Measuring Force During Subpial Resection Procedure Using a Novel Ex Vivo Calf Brain Model With Integrated Sensor

10. Juni 2026 aktualisiert von: Rolando Del Maestro, McGill University

Neurosurgery is a high-stakes surgical specialty where errors can result in significant morbidity. The amount of force applied simultaneously on the brain with multiple different instruments during complex neurosurgical procedures is a critical safety metric that, to the investigators' knowledge, has not been previously measured in a realistic operative environment.

The investigators have therefore developed a simulation platform integrating an ex vivo calf brain and a 3D-printed skull model attached to a force sensor capable of capturing real-time forces applied to the brain. A case series study will be conducted to evaluate the pattern of force applied. Medical students, neurosurgical residents, and staff neurosurgeons from McGill University will be recruited to perform subpial resections using our ex vivo calf brain simulation platform. The forces applied by the microscissors, bipolar forceps, and ultrasonic aspirator onto the brain will be captured. This study aims to demonstrate the spectrum of force applied during a neurosurgical procedure using an ex vivo calf brain model.

Studienübersicht

Status

Rekrutierung

Detaillierte Beschreibung

Background and Rationale: The subpial resection technique is a complex neurosurgical procedure that is essential for brain tumor and epilepsy surgery. However, opportunities for trainees to gain hands-on experience with this procedure without risk to patient safety are limited. The force applied on the brain during tool-tissue contact is a critical factor impacting patient safety. While virtual simulation platforms enable force monitoring, ex vivo animal brains cannot readily capture quantitative data. The investigators have therefore developed a prototype of a simulation platform that integrates a force sensor and a calf brain and can accurately detect real-time forces during simulated subpial resections. This study seeks to gauge the force spectrum using this ex vivo calf brain force detection system.

Hypothesis: The simulation platform will accurately measure forces applied by novice, intermediate, and expert participants with surgical instruments on an ex vivo calf brain during simulated subpial resection procedures.

Primary Objective: To measure the forces applied by novice, intermediate, and expert participants during simulated ex vivo subpial resection procedures.

Setting: Montreal Neurological Institute and Hospital, McGill University, Montreal, Quebec, Canada.

Participants:

Neurosurgeons (experts): Staff neurosurgeons at McGill University specializing in oncology, epilepsy, pediatric, or vascular neurosurgery

Neurosurgical residents (trainees): Neurosurgical residents at McGill University

Medical students (novices): Students enrolled in medical school at McGill University

Design: A cross-sectional case series study.

Methodology: This study was approved by the McGill University Health Centre Research Ethics Board, Neurosciences-Psychiatry. A case series study will be conducted where medical students, neurosurgical residents, and staff neurosurgeons from McGill University will be recruited to perform subpial resection tasks on an ex vivo calf brain model. Calf brains will be placed in a 3D-printed skull model to mimic a realistic human operative environment. The 3D-printed skull model was prototyped from a publicly available CT scan obtained from Embodi3D, an open-access medical imaging repository, and reconstructed in 3D using the open-source software 3D Slicer version 5.10.0. A 6-degree-of-freedom force/torque sensor (Nano17 IP68, ATI Industrial Automation Inc., North Carolina, USA) and a USB data acquisition board (NI-6210, National Instruments Inc., Texas, USA) will be used to measure real-time forces applied to the brain. Participants will use microscissors, bipolar forceps, and a SONOPET ultrasonic aspirator (Stryker, Portage, Michigan, USA) to perform simulated procedures. The tasks will be performed using an OPMI pico surgical microscope (ZEISS, Jena, Germany) and video-recorded using a Blackfly S GigE embedded microscope camera (FLIR, Wilsonville, Oregon, USA), allowing a broader instrument view for evaluation of intraoperative and postoperative performance.

Study Procedure: Upon arrival, participants will read and sign an informed consent form. They will then fill out a pre-trial questionnaire assessing their demographic characteristics (e.g., sex, gender, age, institutional affiliation, etc.). Each participant will receive standardized instructions on instrument use and function and be presented with an image outlining the location of pial cuts and the subpial resections on the ex vivo calf brain in front of them. Participants will adjust the operating microscope according to their preferences. The subpial resection experiment will be divided into three subsequent tasks. The goal is to obtain a noise-free and specific force measurement for each of the major instruments/maneuvers in a standard subpial resection. The first task entails using microscissors to create a 2-cm pial cut in ten different gyri across a calf brain hemisphere (n = 10). The time allocated for this task is 30 seconds for each cut. The second task involves utilizing bipolar forceps to grasp and lift the edge of the pia where cuts are made with the microscissors in task 1. A repetitive lift and hold maneuver will be repeated five times assuming a right to left direction across the pial incision line in 5-second intervals using the left hand. This will be repeated across each of the ten different pial cuts (n = 50). The time allocated for this task is maximum of one minute for each pial defect. Finally, an ultrasonic aspirator in the dominant (right) hand along with the bipolar in the opposite hand will be employed to perform subpial resection at three out of the ten pial cuts originally made in task 1 (n = 3). Each of the three spots would undergo subpial resection for an allocated time of 3 minutes across separate recordings.

Significance: This study will provide the first insights into a realistic operative environment where it will be possible to monitor the force applied on the brain.

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

9

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studienorte

    • Quebec
      • Montreal, Quebec, Kanada, H3A 2B4
        • Rekrutierung
        • Neuro Imaging and Surgical Technologies Lab, Department of Neurology and Neurosurgery, Montreal Neurological Institute and Hospital, McGill University
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Ja

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

Staff neurosurgeons, neurosurgical residents, and medical students from McGill University

Beschreibung

Inclusion Criteria:

  • Right-handed medical students, neurosurgical residents, and staff neurosurgeons from McGill University

Exclusion Criteria:

  • Left-handed individuals

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Forces applied to the brain during each simulated subpial resection procedure step
Zeitfenster: 1 day of study
Throughout each simulated ex vivo subpial resection procedure, forces applied to the brain during tool-tissue contact will be measured by the force/torque sensor in grams and Newtons.
1 day of study

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Rolando F. Del Maestro, MD, PhD, Neurosurgical Simulation and Artificial Intelligence Learning Centre, McGill University
  • Studienleiter: Amir Hooshiar, PhD, Surgical Performance Enhancement and Robotics Centre, McGill University
  • Studienleiter: D. Louis Collins, PhD, Neuro Imaging and Surgical Technologies Lab, McGill University

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Juni 2026

Primärer Abschluss (Geschätzt)

1. Juli 2026

Studienabschluss (Geschätzt)

1. Juli 2026

Studienanmeldedaten

Zuerst eingereicht

10. Juni 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

10. Juni 2026

Zuerst gepostet (Tatsächlich)

16. Juni 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

16. Juni 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

10. Juni 2026

Zuletzt verifiziert

1. Juni 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 2018 4395, Trial 1

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

JA

Art der unterstützenden IPD-Freigabeinformationen

  • STUDIENPROTOKOLL
  • SAFT
  • ICF
  • ANALYTIC_CODE
  • CSR

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Chirurgische Ausbildung

Abonnieren