Stenting and Angioplasty With Protection in Patients at High Risk for Endarterectomy (SAPPHIRE)

April 17, 2008 updated by: Cordis Corporation

Stenting and Angioplasty With Protection in Patients at High Risk for Endarterectomy

The primary objective of this study is to compare the safety and effectiveness of the Cordis Nitinol Carotid Stent and Delivery Systems (5.5 F and 7 F) with the ANGIOGUARD XP distal protective device to CEA in the treatment of carotid artery disease in patients at increased risk for surgery.

Study Overview

Study Type

Interventional

Enrollment

1300

Phase

  • Phase 3

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

14 years to 76 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. The patient must be > 18 years of age.
  2. The patient has a 50% stenosis (as determined by ultrasound or angiogram) of the common or internal carotid artery and is clinically symptomatic; i.e., within the previous 180 days has experienced symptoms in the ipsilateral carotid artery distribution, defined as:

    • one or more TIAs, characterized by distinct focal neurologic dysfunction or monocular blindness with clearing of signs and symptoms within 24 hours, or
    • one or more completed strokes (as defined by this protocol) with persistence of symptoms or signs for more than 24 hours (the most recent event is used as the qualifying event), except as excluded below, with stenosis >50%, (as determined by ultrasound or angiogram) of the common or internal carotid artery, OR The patient must have a >80% diameter stenosis (as determined by ultrasound or angiogram) of the internal or common carotid artery without neurological symptoms.
  3. To be entered into the study, the patient must have one or more of the following conditions:

    • congestive heart failure (class III/IV) and/or known severe left ventricular dysfunction LVEF < 30%
    • open heart surgery within six weeks
    • recent MI (>24 hours and <4 weeks)
    • unstable angina (CCS class III/IV)
    • synchronous severe cardiac and carotid disease requiring open heart surgery and carotid revascularization
    • Age greater than 80 years as a single risk factor.

Exclusion Criteria:

  1. The patient is experiencing an acute ischemic neurologic stroke or has experienced a stroke within the past 48 hours.
  2. The patient has an intracranial mass lesion (i.e., abscess, tumor, or infection).
  3. The reference segment diameter (distal common carotid and internal carotid artery segment cephalic to the lesion) is less than 4mm or greater than 9mm by quantitative analysis. See Instructions For Use, for proper stent sizing. The exception to this would be with a lesion having >95% stenosis where the true diameter of the distal vessel can not be determined such as the case with a string sign or distal vessel collapse. In this case the judgment of the interventionalist will prevail with the intention not to oversize the stent to the distal vessel by more than 2mm.
  4. The patient has known peripheral vascular, supra-aortic or internal carotid artery tortuosity which preclude the use of catheter-based techniques if so randomized.
  5. The patient has any intracranial aneurysm (> 9 mm).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
composite of major adverse clinical events including death, any stroke, and/or myocardial infarction at 30-days post-procedure
Time Frame: 30-days post-procedure
30-days post-procedure
The same 30-day composite of major adverse clinical events plus death and/or ipsilateral stroke between 31-days and 12-months post-procedure.
Time Frame: Between day 31 and 12-months post-procedure.
Between day 31 and 12-months post-procedure.

Secondary Outcome Measures

Outcome Measure
Time Frame
successful stent deployment at the target lesion in a variety of carotid morphologies
successful filter deployment and retrieval
<30% residual stenosis determined by angiography immediately post-stent placement and post-dilatation
endovascular access site complications, such as the need for surgical repair or blood transfusion
surgical site complications, such as wound infection or hematoma, that prolong hospital stay, require incision and drainage, or need blood transfusion
patency (< 50% restenosis) of the Cordis Nitinol Stent as determined by carotid ultrasound imaging within 48 hours, at six months, and one, two and three years post-procedure
independent neurologic assessments at 24 + 12 hours, thirty days, six months, and one, two and three years post-procedure (in addition to stroke scales, the development of any cranial nerve deficits will be recorded) - persistent neurologic deficits
thirty (30)-day and six (6)-month evaluation for disabling stroke
Time Frame: Day 30 and 6 months
Day 30 and 6 months
six (6)-month, one (1)-year, two (2)-year and three (3)-year composite of major adverse clinical events including death and ipsilateral stroke
Time Frame: 6 month and 1, 2, 3yr
6 month and 1, 2, 3yr
safety assessment of the ANGIOGUARD XP Emboli Capture Guidewire Device
presence of trapped material as determined by the interventionalist's visual inspection of the ANGIOGUARD XP filter basket following recapture at the completion of the procedure
laboratory analysis of trapped material contained in the ANGIOGUARD XP filter basket

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

August 1, 2000

Study Completion (Actual)

August 1, 2005

Study Registration Dates

First Submitted

October 3, 2005

First Submitted That Met QC Criteria

October 3, 2005

First Posted (Estimate)

October 4, 2005

Study Record Updates

Last Update Posted (Estimate)

April 24, 2008

Last Update Submitted That Met QC Criteria

April 17, 2008

Last Verified

July 1, 2007

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe