Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Coronary Access After Evolut FX Plus TAVI: Impact of Commissural Alignment and the Large-Cell Frame Design: ACCESS-FX+ Registry

7 september 2026 uppdaterad av: Yonsei University

The ACCESS-FX+ Registry is a prospective, multicenter, single-arm study designed to evaluate the feasibility of coronary access after transcatheter aortic valve implantation (TAVI) using the Evolut FX Plus transcatheter heart valve in patients with severe aortic stenosis.

TAVI has become an established treatment for patients with severe aortic stenosis across a broad range of surgical risk profiles. As TAVI is increasingly performed in younger patients with longer life expectancy, maintaining access to the coronary arteries after transcatheter heart valve implantation has become an important clinical consideration. A substantial proportion of patients undergoing TAVI have concomitant coronary artery disease and may subsequently require coronary angiography or percutaneous coronary intervention. However, coronary access after TAVI may be challenging because of the spatial relationship between the transcatheter heart valve frame, commissural posts, valve leaflets, and coronary ostia.

Commissural alignment between the native aortic valve and the implanted transcatheter heart valve may play an important role in preserving coronary access. Commissural misalignment may result in a commissural post or valve leaflet being positioned in front of a coronary ostium, potentially interfering with subsequent selective coronary cannulation. In addition to commissural alignment, the geometry and orientation of the transcatheter valve frame relative to the coronary ostia may influence the feasibility of coronary re-access.

The Evolut FX Plus transcatheter heart valve incorporates three enlarged frame cells designed to facilitate coronary access. This modification is intended to increase the likelihood that at least one large cell is favorably positioned relative to each coronary ostium. However, prospective data evaluating selective coronary cannulation through these large cells and the relationship between large-cell orientation, commissural alignment, and coronary anatomy in clinical practice remain limited.

The study will enroll approximately 122 patients aged 65 years or older with severe aortic stenosis undergoing TAVI with the Evolut FX Plus valve. Immediately after valve implantation, selective cannulation of the left and right coronary arteries through the large-cell frame will be attempted using standard diagnostic coronary catheters. The primary endpoint is the successful selective coronary cannulation rate through the Evolut FX Plus large-cell frame, assessed separately for the left and right coronary arteries. Successful selective coronary cannulation is defined as stable engagement of a diagnostic catheter at the coronary ostium allowing coronary contrast injection.

Cardiac computed tomography (CT) performed 3 to 6 months after TAVI will provide a detailed assessment of the spatial relationship between the implanted transcatheter heart valve and the coronary ostia. CT-based assessments will include large cell-to-coronary alignment, alignment between the center of the transcatheter valve leaflet and the coronary ostium, and commissural alignment between the native and transcatheter aortic valves. Follow-up CT will also be used to evaluate findings of valve thrombosis, including leaflet, supravalvular, subvalvular, and sinus hypoattenuation.

Studieöversikt

Status

Har inte rekryterat ännu

Betingelser

Detaljerad beskrivning

TAVI will be performed according to standard clinical practice. A commissural alignment technique will be used during valve implantation, with appropriate orientation of the delivery system and fluoroscopic assessment during valve deployment.

Immediately after valve implantation, selective coronary cannulation of the left coronary artery and right coronary artery through the Evolut FX Plus large-cell frame will be attempted using standard diagnostic coronary catheters. The primary endpoint is the successful selective coronary cannulation rate through the large-cell frame, assessed separately for the left and right coronary arteries. Successful selective coronary cannulation is defined as stable engagement of the diagnostic catheter at the coronary ostium allowing coronary contrast injection.

Cardiac CT performed 3 to 6 months after TAVI will be analyzed to assess the spatial relationship between the implanted valve and the coronary ostia. CT-based assessments will include large cell-to-coronary alignment, alignment between the center of the transcatheter valve leaflet and the coronary ostium, commissural alignment between the native and transcatheter aortic valves, and findings of valve thrombosis, including leaflet, supravalvular, subvalvular, and sinus hypoattenuation.

