- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT00231270
Stenting and Angioplasty With Protection in Patients at High Risk for Endarterectomy (SAPPHIRE)
April 17, 2008 updated by: Cordis Corporation
Stenting and Angioplasty With Protection in Patients at High Risk for Endarterectomy
The primary objective of this study is to compare the safety and effectiveness of the Cordis Nitinol Carotid Stent and Delivery Systems (5.5 F and 7 F) with the ANGIOGUARD XP distal protective device to CEA in the treatment of carotid artery disease in patients at increased risk for surgery.
Study Overview
Status
Completed
Conditions
Study Type
Interventional
Enrollment
1300
Phase
- Phase 3
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
14 years to 76 years (Adult, Older Adult)
Accepts Healthy Volunteers
No
Genders Eligible for Study
All
Description
Inclusion Criteria:
- The patient must be > 18 years of age.
The patient has a 50% stenosis (as determined by ultrasound or angiogram) of the common or internal carotid artery and is clinically symptomatic; i.e., within the previous 180 days has experienced symptoms in the ipsilateral carotid artery distribution, defined as:
- one or more TIAs, characterized by distinct focal neurologic dysfunction or monocular blindness with clearing of signs and symptoms within 24 hours, or
- one or more completed strokes (as defined by this protocol) with persistence of symptoms or signs for more than 24 hours (the most recent event is used as the qualifying event), except as excluded below, with stenosis >50%, (as determined by ultrasound or angiogram) of the common or internal carotid artery, OR The patient must have a >80% diameter stenosis (as determined by ultrasound or angiogram) of the internal or common carotid artery without neurological symptoms.
To be entered into the study, the patient must have one or more of the following conditions:
- congestive heart failure (class III/IV) and/or known severe left ventricular dysfunction LVEF < 30%
- open heart surgery within six weeks
- recent MI (>24 hours and <4 weeks)
- unstable angina (CCS class III/IV)
- synchronous severe cardiac and carotid disease requiring open heart surgery and carotid revascularization
- Age greater than 80 years as a single risk factor.
Exclusion Criteria:
- The patient is experiencing an acute ischemic neurologic stroke or has experienced a stroke within the past 48 hours.
- The patient has an intracranial mass lesion (i.e., abscess, tumor, or infection).
- The reference segment diameter (distal common carotid and internal carotid artery segment cephalic to the lesion) is less than 4mm or greater than 9mm by quantitative analysis. See Instructions For Use, for proper stent sizing. The exception to this would be with a lesion having >95% stenosis where the true diameter of the distal vessel can not be determined such as the case with a string sign or distal vessel collapse. In this case the judgment of the interventionalist will prevail with the intention not to oversize the stent to the distal vessel by more than 2mm.
- The patient has known peripheral vascular, supra-aortic or internal carotid artery tortuosity which preclude the use of catheter-based techniques if so randomized.
- The patient has any intracranial aneurysm (> 9 mm).
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
composite of major adverse clinical events including death, any stroke, and/or myocardial infarction at 30-days post-procedure
Time Frame: 30-days post-procedure
|
30-days post-procedure
|
|
The same 30-day composite of major adverse clinical events plus death and/or ipsilateral stroke between 31-days and 12-months post-procedure.
Time Frame: Between day 31 and 12-months post-procedure.
|
Between day 31 and 12-months post-procedure.
|
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
successful stent deployment at the target lesion in a variety of carotid morphologies
|
|
|
successful filter deployment and retrieval
|
|
|
<30% residual stenosis determined by angiography immediately post-stent placement and post-dilatation
|
|
|
endovascular access site complications, such as the need for surgical repair or blood transfusion
|
|
|
surgical site complications, such as wound infection or hematoma, that prolong hospital stay, require incision and drainage, or need blood transfusion
|
|
|
patency (< 50% restenosis) of the Cordis Nitinol Stent as determined by carotid ultrasound imaging within 48 hours, at six months, and one, two and three years post-procedure
|
|
|
independent neurologic assessments at 24 + 12 hours, thirty days, six months, and one, two and three years post-procedure (in addition to stroke scales, the development of any cranial nerve deficits will be recorded) - persistent neurologic deficits
|
|
|
thirty (30)-day and six (6)-month evaluation for disabling stroke
Time Frame: Day 30 and 6 months
|
Day 30 and 6 months
|
|
six (6)-month, one (1)-year, two (2)-year and three (3)-year composite of major adverse clinical events including death and ipsilateral stroke
Time Frame: 6 month and 1, 2, 3yr
|
6 month and 1, 2, 3yr
|
|
safety assessment of the ANGIOGUARD XP Emboli Capture Guidewire Device
|
|
|
presence of trapped material as determined by the interventionalist's visual inspection of the ANGIOGUARD XP filter basket following recapture at the completion of the procedure
|
|
|
laboratory analysis of trapped material contained in the ANGIOGUARD XP filter basket
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Publications and helpful links
The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.
General Publications
- Yadav JS, Wholey MH, Kuntz RE, Fayad P, Katzen BT, Mishkel GJ, Bajwa TK, Whitlow P, Strickman NE, Jaff MR, Popma JJ, Snead DB, Cutlip DE, Firth BG, Ouriel K; Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy Investigators. Protected carotid-artery stenting versus endarterectomy in high-risk patients. N Engl J Med. 2004 Oct 7;351(15):1493-501. doi: 10.1056/NEJMoa040127.
- Gurm HS, Yadav JS, Fayad P, Katzen BT, Mishkel GJ, Bajwa TK, Ansel G, Strickman NE, Wang H, Cohen SA, Massaro JM, Cutlip DE; SAPPHIRE Investigators. Long-term results of carotid stenting versus endarterectomy in high-risk patients. N Engl J Med. 2008 Apr 10;358(15):1572-9. doi: 10.1056/NEJMoa0708028.
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start
August 1, 2000
Study Completion (Actual)
August 1, 2005
Study Registration Dates
First Submitted
October 3, 2005
First Submitted That Met QC Criteria
October 3, 2005
First Posted (Estimate)
October 4, 2005
Study Record Updates
Last Update Posted (Estimate)
April 24, 2008
Last Update Submitted That Met QC Criteria
April 17, 2008
Last Verified
July 1, 2007
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- P98-5201
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.