Brain Radiation Exposure and Attenuation During Invasive Cardiology Procedures (BRAIN)

July 26, 2013 updated by: Ryan Reeves, University of California, San Diego

Brain Radiation Exposure and Attenuation During Invasive Cardiology Procedures.

Invasive cardiac procedures involve procedural guidance with x-rays in the form of fluoroscopy. X-ray exposure poses a potential risk of acute and long-term complications to staff involved in these procedures. Lead shields are placed between the operators (on their left side) and the x-ray source to limit exposure. However as the operator requires direct access to the patient and x-ray scatter occurs, full protection is not possible. Lead gowns, thyroid collars, and leaded glasses are typically worn to protect the body, thyroid, and eyes respectively, but their thickness is limited by their relatively heavy weight. Nevertheless this leaves the brain exposed. Further, interest in the risk of brain cancer in invasive cardiologists has re-emerged after a recent report of left-sided brain cancer in primary operators of interventional cardiology procedures. Lead caps have been tested in the past but the relatively heavyweight of lead has limited wide-spread implementation. The cap typically worn during invasive procedures is lightweight, has no significant x-ray absorption properties, and is worn to help maintain a sterile environment. A novel, lead-free cap, composed mainly of barium sulfate and bismuth oxide, has been developed that has been shown to absorb x-rays while being significantly lighter than lead. The investigators propose using multiple x-ray detectors to test exposure differences between the primary and secondary operators, the left side and right side of the head, and absorption via a lead-free cap.

Study Overview

Detailed Description

This is a prospective study evaluating radiation exposure to operators of invasive cardiovascular procedures at the UCSD Medical Center in La Jolla. Primary and secondary operators of cardiac catheterization procedures using fluoroscopy guidance, including cardiac catheterization, coronary angiography, and interventional procedures will wear multiple dosimeters to evaluate levels of radiation exposure. The primary and secondary operators will wear six dosimeters on their heads; three outside the non-lead attenuating cap and three underneath the cap. Above and beneath the cap, the dosimeters will be on the left side, in the center, and on the right side of the head. The dosimeters will be worn for a target of at least 50 procedures for each operator. The primary operators will be closest to the procedural site and the fluoroscopy unit for the majority of the procedure, while the secondary operators will be to the right side of the primary operators during the procedures. The operators will maintain this designation while participating in the study. All operators will continue to wear the dosimeters issued by the catheterization laboratory as part of standard radiation monitoring.

Each operator will be assigned six dosimeters, which will be secured within the cap at the time of assignment. The use of each cap and respective set of dosimeters will be recorded in a log book in the secure cardiac catheterization laboratory and associated with specific cardiac case numbers. Specific factors related to operator radiation exposure for each procedure will be recorded including: operator height, patient weight and BMI, dose area product (DAP), fluoroscopy time, length of procedure, type of procedure, access site, and complexity of procedure as determined by the attending physician. The operators will comment on the comfort of the cap using a semi-quantitative scale and the levels of exposure will be measured from the dosimeters. The operators will also be asked to compare and contrast the study cap with any other attenuating or non-attenuating cap that has been previously worn. At the conclusion of the study, statistical analysis will be performed to determine the differential levels of exposure between the primary and secondary operators, between different sides of the head, and the attenuation ability of the XPF cap. The dosimeters on the outside of the cap will serve as the control in evaluating the attenuating ability of the cap compared to the corresponding dosimeters on the inside. Each dosimeter location on the outside of the cap will be compared to the other locations for both the outside and the inside sets. And finally, the exposure measurements will be compared between the primary and secondary operators for each dosimeter location. The specific factors listed above that affect operator exposure will be taken into account as well.

Study Type

Observational

Enrollment (Actual)

11

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • California
      • La Jolla, California, United States, 92093
        • University of California, San Diego, Sulpizio Cardiovascular Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

We plan to enroll up to 12 invasive cardiologists routinely performing cardiac catheterization procedures at the UCSD Medical Center, La Jolla campus. We plan to monitor radiation exposure in at least 50 cases for each operator.

Description

Inclusion Criteria:

  • 18 years or older
  • Routinely performing cardiac catheterization procedures as the primary or secondary operators

Exclusion Criteria:

  • Cases with emergent indications including STEMI will be excluded
  • Cases consisting of solely right heart catheterization will be excluded

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
Differential radiation exposure from corresponding locations on the outside and inside of the non-lead attenuating cap.
Time Frame: Radiation exposure has been ongoing and will be assessed upon dosimeter measurement in within 1 month by an independent radiation monitoring service.
Radiation exposure has been ongoing and will be assessed upon dosimeter measurement in within 1 month by an independent radiation monitoring service.

Secondary Outcome Measures

Outcome Measure
Time Frame
Differential radiation exposure between the left and right sides of the heads of invasive cardiology operators.
Time Frame: Dosimeters measurement to be read/reported within one month.
Dosimeters measurement to be read/reported within one month.

Other Outcome Measures

Outcome Measure
Time Frame
Differential radiation exposure between primary and secondary operators of invasive cardiology procedures.
Time Frame: Dosimeters measurement to be read/reported within one month.
Dosimeters measurement to be read/reported within one month.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

January 1, 2013

Primary Completion (Actual)

July 1, 2013

Study Registration Dates

First Submitted

July 19, 2013

First Submitted That Met QC Criteria

July 26, 2013

First Posted (Estimate)

July 29, 2013

Study Record Updates

Last Update Posted (Estimate)

July 29, 2013

Last Update Submitted That Met QC Criteria

July 26, 2013

Last Verified

July 1, 2013

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Radiation Effects