High-intensity Laser Therapy Versus Extracorporeal Shock Wave on Tendon Thickness and Occupation Ratio In Patients With Chronic Supraspinatus Tendinopathy (HILT)
19. června 2026 aktualizováno: Mahmoud Mamdouh Ahmed Shaaban, Cairo University
This study will be conducted to investigate the difference between high-intensity laser and extracorporeal shock wave on supraspinatus tendon thickness, subacromial space, occupation ratio, shoulder pain intensity, shoulder range of motion (ROM), hand strength, and functional disability in patients with chronic supraspinatus tendinopathy.
Přehled studie
Postavení
Zatím nenabíráme
Podmínky
Detailní popis
Supraspinatus tendinopathy is a common cause of shoulder pain and dysfunction due to irritation, inflammation, or degeneration of the supraspinatus tendon in the rotator cuff.
It is caused by repetitive overhead movements and is characterized by pain, weakness, and a limited range of motion, especially when reaching or lifting the arm.
Recently, studies have demonstrated that HILT is useful for treating a variety of shoulder impairments, including subacromial impingement syndrome, rotator cuff tendinopathy, and adhesive capsulitis.Shock wave is an effective and noninvasive method of reducing pain and increasing ROM and functional status without the need for surgery; it has been successfully utilized to treat tendinopathy over the past 20 years.There is a gap in available literature about comparing the high-intensity laser and extracorporeal shock wave in patients withchronic supraspinatus tendonitis.
So this study may add a piece of information to the physiotherapists in the government hospitals and the private clinics about showing the difference between the application of High Intensity laser and extracorporeal shock wave in patients with chronic supraspinatus tendinitis
Typ studie
Intervenční
Zápis (Odhadovaný)
69
Fáze
- Nelze použít
Kontakty a umístění
Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.
Studijní kontakt
- Jméno: mahmoud shaaban, phd
- Telefonní číslo: 01001080842
- E-mail: shaabab.m@outlook.com
Kritéria účasti
Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
Přijímá zdravé dobrovolníky
Ne
Popis
Inclusion Criteria:
- Patients from 18 to 50 years old of both genders.
- Unilateral Chronic Supraspinatus Tendinitis in dominant side
- BMI 18.5-24.9
- Tenderness is found over the supraspinatus as it passes subacromial and anterolateral The patient will report pain with active shoulder elevation in the scapular plane (eg: welders, plate workers, slaughterhouse workers and overhead playing athletes)
- The patient will report pain with resisted isometric abduction.
- The patient will report positive Jobe's test (empty can test)
Exclusion Criteria:
- Post shoulder surgery, traumatic incidents
- Partial tears at surgery
- Massive retracted tears at surgery
- Frozen shoulder Rotator cuff tear
- Glenohumeral or acromioclavicular arthritis
- Implanted pacemaker
- Pregnancy
Studijní plán
Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Singl
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: High-intensity Laser Therapy
Twenty-three patients with chronic supraspinatus tendinopathy will receive high-intensity laser and conventional physiotherapy twice a week for six weeks
|
the patients will receive HILT with peak power 3kW, intensity 15000W/cm and energy per pulse 350 mj) at supraspinatus tendenopathy.The treatment consisted of 3 phases in each session.
the initial phase will be rapid manual scanning (100 cm2/30s) of the anterior joint line of the shoulder with one shot of 850 mj at frequency of 30 Hz.
The scanning will be performed parallel to the joint line, with the patient arm internally rotated on the posterior scan and externally rotated on the anterior scan.
the intermediate phase will be a fixed scan phase , with one -shot emission of 350mj at a frequency of 20-25Hz.
plus conventional therapy
will receive Conventional physical therapy in form of stretching exercise of posterior shoulder capsule, passive stretching exercise, will be done only 3 times with holding time 30 sec and 10 sec rest period between repetitions , strengthing exercise consists of 3 exercises all have been recommended as essential for any shoulder rehabilitation program.
