The technical quality of coronary artery bypass anastomoses during coronary artery bypass grafting is often evaluated by measuring flow rate in grafts using transit time flowmetry. Unfortunately, flow rate and flow waveform are poor indicators of the anatomy of anastomoses. A better way to evaluate the anatomy of an anastomosis is 3-dimensional imaging. Three problems must be overcome in performing epicardial echocardiography on the beating heart:
- The transducer must be kept in a steady position relative to the anastomosis for 5 to 10 cardiac cycles to minimize frame-rate variability.
- Ultrasound gel must be kept in contact with the transducer and the region studied.
- The transducer must not cause any deformation of the vessels.
The investigators designed an ultrasound transducer positioning device, the Echoclip device (Aalborg Hospital, Aalborg, Denmark), which can stabilize the involved part of the myocardium on the beating heart, keep the gel at place, and position the ultrasound transducer correctly for imaging. The present study is a feasibility study with the aim to evaluate if the echoclip device facilitates imaging of coronary bypass anastomoses during coronary artery bypass surgery in humans to the same degree as was shown in animal studies. Ultrasonography will be used for visualizing all coronary anastomoses during 100 elective low-risk (logistic II EuroSCORE <6) on-pump coronary artery bypass procedures. It will be registered if the heel, the central portion and the toe of the anastomosis can be visualized in end-to-side and side-to-side anastomoses.Use of the echoclip devise will be considered a success if at least 80% of all parts of the anastomoses can be visualized either directly or by electronic reading using a special developed algorithm that may identify the inner border of the anastomoses.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Aalborg, Denmark, 9100
- Aalborg University Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Elective on-pump coronary artery bypass surgery
- Surgery planned to be performed by specialist in cardiac surgery.
- Logistic euroSCORE II <6%.
- Must be able to read and understand the Danish
- Written informed acceptance to participate
Exclusion Criteria:
- Planned off-pump surgery.
- Peroperativ conversion to off-pump surgery.
- Logistic EuroSCORE II ≥ 6.
- The patient do not understand written or spoken Danish.
- Surgery within 24 hours after admittance to hospital
- Patients in whom the surgeon wants to end the surgery in a hurry due to e.g. hemodynamic problems or peroperative complications.
- The surgeon is not a specialist in cardiac surgery, e.g. surgeon in training.
- Pregnant or brest feeding patient.
- No written acceptance to participate.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Echoclip device
Ultrasonography using the echoclip device
|
An ultrasound transducer positioning device, the Echoclip device (Aalborg Hospital, Aalborg,Denmark), which can stabilize the involved part of the myocardium on the beating heart, keep the gel at place, and position the ultrasound transducer correctly for imaging will be used for visualising the coronary bypass anastomoses during surgery
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Quality of periferal coronary artery bypass anastomotic structures
Time Frame: Peroperative
|
Ultrasonographic images of periferal coronary artery bypass anastomoses will be studied in order to evaluate if the area of anastomotic structures from various locations of the anastomoses (heel, central portion and the to toe) can be visualized directly on the screen using the echoclip device.
|
Peroperative
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Automatic quality control of periferal coronary artery bypass anastomotic structures
Time Frame: Peroperative
|
To quantify the anastomotic quality from epicardial utrasound images obtained peroperative, the area of anastomotic structures from various locations of the anastomoses (heel, central portion and the to toe) will be meassured using an automatic anastomosis segmentation algorithm to extract the area of the anastomotic structures.
The ultrasound images obtained peroperative will be analyzed in the Laboratory when 50 patients and 100 patients have been included in the study, respectively.
|
Peroperative
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Jan J Andreasen, MD, PhD, Aalborg University Hospital and Aalborg University
Publications and helpful links
General Publications
- Staalsen NH, Kjaergaard B, Andreasen JJ. A new technique facilitating intraoperative, high-frequency echocardiography of coronary bypass graft anastomoses. J Thorac Cardiovasc Surg. 2011 Jan;141(1):295-6. doi: 10.1016/j.jtcvs.2009.11.074. No abstract available.
- Andreasen JJ, Nohr D, Jorgensen AS, Haahr PE. Peroperative epicardial ultrasonography of distal coronary artery bypass graft anastomoses using a stabilizing device. A feasibility study. J Cardiothorac Surg. 2020 Jan 8;15(1):3. doi: 10.1186/s13019-020-1057-x.
- Andreasen JJ, Nohr D, Jorgensen AS. A case report on epicardial ultrasonography of coronary anastomoses using a stabilizing device without the use of ultrasound gel. J Cardiothorac Surg. 2019 Mar 13;14(1):59. doi: 10.1186/s13019-019-0882-2.
Study record dates
Study Major Dates
Study Start
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 0089Y
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.