Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Coronary Access After Evolut FX Plus TAVI: Impact of Commissural Alignment and the Large-Cell Frame Design: ACCESS-FX+ Registry

7. září 2026 aktualizováno: Yonsei University

The ACCESS-FX+ Registry is a prospective, multicenter, single-arm study designed to evaluate the feasibility of coronary access after transcatheter aortic valve implantation (TAVI) using the Evolut FX Plus transcatheter heart valve in patients with severe aortic stenosis.

TAVI has become an established treatment for patients with severe aortic stenosis across a broad range of surgical risk profiles. As TAVI is increasingly performed in younger patients with longer life expectancy, maintaining access to the coronary arteries after transcatheter heart valve implantation has become an important clinical consideration. A substantial proportion of patients undergoing TAVI have concomitant coronary artery disease and may subsequently require coronary angiography or percutaneous coronary intervention. However, coronary access after TAVI may be challenging because of the spatial relationship between the transcatheter heart valve frame, commissural posts, valve leaflets, and coronary ostia.

Commissural alignment between the native aortic valve and the implanted transcatheter heart valve may play an important role in preserving coronary access. Commissural misalignment may result in a commissural post or valve leaflet being positioned in front of a coronary ostium, potentially interfering with subsequent selective coronary cannulation. In addition to commissural alignment, the geometry and orientation of the transcatheter valve frame relative to the coronary ostia may influence the feasibility of coronary re-access.

The Evolut FX Plus transcatheter heart valve incorporates three enlarged frame cells designed to facilitate coronary access. This modification is intended to increase the likelihood that at least one large cell is favorably positioned relative to each coronary ostium. However, prospective data evaluating selective coronary cannulation through these large cells and the relationship between large-cell orientation, commissural alignment, and coronary anatomy in clinical practice remain limited.

The study will enroll approximately 122 patients aged 65 years or older with severe aortic stenosis undergoing TAVI with the Evolut FX Plus valve. Immediately after valve implantation, selective cannulation of the left and right coronary arteries through the large-cell frame will be attempted using standard diagnostic coronary catheters. The primary endpoint is the successful selective coronary cannulation rate through the Evolut FX Plus large-cell frame, assessed separately for the left and right coronary arteries. Successful selective coronary cannulation is defined as stable engagement of a diagnostic catheter at the coronary ostium allowing coronary contrast injection.

Cardiac computed tomography (CT) performed 3 to 6 months after TAVI will provide a detailed assessment of the spatial relationship between the implanted transcatheter heart valve and the coronary ostia. CT-based assessments will include large cell-to-coronary alignment, alignment between the center of the transcatheter valve leaflet and the coronary ostium, and commissural alignment between the native and transcatheter aortic valves. Follow-up CT will also be used to evaluate findings of valve thrombosis, including leaflet, supravalvular, subvalvular, and sinus hypoattenuation.

Přehled studie

Postavení

Zatím nenabíráme

Detailní popis

TAVI will be performed according to standard clinical practice. A commissural alignment technique will be used during valve implantation, with appropriate orientation of the delivery system and fluoroscopic assessment during valve deployment.

Immediately after valve implantation, selective coronary cannulation of the left coronary artery and right coronary artery through the Evolut FX Plus large-cell frame will be attempted using standard diagnostic coronary catheters. The primary endpoint is the successful selective coronary cannulation rate through the large-cell frame, assessed separately for the left and right coronary arteries. Successful selective coronary cannulation is defined as stable engagement of the diagnostic catheter at the coronary ostium allowing coronary contrast injection.

Cardiac CT performed 3 to 6 months after TAVI will be analyzed to assess the spatial relationship between the implanted valve and the coronary ostia. CT-based assessments will include large cell-to-coronary alignment, alignment between the center of the transcatheter valve leaflet and the coronary ostium, commissural alignment between the native and transcatheter aortic valves, and findings of valve thrombosis, including leaflet, supravalvular, subvalvular, and sinus hypoattenuation.

Clinical efficacy and safety outcomes will be assessed at 30 days and 6 months. Clinical events will be defined according to Valve Academic Research Consortium-3 (VARC-3) criteria where applicable.

Typ studie

Pozorovací

Zápis (Odhadovaný)

122

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

  • Jméno: Young-Guk Ko, Professor
  • Telefonní číslo: +82-2-2228-8460
  • E-mail: ygko@yuhs.ac

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Starší dospělý

Přijímá zdravé dobrovolníky

Ne

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.

Popis

Inclusion Criteria:

  1. Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.
  2. Age ≥65 years.
  3. Ability and willingness to provide written informed consent for participation in the study.

Exclusion Criteria:

  1. Inability to undergo contrast-enhanced cardiac CT before TAVI.
  2. Anomalous origin of a coronary artery.
  3. Bicuspid aortic valve.
  4. Previous surgical or transcatheter aortic valve replacement.
  5. Cardiogenic shock or hemodynamic instability.
  6. Chronic kidney disease stage 3b, 4, or 5, defined as estimated glomerular filtration rate (eGFR) <45 mL/min/1.73 m².
  7. Thrombocytopenia (platelet count <100,000/μL) or an increased bleeding risk precluding antiplatelet or anticoagulant therapy.
  8. Allergy or hypersensitivity to aspirin or clopidogrel precluding antiplatelet therapy in patients without an indication for oral anticoagulation.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Kohorty a intervence

Skupina / kohorta
Patients undergoing TAVI using Evolut FX Plus
Patients aged 65 years or older with severe aortic stenosis who are scheduled to undergo TAVI with the Evolut FX Plus transcatheter heart valve and who meet all eligibility criteria.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Successful Selective Coronary Cannulation Through the Evolut FX Plus Large-Cell Frame
Časové okno: Day 0 (Immediately after Evolut FX Plus implantation)
The proportion of patients in whom successful selective coronary cannulation is achieved through the Evolut FX Plus large-cell frame, assessed separately for the left coronary artery and right coronary artery. Successful selective coronary cannulation is defined as stable engagement of a standard diagnostic catheter at the coronary ostium allowing coronary contrast injection.
Day 0 (Immediately after Evolut FX Plus implantation)

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Technical Success
Časové okno: 30 days after TAVI
Technical success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
30 days after TAVI
Devicel Success
Časové okno: 30 days after TAVI
Device success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
30 days after TAVI
Clinical outcomes (Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization)
Časové okno: 6 months after TAVI
Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization
6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Large Cell-to-Coronary Misalignment)
Časové okno: 3 to 6 months after TAVI
1) Moderate or Greater Large Cell-to-Coronary Misalignment:: Proportion of patients with moderate or severe large cell-to-coronary misalignment on follow-up cardiac CT. Alignment is determined by the angle between the center of the large cell and the center of the coronary ostium.
3 to 6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Leaflet Center-to-Coronary Misalignment)
Časové okno: 3 to 6 months after TAVI
  1. Moderate or Greater Leaflet Center-to-Coronary Misalignment:

    Proportion of patients with moderate or severe misalignment between the center axis of the transcatheter valve leaflet and the center of the coronary ostium on follow-up cardiac CT.

  2. Moderate or Greater Commissural Misalignment
3 to 6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Commissural Misalignment)
Časové okno: 3 to 6 months after TAVI

Moderate or Greater Commissural Misalignment::

Proportion of patients with moderate or severe commissural misalignment between the native aortic valve commissures and the transcatheter heart valve commissures on follow-up cardiac CT.

3 to 6 months after TAVI

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Odhadovaný)

29. září 2026

Primární dokončení (Odhadovaný)

30. září 2028

Dokončení studie (Odhadovaný)

31. března 2029

Termíny zápisu do studia

První předloženo

31. srpna 2026

První předloženo, které splnilo kritéria kontroly kvality

7. září 2026

První zveřejněno (Aktuální)

10. září 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

10. září 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

7. září 2026

Naposledy ověřeno

1. září 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit