Predicting Peritoneal Kt/Vurea Based on Single-Exchange Dialysate Effluent
Development and Validation of a Prediction Model for Peritoneal Kt/Vurea Using Single-Exchange Dialysate Effluent in Patients Undergoing Peritoneal Dialysis
Background:
Peritoneal dialysis (PD) adequacy is routinely evaluated using the urea clearance index (Kt/Vurea), a key indicator of small-solute clearance and treatment adequacy. The standard method for calculating peritoneal Kt/Vurea requires complete collection of 24-hour dialysate effluent, which is labor-intensive, time-consuming, and prone to errors arising from incomplete collection, inadequate mixing, and inaccurate sampling. Although proportional sampling from each exchange has been shown to yield results comparable to those obtained from complete 24-hour effluent collection, this approach still requires collection of all exchanges throughout the day. Previous studies have suggested that Kt/Vurea estimated from a single dialysate exchange may correlate with the standard measurement; however, these investigations were limited by small sample sizes and did not establish predictive equations. Therefore, a practical and accurate alternative for assessing peritoneal Kt/Vurea is still lacking.
Objective:
To develop and validate a prediction model for peritoneal Kt/Vurea based on single-exchange dialysate effluent in patients undergoing PD.
Methods:
This multicenter cross-sectional study will be conducted between 2026 and 2027 across four PD centers in China. Consecutive prevalent patients receiving manual PD will be screened for eligibility. Patients aged ≥14 years who have been receiving PD for at least one month will be included. Exclusion criteria comprise peritonitis or other acute complications within the preceding month, spontaneous ascites, inability to complete full dialysate collection during the study day, and refusal to provide informed consent. Demographic characteristics, primary kidney disease, comorbidities, and PD prescription parameters will be collected. On a designated study day, effluent from each dialysis exchange, 24-hour urine samples, and fasting blood samples will be obtained. The correlations between peritoneal Kt/Vurea calculated from individual exchanges and the reference peritoneal Kt/Vurea derived from complete 24-hour dialysate collection will be evaluated. Multivariable prediction models incorporating single-exchange effluent measurements and relevant clinical parameters will subsequently be developed and validated. Model performance will be assessed using measures of discrimination, calibration, and agreement with reference Kt/Vurea values.
Conclusions:
This study aims to establish and validate a simplified method for estimating peritoneal Kt/Vurea using single-exchange dialysate effluent. If validated, the proposed model may substantially reduce the burden associated with 24-hour dialysate collection while maintaining adequate accuracy for routine assessment of PD adequacy.
研究概览
地位
条件
详细说明
研究类型
注册 (估计的)
参与标准
资格标准
适合学习的年龄
- 孩子
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
Patients aged ≥14 years who have been receiving PD for at least one month.
Exclusion Criteria:
(1) peritonitis or other acute complications (e.g., severe infection or acute heart failure) within 1 month prior to enrollment; (2) spontaneous ascites; (3) inability to complete full collection of all dialysate effluent during the study dialysis day; (4) refusal or inability to provide written informed consent.
学习计划
研究是如何设计的?
设计细节
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
Accuracy of prediction of peritoneal Kt/Vurea using single-exchange dialysate effluent
大体时间:Baseline (single assessment)
|
Baseline (single assessment)
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- Peritoneal Kt/Vurea
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.