此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Digital Navigation Enhances Cervical Pedicle Screw Placement Accuracy and Safety

2016年8月25日 更新者:Junjie Guan、Nantong University

Digital Navigation Enhances Cervical Pedicle Screw Placement Accuracy and Safety: A Randomized Controlled Trial

To compare the internal fixation results of three pedicle screw implantation methods and investigated the accuracy and safety of digital navigation-assisted pedicle screw placement.

研究概览

详细说明

History and current status of related studies

The cervical pedicle is a tiny structure adjacent to important tissues including the spinal cord and vertebral artery. Cervical pedicle screw internal fixation is the conventional treatment for cervical spine fracture, and the technique provides acceptable internal fixation; however, current manipulation methods result in high pedicle screw penetration rates, a high risk of damage to peripheral vessels and nerves, and high rates of postoperative deformity. Improved techniques and minimally invasive methods such as transcutaneous pedicle screw implantation have been designed to effectively reduce surgery-related injury while maintaining the accuracy and safety of pedicle screw implantation. Unfortunately, there is no unified standard regarding implantation of cervical pedicle screws, and many pedicle screw implantation methods are used including partial cervical lamina excision and pipeline-dredge discharge. However, both of these techniques are clinically limited because of poor maneuverability. Digital navigation is an emerging technique based on the discrete-accumulation principle. The technique integrates computer methods, numerical control, laser and new materials, and provides a new digital technique for confirming the location and orientation of cervical pedicle screws, ensuring safe surgical operation.

Features different from other related studies

Previous studies focused primarily on investigating the curative effects of pedicle screw implantation in cervical spine fracture. To the best of the investigators knowledge, there are no studies of cervical spine fracture treatment by digital navigation-assisted cervical pedicle screw placement before June 2006 in Web of Science. The investigators located two similar articles (Cervical Spondylotic Myelopathy Surgical Trial (identifier: NCT02076113) and Slotted Hole Versus Fixed Hole C-Tek (identifier: NCT00585923)) in a search of ClinicalTrials.gov up to June 2006. The outcome measures in these two studies included bony fusion Short Form 36 and the physical component score. In contrast to these two studies regarding inclusion criteria and grouping, the investigators study was designed to investigate the accuracy and safety of digital navigation-assisted cervical pedicle screw placement, hoping to provide valuable quantitative evidence for the clinical application of this technique.

Adverse events

Possible adverse events included any expected or unexpected symptoms. If severe adverse events occurred, their details including the date of occurrence and measures taken to treat the adverse events were reported to the principal investigator and the institutional review board within 24 hours.

Data collection, management, analysis and open access

Data collection: Case report forms with demographic data, disease diagnosis, accompanying diseases, drug allergy history, and adverse events were collected, processed using Epidata software (Epidata Association, Odense, Denmark), collated, and then recorded electronically by data managers using a double-data entry strategy.

Data management: The locked electronic database was accessible and locked only by the project manager, and was not altered. Paper and electronic data regarding screening, informed consent, and clinical outcomes have been preserved at the Affiliated Hospital of Nantong University, China.

Data analysis: The electronic database was statistically analyzed by a professional statistician who created an outcome analysis report that was submitted to the lead researchers. An independent data monitoring committee supervised and managed the trial data, ensuring a scientific and stringent trial to yield accurate and complete data.

Data open access: Anonymized trial data was published at http://www.figshare.com.

Statistical analysis

Statistical analysis was performed by a statistician using SPSS 19.0 software (SPSS Inc.) and followed the intention-to-treat principle. Normally distributed measurement data was expressed as mean, standard deviation, and minimums and maximums. Non-normally distributed measurement data were expressed as lower quartile (q1), and median and upper quartile (q3). The Kruskal-Wallis H-test was used to compare the visual analogue scale spine scores among the three groups, and Fisher's exact test was used to compare the degree of bony fusion of the atlantoaxial joint and the incidence of adverse reactions. P < 0.05 was considered statistically significant.