Clinical efficacy and safety outcomes will be assessed at 30 days and 6 months. Clinical events will be defined according to Valve Academic Research Consortium-3 (VARC-3) criteria where applicable.

Studietyp

Observationell

Inskrivning (Beräknad)

122

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

  • Namn: Young-Guk Ko, Professor
  • Telefonnummer: +82-2-2228-8460
  • E-post: ygko@yuhs.ac

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Äldre vuxen

Tar emot friska volontärer

Nej

Testmetod

Icke-sannolikhetsprov

Studera befolkning

Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.

Beskrivning

Inclusion Criteria:

  1. Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.
  2. Age ≥65 years.
  3. Ability and willingness to provide written informed consent for participation in the study.

Exclusion Criteria:

  1. Inability to undergo contrast-enhanced cardiac CT before TAVI.
  2. Anomalous origin of a coronary artery.
  3. Bicuspid aortic valve.
  4. Previous surgical or transcatheter aortic valve replacement.
  5. Cardiogenic shock or hemodynamic instability.
  6. Chronic kidney disease stage 3b, 4, or 5, defined as estimated glomerular filtration rate (eGFR) <45 mL/min/1.73 m².
  7. Thrombocytopenia (platelet count <100,000/μL) or an increased bleeding risk precluding antiplatelet or anticoagulant therapy.
  8. Allergy or hypersensitivity to aspirin or clopidogrel precluding antiplatelet therapy in patients without an indication for oral anticoagulation.

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Kohorter och interventioner

Grupp / Kohort
Patients undergoing TAVI using Evolut FX Plus
Patients aged 65 years or older with severe aortic stenosis who are scheduled to undergo TAVI with the Evolut FX Plus transcatheter heart valve and who meet all eligibility criteria.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Successful Selective Coronary Cannulation Through the Evolut FX Plus Large-Cell Frame
Tidsram: Day 0 (Immediately after Evolut FX Plus implantation)
The proportion of patients in whom successful selective coronary cannulation is achieved through the Evolut FX Plus large-cell frame, assessed separately for the left coronary artery and right coronary artery. Successful selective coronary cannulation is defined as stable engagement of a standard diagnostic catheter at the coronary ostium allowing coronary contrast injection.
Day 0 (Immediately after Evolut FX Plus implantation)

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Technical Success
Tidsram: 30 days after TAVI
Technical success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
30 days after TAVI
Devicel Success
Tidsram: 30 days after TAVI
Device success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
30 days after TAVI
Clinical outcomes (Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization)
Tidsram: 6 months after TAVI
Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization
6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Large Cell-to-Coronary Misalignment)
Tidsram: 3 to 6 months after TAVI
1) Moderate or Greater Large Cell-to-Coronary Misalignment:: Proportion of patients with moderate or severe large cell-to-coronary misalignment on follow-up cardiac CT. Alignment is determined by the angle between the center of the large cell and the center of the coronary ostium.
3 to 6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Leaflet Center-to-Coronary Misalignment)
Tidsram: 3 to 6 months after TAVI
  1. Moderate or Greater Leaflet Center-to-Coronary Misalignment:

    Proportion of patients with moderate or severe misalignment between the center axis of the transcatheter valve leaflet and the center of the coronary ostium on follow-up cardiac CT.

  2. Moderate or Greater Commissural Misalignment
3 to 6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Commissural Misalignment)
Tidsram: 3 to 6 months after TAVI

Moderate or Greater Commissural Misalignment::

Proportion of patients with moderate or severe commissural misalignment between the native aortic valve commissures and the transcatheter heart valve commissures on follow-up cardiac CT.

3 to 6 months after TAVI

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

29 september 2026

Primärt slutförande (Beräknad)

30 september 2028

Avslutad studie (Beräknad)

31 mars 2029

Studieregistreringsdatum

Först inskickad

31 augusti 2026

Först inskickad som uppfyllde QC-kriterierna

7 september 2026

Första postat (Faktisk)

10 september 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

10 september 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

7 september 2026

Senast verifierad

1 september 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera