- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT01819662
Optimised Pacing Program (OPT-pace)
Stratified Management of Patients With Pacemakers
Permanent pacemakers are a common treatment for slow heart beats. In the UK 300,000 people have a pacemaker, and each year another 36,000 receive them. All of these patients are usually seen yearly to have their device checked. However, pacemaker technology is now very reliable, batteries last well over 5 years, and many patients require their pacemaker only occasionally as a back-up. Each visit costs around £200 such that pacemaker follow-up cost the NHS around £50million per year. Most visits involve checking the battery and the leads which, in the absence of symptoms might be unnecessary.
Pacemaker patients are at risk of developing other problems including heart failure which puts them at higher risk of hospitalisation and death. For those under follow-up, no mechanism exists to identify whether they might have heart failure, and for those receiving new implants, it is unclear which will go on to develop heart failure. Also, whether optimal heart failure treatment with a multidisciplinary team reduces the chances that they will be hospitalised is also unproven.
Our study therefore has three main aims: 1) based on pacing indications and patient factors, to identify which patients are likely to develop complications and therefore which patients could be seen less frequently; 2) to validate and refine a simple risk score to help identify which patients in pacing clinic should undergo screening for heart failure; and 3) to establish whether such screening and subsequent optimisation of those with heart failure is clinically and cost-effective for reducing hospitalisation and death.
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Permanent pacemaker implantation is a safe, life-prolonging and cost-effective treatment for bradycardia. An estimated 300,000 people in the UK have a pacemaker and there are 36,000 new implants per year. Complications from pacemaker implantation occur in 5-15% of patients, mostly in the first six weeks. After six months new problems are very rare. Clinic follow-up of patients with a PPM usually occurs at six weeks, three months and then annually to monitor battery performance. Reprogramming is rarely required, and batteries reliably last at least five years. The tariff for pacemaker follow-up is £200 costing the National Health Service (NHS) £50 million per year.
The commonest and most under-recognised long-term complication of pacemaker implantation is pacemaker-related chronic heart failure (CHF) due to left ventricular systolic dysfunction, seen in up to 50% of patients. Published data examining the incidence and associations of pacemaker-related cardiac dysfunction consist of retrospective cross-sectional analyses or data taken from other studies rather than a-priori planned analyses. Our unique pilot data in almost 500 patients show that cardiac dysfunction is present in 40% of all pacemaker patients and confirm previous suggestions that it is more common in patients with an underlying predisposition, for example cardiovascular co-morbidities (including diabetes mellitus), with high rates of pacing and atrial fibrillation. Our data also demonstrate that patients with cardiac dysfunction and a pacemaker are not usually taking optimal medical therapy for their heart failure and suffer a 13% annual combined heart failure hospitalisation or death rate (compared to 6% in pacemaker patients without cardiac dysfunction, and ~8% in patients with CHF attending the Leeds Integrated Heart Failure Service). However, since patients with pacemakers were often excluded from the large studies of medical (and device) therapy of CHF, it is unclear whether optimisation of medical (and pacemaker) therapy in patients with pacemaker-related cardiac dysfunction can reduce mortality and hospitalisation. Pilot data from our clinic in 25 patients with a pacemaker and CHF, show that optimised medical therapy can lead to similar improvements in cardiac function as in CHF patients without a pacemaker.
The present project therefore includes three distinct, but closely related, work packages which will answer three questions;
- in patients receiving their first pacemaker, which clinical and pacing variables predict short, medium and long-term complications and is it therefore feasible, safe and cost-effective to individualise follow-up intervals;
- can we confirm and validate our previous observation that a model consisting of simple clinical and pacing variables identifies pacemaker patients at higher risk for cardiac dysfunction during a pacemaker-follow-up appointment and;
- does applying our risk model with subsequent optimisation of medication and pacemaker programming within a multidisciplinary heart failure service in those with heart failure lead to cost effective and clinically relevant reductions in mortality and hospitalisation?
Study Type
Enrollment (Actual)
Phase
- Phase 3
Contacts and Locations
Study Locations
-
-
-
Leeds, United Kingdom
- Leeds General Infirmary
-
-
Yorkshire
-
Bradford, Yorkshire, United Kingdom
- Bradford Hospitals NHS Foundation Trust
-
Harrogate, Yorkshire, United Kingdom
- Harrogate Hospital Foundation Trust
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Pacemaker implantation
Exclusion Criteria:
- Dementia, unwilling to fill in quality of life questionnaires, unwilling to sign consent form
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Placebo Comparator: Standard management
No echocardiogram
|
Usual care
|
|
Active Comparator: Enhanced standard management
Echocardiogram performed, with results to GP
|
Echocardiogram followed by letter to GP about results.
|
|
Active Comparator: Optimised heart failure management
Echocardiogram, followed by referral to comprehensive heart failure program for those with left ventricular dysfunction
|
Echocardiogram followed by referral to comprehensive heart failure service for those with left ventricular dysfunction
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Combined hospitalisation and mortality
Time Frame: 3 years
|
3 years
|
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Predictors of complications from pacemaker implantation
Time Frame: 3 years
|
3 years
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Predictors of cardiac dysfunction in pacemaker patients
Time Frame: 1-3 years
|
Who will develop cardiac dysfunction after permanent pacemaker implantation?
Who under follow-up has cardiac dysfunction and how can it be identified?
|
1-3 years
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Klaus K Witte, MD, University of Leeds
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- NIHR-CS-012-032
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.