研究类型

介入性

注册 (实际的)

76

阶段

  • 不适用

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 至 65年 (成人、年长者)

接受健康志愿者

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Fracture of the posterior column of the cervical spine or fracture of the anterior-posterior column of the cervical spine without severe vertebral body injury
  • Non-traumatic cervical lamina destabilization, including metastatic tumor and rheumatoid arthritis
  • Kyphotic deformity after cervical lamina resection
  • Segmental destabilization after nerve root or spinal cord decompression
  • Subjected to revision after anterior cervical spine surgery
  • Scheduled to undergo internal fixation by cervical pedicle screw
  • Age approximately 62 years
  • Either sex
  • Provision of signed informed consent to participate in the trial

Exclusion Criteria:

  • Cervical pedicle injury resulting from trauma or tumor
  • Severe osteoporosis
  • Anatomical variation of the vertebral artery
  • Unable or declined to proceed with internal fixation by pedicle screws

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Partial cervical lamina excision group
Patients in the cervical lamina partial excision group underwent partial cervical lamina excision and cervical pedicle screw internal fixation.
Patients with cervical fracture were assigned to undergo partial cervical lamina excision and cervical pedicle screw internal fixation.
实验性的:Pipeline-dredge discharge group
Patients in the pipeline-dredge discharge group underwent pipeline-dredge discharge and cervical pedicle screw internal fixation.
Patients with cervical fracture were assigned to undergo pipeline-dredge discharge and cervical pedicle screw internal fixation.
实验性的:Digital navigation group
Patients in the digital navigation group underwent digital navigation-assisted cervical pedicle placement.
Patients with cervical fracture were assigned to undergo digital navigation assisted cervical pedicle screw placement.
其他名称:
  • Digital navigation system

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
the penetration degree of the cervical pedicle screws
大体时间:12 months after internal fixation
According to whether screws penetrated the pedicle and the degree of penetration, screw insertion was graded in three levels: grade I, pedicle screws do not penetrate the pedicular cortex; grade II, screw threads penetrate the cortex at the isthmic portion of the pedicle (no more than 1/4 length of the screw diameter); grade III, screws obviously penetrate the cortex at the isthmic portion of the pedicle (> 1/4 length of the screw diameter) with risk of peripheral nerve and vessel injury, and poor stabilization of the internal fixation.
12 months after internal fixation

次要结果测量

结果测量
措施说明
大体时间
bony fusion rate of the atlantoaxial joint
大体时间:12 and 36 months after internal fixation
To evaluate fracture healing. Bone fusion rate in the atlantoaxial joint was calculated as the percentage of patients with bony fusion of the atlantoaxial joint divided by the total patient number in each group.
12 and 36 months after internal fixation
Visual analogue scale spine score
大体时间:prior to and 12 and 36 months after internal fixation
To evaluate cervical neck pain. The visual analogue scale spine score ranges
prior to and 12 and 36 months after internal fixation
American Spinal Injury Association Classification
大体时间:prior to and 12 and 36 months after internal fixation
To evaluate improvements in neurological function
prior to and 12 and 36 months after internal fixation
incidence of adverse events
大体时间:12 and 36 months after internal fixation
To evaluate the safety of each pedicle screw implantation method. The incidence of adverse events was calculated as the percentage of patients developing adverse events divided by the total patient number in each group.
12 and 36 months after internal fixation

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Junjie Guan, Master、Affiliated Hospital of Nantong University

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2013年9月1日

初级完成 (预期的)

2016年12月1日

研究完成 (预期的)

2017年12月1日

研究注册日期

首次提交

2016年8月19日

首先提交符合 QC 标准的

2016年8月25日

首次发布 (估计)

2016年8月26日

研究记录更新

最后更新发布 (估计)

2016年8月26日

上次提交的符合 QC 标准的更新

2016年8月25日

最后验证

2016年8月1日

更多信息

与本研究相关的术语

其他研究编号

  • NantongU_001

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

在美国制造并从美国出口的产品

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

3