20e (Medtronic) external defibrilator will be applied in antero-lateral vector.
6 mL blood samples will be taken from periferal vein before electrical cardiac version and 45 minutes after electrical cardiac version to assess biomarkers of stress and myocardial injury in 60 subjects.
|
|
Sperimentale: Individual protocol
Protocol 200-360-360J or 360-360-360J will be selected according to other criteria
|
Direct current biphasic electrical cardioversion using Lifepak 20e (Medtronic) external defibrilator will be applied in antero-lateral vector.
6 mL blood samples will be taken from periferal vein before electrical cardiac version and 45 minutes after electrical cardiac version to assess biomarkers of stress and myocardial injury in 60 subjects.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Presence of sinus rhythm in 1, 5 and 120 minutes after electrical shock.
Lasso di tempo: 2 hours
|
Presence of sinus rhythm will be assessed by experienced cardiologist using 3-lead ECG monitor (IntelliVue MP, Philips).
If it cannot be concluded about the presence of sinus rhythm from 3-lead ECG monitor, standard 12-lead ECG will be performed using SE-1200 Express machine (EDAN).
|
2 hours
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Cummulative shock energy
Lasso di tempo: 5 minutes
|
Mean shock energy per intervention will be calculated in each arm as a sum of energies of all shocks delivered during one procedure divided by number of procedures.
|
5 minutes
|
|
Myocardial stress and injury
Lasso di tempo: 45 minutes
|
Levels of copeptin and cardiac troponin I or T will be assessed 45 minutes after electrical shock delivery.
|
45 minutes
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Malattia cardiovascolare
- Processi patologici
- Malattie cardiache
- Aritmie, cardiache
- Condizioni patologiche, segni e sintomi
- Fibrillazione atriale
- Tecniche investigative
- Gestione dei campioni
- Tecniche di laboratorio clinico
- Tecniche e procedure diagnostiche
- Diagnosi
- Forature
- Procedure chirurgiche, operative
- Collezione di campioni di sangue
Altri numeri di identificazione dello studio
- MotolHomolkaUH
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Fibrillazione atriale (FA)
-
Assiut UniversitySconosciutoAF non valvolare, AFEgitto
-
Sun Yat-Sen Memorial Hospital of Sun Yat-Sen UniversityThe First Affiliated Hospital of Nanchang University; Xiangya Hospital of Central... e altri collaboratoriIscrizione su invitoPazienti di ablazione AF con moderato+ FMR e AF persistenteCina
-
Oregon Health and Science UniversityRitirato
-
TriVirum, Inc.CompletatoFibrillazione atriale | Af | ECGStati Uniti
-
TriVirum, Inc.Completato
-
University Hospital DubravaAttivo, non reclutanteAblazione della fibrillazione atriale | AFCroazia
-
Pulse Biosciences, Inc.AvaniaReclutamentoFibrillazione atriale | Ablazione | Procedura del labirinto | AFStati Uniti
-
Vivek ReddyCompletatoAF persistente di lunga durataStati Uniti
-
TriVirum, Inc.CompletatoFibrillazione atriale | Aritmie, cardiache | Fibrillazione atriale parossistica | Af | Battito cardiaco irregolare | Aritmia atriale | Aritmie parossisticheStati Uniti
-
The Cleveland ClinicUniversity of WashingtonReclutamentoCPAP | Sindrome da apnea notturna, ostruttiva | AfStati Uniti
Prove cliniche su Direct current biphasic electrical cardioversion
-
The University of Texas Health Science Center,...Completato
-
Minneapolis Veterans Affairs Medical CenterCenter for Veterans Research and EducationCompletatoObesità | Impulsività | Eccesso di cibo compulsivoStati Uniti
-
Angiodynamics, Inc.CompletatoCarcinoma, epatocellulareFrancia, Germania, Italia, Spagna