Portable System for Non-intrusive Monitoring of Sleep

September 1, 2023 updated by: Philippe Van de Borne, Erasme University Hospital

Validation of a New Non-intrusive Technology for Detecting Sleep Apnea

Obstructive sleep apnea (OSA) is a prevalent kind of sleep-disordered breathing affecting one-seventh of the world's population. Almost 45 percent of this population suffers from mild to severe apnea. However, in many cases it remains undiagnosed, leading to increased health risks. Sleep-disordered breathing, as seen in OSA, can have serious long-term consequences, including sympathetic nervous system activation, sleep disturbances, heart remodeling, and cardiovascular disease development.

Polysomnography is the standard method for assessing sleep-breathing disorders, which requires the attachment of various sensors by a trained technician or a healthcare professional. However, if the diagnosis of OSA depends on referral to a sleep laboratory, and if the referral is reliant on symptoms of an OSA syndrome, then current screening approaches may exclude a large population of individuals at risk. Besides, the number of sleep centers and caregivers is limited, and the associated costs are high. Therefore, alternative techniques allowing home monitoring are necessary.

The goal of this observational study is to evaluate the accuracy of the Kinocardiography technique in detecting apneic episodes during sleep and comparing the results with the gold standard polysomnography in 47 patients suffering from obstructive sleep apnea. We hypothesize that this device is able to detect sleep-disordered breathing events, and thus to compute the apnea-hypopnea index, with an accuracy that is close to that of the polysomnography.

Participants who meet the criteria will be invited to participate in this protocol and do both polysomnography and kinocardiography records simultaneously at night during sleep.

Study Overview

Status

Not yet recruiting

Conditions

Intervention / Treatment

Detailed Description

  1. Study Glossary

    • BCG = Ballistocardiography
    • ECG = Electrocardiography
    • PSG = Polysomnography
    • SCG = Seismocardiography
    • KCG = Kinocardiography
  2. Monitoring Technique

    Ballistocardiography (BCG) and seismocardiography (SCG) are two promising technologies for monitoring vital signs during sleep. BCG measures body movements caused by blood flow ejection at each cardiac contraction, while SCG detects micro-vibrations from heart contractions on the chest surface. These low-cost and unobtrusive technologies have been used in various sleep studies, showing promise in vital sign recording, detecting abnormal breathing episodes, and studying the effects of disease and environmental conditions. However, more research and replication of studies are required for widespread application.

    Kinocardiography:

    Kinocardiography (KCG) is a technique that combines BCG and SCG with electrocardiography (ECG). The BCG module is placed close to the subject's center of mass in the lumbar vertebrae. The SCG module is placed on the sternum beneath the clavicle, close to the heart and major blood vessels. Each module is a MOVESENSE device that incorporates a three-axis accelerometer and three-axis gyroscope sensor and is attached to the body using standard sticky gel electrodes and a belt. The overall system is remotely controlled via a Bluetooth-connected smartphone or tablet. This device allows the measurement of the micro-accelerations induced by the cardiac activity at the body's surface. By computing these accelerations, it is possible to calculate other parameters, such as the kinetic energies associated with the contraction of the heart.

    Polysomnography:

    Polysomnography (PSG) includes various techniques to monitor neurophysiological, cardiopulmonary, and other physiologic parameters simultaneously. PSG uses electroencephalogram, electrooculogram, electromyogram, ECG, pulse oximetry, airflow, and respiratory effort to identify the underlying causes of sleep disturbances.

  3. Safety Reporting

    The MOVESENSE device will be used in this study to collect ECG and signals from accelerometers and gyroscopes. Once this data has been collected, then the analysis will be conducted within the Erasme hospital. This device is a CE-marked medical device (https://ec.europa.eu/tools/eudamed/#/screen/search-device/8d619c90-794a-4564-9a54-829aefa9c707).

    The hazard probability is extremely low, and its severity is minimal (the only possibility is feeling uncomfortable with the electrodes' gel on the skin).

    If a subject becomes uncomfortable, they can call the nurse/operator throughout the measurement and will be able to let the operator know right away if they want to stop the measurement.

  4. Strategies for participant recruitment

The recruitment will be done among the subjects referred for PSG as required by their medical condition. This study will not affect in any manner the regular medical care of the patients admitted to the sleep laboratory. Subjects will be recruited within the routine of the sleep laboratory in the Erasme hospital. Subjects who meet the criteria will be invited to participate in this protocol and do both PSG and KCG records simultaneously.

Study Type

Observational

Enrollment (Estimated)

47

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Bruxelles, Belgium, 1070
        • Erasme Hospital
        • Contact:
        • Sub-Investigator:
          • Paniz Balali, MSc
        • Principal Investigator:
          • Philippe van de Borne, PhD. MD.

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Sampling Method

Non-Probability Sample

Study Population

Patients admitted for complaints of sleep disturbances with no prior treatment for sleep apnea and no known cardiovascular pathologies.

Description

Inclusion Criteria:

  • The participants should be adult patients who come to Erasme Hospital's sleep department with complaints about sleep disturbances.
  • 18 < age <70
  • BMI < 35 kg/m2

Exclusion Criteria:

  • Being under any kind of obstructive sleep apnea treatment (cPAP therapy, etc.)
  • Having been diagnosed with Atrial fibrillation, significant valvular heart disease, or ventricular dysfunction
  • Age <18 or age > 70
  • BMI > 35 kg/m2

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Obstructive sleep apnea patients

Patients admitted for complaints of sleep disturbances with no prior significant cardiovascular disease.

Inclusion criteria:

  • 18 < age <70
  • BMI < 35 kg/m2

Exclusion criteria:

  • Being under any kind of OSA treatment (cPAP therapy, etc.)
  • Having been diagnosed with Atrial fibrillation, significant valvular heart disease, or ventricular dysfunction
  • Age <18 or age > 70
  • BMI > 35 kg/m2
This device can be attached to the skin (on the chest and center of mass) during sleep using a belt and adhesive electrodes.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Sensitivity and Specificity of MOVESENSE sensor in detecting patients suffering from apnea
Time Frame: During 1 night (~8hours)
Sensitivity and Specificity of MOVESENSE sensor in detecting patients suffering from apnea based on the apnea-hypopnea index (AHI) and different grades of severity: AHI<5; 5<AHI<15; 15<AHI<30; 30<AHI.
During 1 night (~8hours)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Variation of kinetic energy during apneic episodes
Time Frame: During 1 night (~8hours)
Measurement of changes in seismocardiography/ballistocardiography integral of kinetic energy (in mJ.s) during and immediately after an apneic episode.
During 1 night (~8hours)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Philippe van de Borne, Professor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

September 20, 2023

Primary Completion (Estimated)

February 29, 2024

Study Completion (Estimated)

February 29, 2024

Study Registration Dates

First Submitted

August 16, 2023

First Submitted That Met QC Criteria

September 1, 2023

First Posted (Actual)

September 8, 2023

Study Record Updates

Last Update Posted (Actual)

September 8, 2023

Last Update Submitted That Met QC Criteria

September 1, 2023

Last Verified

September 1, 2023

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe