Measuring Force During Subpial Resection Procedure Using a Novel Ex Vivo Calf Brain Model With Integrated Sensor

June 10, 2026 updated by: Rolando Del Maestro, McGill University

Neurosurgery is a high-stakes surgical specialty where errors can result in significant morbidity. The amount of force applied simultaneously on the brain with multiple different instruments during complex neurosurgical procedures is a critical safety metric that, to the investigators' knowledge, has not been previously measured in a realistic operative environment.

The investigators have therefore developed a simulation platform integrating an ex vivo calf brain and a 3D-printed skull model attached to a force sensor capable of capturing real-time forces applied to the brain. A case series study will be conducted to evaluate the pattern of force applied. Medical students, neurosurgical residents, and staff neurosurgeons from McGill University will be recruited to perform subpial resections using our ex vivo calf brain simulation platform. The forces applied by the microscissors, bipolar forceps, and ultrasonic aspirator onto the brain will be captured. This study aims to demonstrate the spectrum of force applied during a neurosurgical procedure using an ex vivo calf brain model.

Study Overview

Status

Recruiting

Conditions

Detailed Description

Background and Rationale: The subpial resection technique is a complex neurosurgical procedure that is essential for brain tumor and epilepsy surgery. However, opportunities for trainees to gain hands-on experience with this procedure without risk to patient safety are limited. The force applied on the brain during tool-tissue contact is a critical factor impacting patient safety. While virtual simulation platforms enable force monitoring, ex vivo animal brains cannot readily capture quantitative data. The investigators have therefore developed a prototype of a simulation platform that integrates a force sensor and a calf brain and can accurately detect real-time forces during simulated subpial resections. This study seeks to gauge the force spectrum using this ex vivo calf brain force detection system.

Hypothesis: The simulation platform will accurately measure forces applied by novice, intermediate, and expert participants with surgical instruments on an ex vivo calf brain during simulated subpial resection procedures.

Primary Objective: To measure the forces applied by novice, intermediate, and expert participants during simulated ex vivo subpial resection procedures.

Setting: Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.

Participants:

Neurosurgeons (experts): Staff neurosurgeons at McGill University specializing in oncology, epilepsy, pediatric, or vascular neurosurgery

Neurosurgical residents (trainees): Neurosurgical residents at McGill University

Medical students (novices): Students enrolled in medical school at McGill University

Design: A cross-sectional case series study.

Methodology: This study was approved by the McGill University Health Centre Research Ethics Board, Neurosciences-Psychiatry. A case series study will be conducted where medical students, neurosurgical residents, and staff neurosurgeons from McGill University will be recruited to perform subpial resection tasks on an ex vivo calf brain model. Calf brains will be placed in a 3D-printed skull model to mimic a realistic human operative environment. The 3D-printed skull model was prototyped from a publicly available CT scan obtained from Embodi3D, an open-access medical imaging repository, and reconstructed in 3D using the open-source software 3D Slicer version 5.10.0. A 6-degree-of-freedom force/torque sensor (Nano17 IP68, ATI Industrial Automation Inc., North Carolina, USA) and a USB data acquisition board (NI-6210, National Instruments Inc., Texas, USA) will be used to measure real-time forces applied to the brain. Participants will use microscissors, bipolar forceps, and a SONOPET ultrasonic aspirator (Stryker, Portage, Michigan, USA) to perform simulated procedures. The tasks will be performed using an OPMI pico surgical microscope (ZEISS, Jena, Germany) and video-recorded using a Blackfly S GigE embedded microscope camera (FLIR, Wilsonville, Oregon, USA), allowing a broader instrument view for evaluation of intraoperative and postoperative performance.

Study Procedure: Upon arrival, participants will read and sign an informed consent form. They will then fill out a pre-trial questionnaire assessing their demographic characteristics (e.g., sex, gender, age, institutional affiliation, etc.). Each participant will receive standardized instructions on instrument use and function and be presented with an image outlining the location of pial cuts and the subpial resections on the ex vivo calf brain in front of them. Participants will adjust the operating microscope according to their preferences. The subpial resection experiment will be divided into three subsequent tasks. The goal is to obtain a noise-free and specific force measurement for each of the major instruments/maneuvers in a standard subpial resection. The first task entails using microscissors to create a 2-cm pial cut in ten different gyri across a calf brain hemisphere (n = 10). The time allocated for this task is 30 seconds for each cut. The second task involves utilizing bipolar forceps to grasp and lift the edge of the pia where cuts are made with the microscissors in task 1. A repetitive lift and hold maneuver will be repeated five times assuming a right to left direction across the pial incision line in 5-second intervals using the left hand. This will be repeated across each of the ten different pial cuts (n = 50). The time allocated for this task is maximum of one minute for each pial defect. Finally, an ultrasonic aspirator in the dominant (right) hand along with the bipolar in the opposite hand will be employed to perform subpial resection at three out of the ten pial cuts originally made in task 1 (n = 3). Each of the three spots would undergo subpial resection for an allocated time of 3 minutes across separate recordings.

Significance: This study will provide the first insights into a realistic operative environment where it will be possible to monitor the force applied on the brain.

Study Type

Observational

Enrollment (Estimated)

9

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • Quebec
      • Montreal, Quebec, Canada, H3A 2B4
        • Recruiting
        • Neuro Imaging and Surgical Technologies Lab, Department of Neurology and Neurosurgery, Montreal Neurological Institute and Hospital, McGill University
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

Yes

Sampling Method

Non-Probability Sample

Study Population

Staff neurosurgeons, neurosurgical residents, and medical students from McGill University

Description

Inclusion Criteria:

  • Right-handed medical students, neurosurgical residents, and staff neurosurgeons from McGill University

Exclusion Criteria:

  • Left-handed individuals

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Forces applied to the brain during each simulated subpial resection procedure step
Time Frame: 1 day of study
Throughout each simulated ex vivo subpial resection procedure, forces applied to the brain during tool-tissue contact will be measured by the force/torque sensor in grams and Newtons.
1 day of study

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Rolando F. Del Maestro, MD, PhD, Neurosurgical Simulation and Artificial Intelligence Learning Centre, McGill University
  • Study Director: Amir Hooshiar, PhD, Surgical Performance Enhancement and Robotics Centre, McGill University
  • Study Director: D. Louis Collins, PhD, Neuro Imaging and Surgical Technologies Lab, McGill University

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

June 1, 2026

Primary Completion (Estimated)

July 1, 2026

Study Completion (Estimated)

July 1, 2026

Study Registration Dates

First Submitted

June 10, 2026

First Submitted That Met QC Criteria

June 10, 2026

First Posted (Actual)

June 16, 2026

Study Record Updates

Last Update Posted (Actual)

June 16, 2026

Last Update Submitted That Met QC Criteria

June 10, 2026

Last Verified

June 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • 2018 4395, Trial 1

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

YES

IPD Sharing Supporting Information Type

  • STUDY_PROTOCOL
  • SAP
  • ICF
  • ANALYTIC_CODE
  • CSR

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Surgical Education