Background: Percutaneous coronary intervention with stent implantation is a standard therapy for patients with acute coronary syndrome. The in-stent restenosis is still a problem. Recently, drug eluting stents reduce the incidence of this unfavorable event. The primary role of the polytetrafluoroethylene stent graft (PTFE) is management of coronary perforations, closure of coronary aneurysms, and in degenerated saphenous vein grafts. We compared these stents in native coronary vessels in patients with acute coronary syndrome with sirolimus and bare metal stents, for possible reduction of in-stent restenosis.
Methods and results: During the 6-month period 119 patients with acute coronary syndrome, were randomized to either stent graft group (n=40), sirolimus eluting stent group (n=39), or bare metal stent group (n=40). Demographic, angiographic and procedural characteristics were similar for all three groups. The incidence of 6-month major adverse coronary events was similar in all three groups. The target lesion revascularisation was higher in the bare metal stent group (P=0.044). The primary end-point, restenosis rate at six-month follow-up was higher in the bare metal stent group, compared with the stent graft and sirolimus eluting stent groups. The percent diameter stenosis in follow-up was significantly higher in bare metal stent group (P=0.005). The late loss was significantly lower in the sirolimus eluting stent group (0.23 mm), compared with the bare metal stent group (P= 0.034). There was a trend of lower late loss in the stent graft group, compared with bare metal stent group.
Conclusion: Three groups of stents implanted in patients with acute coronary syndrome (stent-graft, sirolimus and bare metal), did not differ regarding the incidence of major adverse cardiac events. Sirolimus-eluting stents had a lower incidence of in-stent restenosis in comparison with bare metal stent group. Stent graft implanted in native coronary arteries appears to be safe and efficient in patients with acute coronary syndrome, but a significant reduction of in-stent restenosis was not achieved.
Study Type
Enrollment
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Zagreb, Croatia, 10000
- University Hospital Zagreb
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- stent implantation in acute coronary syndrome
Exclusion Criteria:
- previous percutaneous coronary intervention or coronary artery bypass graft surgery
- multivessel, diffuse disease, tortuous vessel
- arteries less than 3 mm in diameter
- distal stenosis location
- left main and bifurcation lesions
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
|---|
|
Three groups of stents implanted in patients with acute coronary syndrome (stent-graft, sirolimus and bare metal), did not differ regarding the incidence of major adverse cardiac events.
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Maja Strozzi, MD, University Hospital Zagreb
Publications and helpful links
General Publications
- Keeley EC, Boura JA, Grines CL. Comparison of primary and facilitated percutaneous coronary interventions for ST-elevation myocardial infarction: quantitative review of randomised trials. Lancet. 2006 Feb 18;367(9510):579-88. doi: 10.1016/S0140-6736(06)68148-8. Erratum In: Lancet. 2006 May 20;367(9523):1656.
- Saia F, Lemos PA, Lee CH, Arampatzis CA, Hoye A, Degertekin M, Tanabe K, Sianos G, Smits PC, McFadden E, Hofma SH, van der Giessen WJ, de Feyter PJ, van Domburg RT, Serruys PW. Sirolimus-eluting stent implantation in ST-elevation acute myocardial infarction: a clinical and angiographic study. Circulation. 2003 Oct 21;108(16):1927-9. doi: 10.1161/01.CIR.0000096053.87580.CD. Epub 2003 Oct 13.
- Strozzi M, Anic D. Comparison of stent graft, sirolimus stent, and bare metal stent implanted in patients with acute coronary syndrome: clinical and angiographic follow-up. Croat Med J. 2007 Jun;48(3):348-52.
Study record dates
Study Major Dates
Study Start
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Estimate)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
- SG-SIR-BM-07
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.