These exercise include shoulder flexion, scaption and horizontal extension.
for each exercise, a 10-repetition maximum for 3 sets with 60 sec rest between every set + TENS and hot back.
|
|
Experimentální: Extracorporeal Shock Wave
Twenty-three patients with chronic supraspinatus tendinopathy will receive extracorporeal shock wave and conventional physiotherapy twice a week for six weeks
|
will receive Conventional physical therapy in form of stretching exercise of posterior shoulder capsule, passive stretching exercise, will be done only 3 times with holding time 30 sec and 10 sec rest period between repetitions , strengthing exercise consists of 3 exercises all have been recommended as essential for any shoulder rehabilitation program.
These exercise include shoulder flexion, scaption and horizontal extension.
for each exercise, a 10-repetition maximum for 3 sets with 60 sec rest between every set + TENS and hot back.
patients will be sitting with shoulder abduction at 45 and elbow flexed and the forearm rested on flat surface and shock wave applicator directed in the most tender point near the insertion at the greater tubrosity under acromion with 2000 impulses, and energy flex density of 0.22mj/mm , pulse rate 10/sec and frequency 1-15 Hz plus conventional therapy
|
|
Aktivní komparátor: conventional therapy
Twenty-three patients with chronic supraspinatus tendinopathy will receive conventional physiotherapy twice a week for six weeks
|
will receive Conventional physical therapy in form of stretching exercise of posterior shoulder capsule, passive stretching exercise, will be done only 3 times with holding time 30 sec and 10 sec rest period between repetitions , strengthing exercise consists of 3 exercises all have been recommended as essential for any shoulder rehabilitation program.
These exercise include shoulder flexion, scaption and horizontal extension.
for each exercise, a 10-repetition maximum for 3 sets with 60 sec rest between every set + TENS and hot back.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
supraspinatous tendon thickness
Časové okno: up to 6 weeks
|
supraspinatus tendon thickness will be assess by ultrasonography.The tendon often appears swollen or thickened (frequently > 6 to 7 mm)
|
up to 6 weeks
|
|
supracromial space
Časové okno: up to 6 weeks
|
supracromial space will be measured by ultrasonography.
A normal resting subacromial space generally ranges from 9 to 11 mm.
A measurement of less than 6 mm is often pathological
|
up to 6 weeks
|
|
occupation ratio of subacromial space
Časové okno: up to 6 weeks
|
The ratio comparing the thickness of the supraspinatus tendon to the overall acromiohumeral distance.
An increased occupation ratio (i.e., a thickened tendon taking up too much of the space) indicates a higher risk of impingement
|
up to 6 weeks
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
pain intensity
Časové okno: up to 6 weeks
|
visuala analogue scale will be used to assess pain intesity.
it is a line of 100 mm.The ends are labeled with extremes, such as "No pain" at 0 mm and "Worst pain imaginable" at 100 mm.
|
up to 6 weeks
|
|
shoulder range of motion
Časové okno: up to six weeks
|
the range of motion will be measured by electrogoniometer
|
up to six weeks
|
|
upper limb disability
Časové okno: up to six weeks
|
The QuickDASH will be used to assess upper limb function.the
QuickDASH is an 11-item questionnaire used to measure physical function and symptoms in people with upper limb disorders.
Scores range from 0 (no disability) to 100 (most severe disability).
|
up to six weeks
|
|
supraspinatus muscle strength
Časové okno: up to six weeks
|
supraspinatus muscle strength will be measured by handheld dynamometer
|
up to six weeks
|
Spolupracovníci a vyšetřovatelé
Zde najdete lidi a organizace zapojené do této studie.
Sponzor
Termíny studijních záznamů
Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.
Hlavní termíny studia
Začátek studia (Odhadovaný)
30. června 2026
Primární dokončení (Odhadovaný)
25. dubna 2027
Dokončení studie (Odhadovaný)
25. dubna 2027
Termíny zápisu do studia
První předloženo
19. června 2026
První předloženo, které splnilo kritéria kontroly kvality
19. června 2026
První zveřejněno (Aktuální)
25. června 2026
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
25. června 2026
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
19. června 2026
Naposledy ověřeno
1. června 2026
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- P.T.REC/012/006491
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Ne
Studuje produkt zařízení regulovaný americkým úřadem FDA
Ne
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .