Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Coronary Access After Evolut FX Plus TAVI: Impact of Commissural Alignment and the Large-Cell Frame Design: ACCESS-FX+ Registry

7 de setembro de 2026 atualizado por: Yonsei University

The ACCESS-FX+ Registry is a prospective, multicenter, single-arm study designed to evaluate the feasibility of coronary access after transcatheter aortic valve implantation (TAVI) using the Evolut FX Plus transcatheter heart valve in patients with severe aortic stenosis.

TAVI has become an established treatment for patients with severe aortic stenosis across a broad range of surgical risk profiles. As TAVI is increasingly performed in younger patients with longer life expectancy, maintaining access to the coronary arteries after transcatheter heart valve implantation has become an important clinical consideration. A substantial proportion of patients undergoing TAVI have concomitant coronary artery disease and may subsequently require coronary angiography or percutaneous coronary intervention. However, coronary access after TAVI may be challenging because of the spatial relationship between the transcatheter heart valve frame, commissural posts, valve leaflets, and coronary ostia.

Commissural alignment between the native aortic valve and the implanted transcatheter heart valve may play an important role in preserving coronary access. Commissural misalignment may result in a commissural post or valve leaflet being positioned in front of a coronary ostium, potentially interfering with subsequent selective coronary cannulation. In addition to commissural alignment, the geometry and orientation of the transcatheter valve frame relative to the coronary ostia may influence the feasibility of coronary re-access.

The Evolut FX Plus transcatheter heart valve incorporates three enlarged frame cells designed to facilitate coronary access. This modification is intended to increase the likelihood that at least one large cell is favorably positioned relative to each coronary ostium. However, prospective data evaluating selective coronary cannulation through these large cells and the relationship between large-cell orientation, commissural alignment, and coronary anatomy in clinical practice remain limited.

The study will enroll approximately 122 patients aged 65 years or older with severe aortic stenosis undergoing TAVI with the Evolut FX Plus valve. Immediately after valve implantation, selective cannulation of the left and right coronary arteries through the large-cell frame will be attempted using standard diagnostic coronary catheters. The primary endpoint is the successful selective coronary cannulation rate through the Evolut FX Plus large-cell frame, assessed separately for the left and right coronary arteries. Successful selective coronary cannulation is defined as stable engagement of a diagnostic catheter at the coronary ostium allowing coronary contrast injection.

Cardiac computed tomography (CT) performed 3 to 6 months after TAVI will provide a detailed assessment of the spatial relationship between the implanted transcatheter heart valve and the coronary ostia. CT-based assessments will include large cell-to-coronary alignment, alignment between the center of the transcatheter valve leaflet and the coronary ostium, and commissural alignment between the native and transcatheter aortic valves. Follow-up CT will also be used to evaluate findings of valve thrombosis, including leaflet, supravalvular, subvalvular, and sinus hypoattenuation.

Visão geral do estudo

Status

Ainda não está recrutando

Descrição detalhada

TAVI will be performed according to standard clinical practice. A commissural alignment technique will be used during valve implantation, with appropriate orientation of the delivery system and fluoroscopic assessment during valve deployment.

Immediately after valve implantation, selective coronary cannulation of the left coronary artery and right coronary artery through the Evolut FX Plus large-cell frame will be attempted using standard diagnostic coronary catheters. The primary endpoint is the successful selective coronary cannulation rate through the large-cell frame, assessed separately for the left and right coronary arteries. Successful selective coronary cannulation is defined as stable engagement of the diagnostic catheter at the coronary ostium allowing coronary contrast injection.

Cardiac CT performed 3 to 6 months after TAVI will be analyzed to assess the spatial relationship between the implanted valve and the coronary ostia. CT-based assessments will include large cell-to-coronary alignment, alignment between the center of the transcatheter valve leaflet and the coronary ostium, commissural alignment between the native and transcatheter aortic valves, and findings of valve thrombosis, including leaflet, supravalvular, subvalvular, and sinus hypoattenuation.

Clinical efficacy and safety outcomes will be assessed at 30 days and 6 months. Clinical events will be defined according to Valve Academic Research Consortium-3 (VARC-3) criteria where applicable.

Tipo de estudo

Observacional

Inscrição (Estimado)

122

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

  • Nome: Young-Guk Ko, Professor
  • Número de telefone: +82-2-2228-8460
  • E-mail: ygko@yuhs.ac

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Método de amostragem

Amostra Não Probabilística

População do estudo

Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.

Descrição

Inclusion Criteria:

  1. Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.
  2. Age ≥65 years.
  3. Ability and willingness to provide written informed consent for participation in the study.

Exclusion Criteria:

  1. Inability to undergo contrast-enhanced cardiac CT before TAVI.
  2. Anomalous origin of a coronary artery.
  3. Bicuspid aortic valve.
  4. Previous surgical or transcatheter aortic valve replacement.
  5. Cardiogenic shock or hemodynamic instability.
  6. Chronic kidney disease stage 3b, 4, or 5, defined as estimated glomerular filtration rate (eGFR) <45 mL/min/1.73 m².
  7. Thrombocytopenia (platelet count <100,000/μL) or an increased bleeding risk precluding antiplatelet or anticoagulant therapy.
  8. Allergy or hypersensitivity to aspirin or clopidogrel precluding antiplatelet therapy in patients without an indication for oral anticoagulation.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Patients undergoing TAVI using Evolut FX Plus
Patients aged 65 years or older with severe aortic stenosis who are scheduled to undergo TAVI with the Evolut FX Plus transcatheter heart valve and who meet all eligibility criteria.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Successful Selective Coronary Cannulation Through the Evolut FX Plus Large-Cell Frame
Prazo: Day 0 (Immediately after Evolut FX Plus implantation)
The proportion of patients in whom successful selective coronary cannulation is achieved through the Evolut FX Plus large-cell frame, assessed separately for the left coronary artery and right coronary artery. Successful selective coronary cannulation is defined as stable engagement of a standard diagnostic catheter at the coronary ostium allowing coronary contrast injection.
Day 0 (Immediately after Evolut FX Plus implantation)

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Technical Success
Prazo: 30 days after TAVI
Technical success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
30 days after TAVI
Devicel Success
Prazo: 30 days after TAVI
Device success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
30 days after TAVI
Clinical outcomes (Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization)
Prazo: 6 months after TAVI
Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization
6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Large Cell-to-Coronary Misalignment)
Prazo: 3 to 6 months after TAVI
1) Moderate or Greater Large Cell-to-Coronary Misalignment:: Proportion of patients with moderate or severe large cell-to-coronary misalignment on follow-up cardiac CT. Alignment is determined by the angle between the center of the large cell and the center of the coronary ostium.
3 to 6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Leaflet Center-to-Coronary Misalignment)
Prazo: 3 to 6 months after TAVI
  1. Moderate or Greater Leaflet Center-to-Coronary Misalignment:

    Proportion of patients with moderate or severe misalignment between the center axis of the transcatheter valve leaflet and the center of the coronary ostium on follow-up cardiac CT.

  2. Moderate or Greater Commissural Misalignment
3 to 6 months after TAVI
CT-based Secondary Outcome (Moderate or Greater Commissural Misalignment)
Prazo: 3 to 6 months after TAVI

Moderate or Greater Commissural Misalignment::

Proportion of patients with moderate or severe commissural misalignment between the native aortic valve commissures and the transcatheter heart valve commissures on follow-up cardiac CT.

3 to 6 months after TAVI

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

29 de setembro de 2026

Conclusão Primária (Estimado)

30 de setembro de 2028

Conclusão do estudo (Estimado)

31 de março de 2029

Datas de inscrição no estudo

Enviado pela primeira vez

31 de agosto de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

7 de setembro de 2026

Primeira postagem (Real)

10 de setembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

10 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

7 de setembro de 2026

Última verificação

1 de setembro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .