- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT02880839
Digital Navigation Enhances Cervical Pedicle Screw Placement Accuracy and Safety
Digital Navigation Enhances Cervical Pedicle Screw Placement Accuracy and Safety: A Randomized Controlled Trial
Přehled studie
Postavení
Podmínky
Detailní popis
History and current status of related studies
The cervical pedicle is a tiny structure adjacent to important tissues including the spinal cord and vertebral artery. Cervical pedicle screw internal fixation is the conventional treatment for cervical spine fracture, and the technique provides acceptable internal fixation; however, current manipulation methods result in high pedicle screw penetration rates, a high risk of damage to peripheral vessels and nerves, and high rates of postoperative deformity. Improved techniques and minimally invasive methods such as transcutaneous pedicle screw implantation have been designed to effectively reduce surgery-related injury while maintaining the accuracy and safety of pedicle screw implantation. Unfortunately, there is no unified standard regarding implantation of cervical pedicle screws, and many pedicle screw implantation methods are used including partial cervical lamina excision and pipeline-dredge discharge. However, both of these techniques are clinically limited because of poor maneuverability. Digital navigation is an emerging technique based on the discrete-accumulation principle. The technique integrates computer methods, numerical control, laser and new materials, and provides a new digital technique for confirming the location and orientation of cervical pedicle screws, ensuring safe surgical operation.
Features different from other related studies
Previous studies focused primarily on investigating the curative effects of pedicle screw implantation in cervical spine fracture. To the best of the investigators knowledge, there are no studies of cervical spine fracture treatment by digital navigation-assisted cervical pedicle screw placement before June 2006 in Web of Science. The investigators located two similar articles (Cervical Spondylotic Myelopathy Surgical Trial (identifier: NCT02076113) and Slotted Hole Versus Fixed Hole C-Tek (identifier: NCT00585923)) in a search of ClinicalTrials.gov up to June 2006. The outcome measures in these two studies included bony fusion Short Form 36 and the physical component score. In contrast to these two studies regarding inclusion criteria and grouping, the investigators study was designed to investigate the accuracy and safety of digital navigation-assisted cervical pedicle screw placement, hoping to provide valuable quantitative evidence for the clinical application of this technique.
Adverse events
Possible adverse events included any expected or unexpected symptoms. If severe adverse events occurred, their details including the date of occurrence and measures taken to treat the adverse events were reported to the principal investigator and the institutional review board within 24 hours.
Data collection, management, analysis and open access
Data collection: Case report forms with demographic data, disease diagnosis, accompanying diseases, drug allergy history, and adverse events were collected, processed using Epidata software (Epidata Association, Odense, Denmark), collated, and then recorded electronically by data managers using a double-data entry strategy.
Data management: The locked electronic database was accessible and locked only by the project manager, and was not altered. Paper and electronic data regarding screening, informed consent, and clinical outcomes have been preserved at the Affiliated Hospital of Nantong University, China.
Data analysis: The electronic database was statistically analyzed by a professional statistician who created an outcome analysis report that was submitted to the lead researchers. An independent data monitoring committee supervised and managed the trial data, ensuring a scientific and stringent trial to yield accurate and complete data.
Data open access: Anonymized trial data was published at http://www.figshare.com.
Statistical analysis
Statistical analysis was performed by a statistician using SPSS 19.0 software (SPSS Inc.) and followed the intention-to-treat principle. Normally distributed measurement data was expressed as mean, standard deviation, and minimums and maximums. Non-normally distributed measurement data were expressed as lower quartile (q1), and median and upper quartile (q3). The Kruskal-Wallis H-test was used to compare the visual analogue scale spine scores among the three groups, and Fisher's exact test was used to compare the degree of bony fusion of the atlantoaxial joint and the incidence of adverse reactions. P < 0.05 was considered statistically significant.
Typ studie
Zápis (Aktuální)
Fáze
- Nelze použít
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Fracture of the posterior column of the cervical spine or fracture of the anterior-posterior column of the cervical spine without severe vertebral body injury
- Non-traumatic cervical lamina destabilization, including metastatic tumor and rheumatoid arthritis
- Kyphotic deformity after cervical lamina resection
- Segmental destabilization after nerve root or spinal cord decompression
- Subjected to revision after anterior cervical spine surgery
- Scheduled to undergo internal fixation by cervical pedicle screw
- Age approximately 62 years
- Either sex
- Provision of signed informed consent to participate in the trial
Exclusion Criteria:
- Cervical pedicle injury resulting from trauma or tumor
- Severe osteoporosis
- Anatomical variation of the vertebral artery
- Unable or declined to proceed with internal fixation by pedicle screws
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
---|---|
Experimentální: Partial cervical lamina excision group
Patients in the cervical lamina partial excision group underwent partial cervical lamina excision and cervical pedicle screw internal fixation.
|
Patients with cervical fracture were assigned to undergo partial cervical lamina excision and cervical pedicle screw internal fixation.
|
Experimentální: Pipeline-dredge discharge group
Patients in the pipeline-dredge discharge group underwent pipeline-dredge discharge and cervical pedicle screw internal fixation.
|
Patients with cervical fracture were assigned to undergo pipeline-dredge discharge and cervical pedicle screw internal fixation.
|
Experimentální: Digital navigation group
Patients in the digital navigation group underwent digital navigation-assisted cervical pedicle placement.
|
Patients with cervical fracture were assigned to undergo digital navigation assisted cervical pedicle screw placement.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
---|---|---|
the penetration degree of the cervical pedicle screws
Časové okno: 12 months after internal fixation
|
According to whether screws penetrated the pedicle and the degree of penetration, screw insertion was graded in three levels: grade I, pedicle screws do not penetrate the pedicular cortex; grade II, screw threads penetrate the cortex at the isthmic portion of the pedicle (no more than 1/4 length of the screw diameter); grade III, screws obviously penetrate the cortex at the isthmic portion of the pedicle (> 1/4 length of the screw diameter) with risk of peripheral nerve and vessel injury, and poor stabilization of the internal fixation.
|
12 months after internal fixation
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
---|---|---|
bony fusion rate of the atlantoaxial joint
Časové okno: 12 and 36 months after internal fixation
|
To evaluate fracture healing.
Bone fusion rate in the atlantoaxial joint was calculated as the percentage of patients with bony fusion of the atlantoaxial joint divided by the total patient number in each group.
|
12 and 36 months after internal fixation
|
Visual analogue scale spine score
Časové okno: prior to and 12 and 36 months after internal fixation
|
To evaluate cervical neck pain.
The visual analogue scale spine score ranges
|
prior to and 12 and 36 months after internal fixation
|
American Spinal Injury Association Classification
Časové okno: prior to and 12 and 36 months after internal fixation
|
To evaluate improvements in neurological function
|
prior to and 12 and 36 months after internal fixation
|
incidence of adverse events
Časové okno: 12 and 36 months after internal fixation
|
To evaluate the safety of each pedicle screw implantation method.
The incidence of adverse events was calculated as the percentage of patients developing adverse events divided by the total patient number in each group.
|
12 and 36 months after internal fixation
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Vrchní vyšetřovatel: Junjie Guan, Master, Affiliated Hospital Of Nantong University
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Očekávaný)
Dokončení studie (Očekávaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- NantongU_001
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .