Improving Assessment (and Ultimately Outcomes) of Permanent Prostate Implant Therapy

March 14, 2016 updated by: AHS Cancer Control Alberta
Permanent prostate implants are a type of radiation therapy in which a high dose of radiation is delivered to cancerous tissue by many small radioactive "seeds". Studies of early-stage prostate cancer patients treated in this way and followed for 10 - 12 years indicate a cure rate of about 80%. This result is similar to surgery and other forms of radiotherapy, but comes with fewer side effects and greater convenience for the patient. Further studies show that the radiation dose delivered is the most important factor in achieving a cure. At present this dose is estimated by a computer, using a computed tomography (CT) scan of the patient and a simple calculation method. The dose estimate is not as accurate as it could be, however, because the precise extent of the prostate is hard to determine from the CT scan, and the calculation method does not make use of information about patient body tissues. The researchers propose to eliminate these inaccuracies by using magnetic resonance imaging (MRI) to identify the prostate gland and by developing an improved dose calculation algorithm that includes information about patient tissues. This new approach will allow physicians to assess implant quality with greater certainty, improve their implant technique, and ultimately increase the cure rate to as much as 95%.

Study Overview

Status

Completed

Conditions

Detailed Description

This study addresses three major sources of post-implant dosimetry inaccuracy for permanent prostate implants: post-operative edema, prostate contour delineation, and dose calculation method. It is hypothesized that a pragmatic edema model can minimize the first uncertainty, co-registered CT + MR images the second, and an improved dose calculation algorithm the third.

Detailed objectives are to:

  • measure and model the effects of edema on dosimetry;
  • evaluate CT + MR image registration methods;
  • compare dosimetry for CT alone vs. CT + MRI using the contemporary TG-43 dose calculation method;
  • set up a Monte Carlo code that makes full use of the information in CT + MR images to perform implant dose calculations;
  • compare prostate dosimetry for the Monte Carlo vs. the simpler TG-43 method;
  • develop an analytical post-implant dose calculation algorithm for routine clinical use (Monte Carlo is too slow on a single-CPU brachytherapy planning computer); and finally
  • assess the performance of the new algorithm.

Of the estimated 250,000 new cases of prostate cancer in North America in 2004, most are early stage disease as a consequence of PSA testing. Permanent prostate implant therapy is a major option for this group, as long-term clinical studies indicate a cure rate equal to surgery and external beam radiotherapy, but with fewer complications. By dealing with dosimetric inaccuracies, a proven treatment can reach its full potential.

Study Type

Interventional

Enrollment (Actual)

40

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Alberta
      • Edmonton, Alberta, Canada, T6G 1Z2
        • Cross Cancer Institute

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • ADULT
  • OLDER_ADULT
  • CHILD

Accepts Healthy Volunteers

No

Genders Eligible for Study

Male

Description

Inclusion Criteria:

  • Candidate for permanent prostate implant

Exclusion Criteria:

  • Not ambulatory

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: NA
  • Interventional Model: SINGLE_GROUP
  • Masking: NONE

What is the study measuring?

Primary Outcome Measures

Outcome Measure
implant dose coverage at 4 weeks, comparing CT and MRI versus CT alone

Secondary Outcome Measures

Outcome Measure
implant edema at time of implant and at 2 and 4 weeks

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Collaborators

Investigators

  • Principal Investigator: Ron Sloboda, PhD, AHS Cancer Control Alberta

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

April 1, 2005

Primary Completion (ACTUAL)

April 1, 2013

Study Completion (ACTUAL)

April 1, 2013

Study Registration Dates

First Submitted

August 5, 2005

First Submitted That Met QC Criteria

August 5, 2005

First Posted (ESTIMATE)

August 9, 2005

Study Record Updates

Last Update Posted (ESTIMATE)

March 16, 2016

Last Update Submitted That Met QC Criteria

March 14, 2016

Last Verified

March 1, 2016

More Information

Terms related to this study

Other Study ID Numbers

  • SP-14-0044 / 21694
  • RIP Project 21694

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.