- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07858682
Accuracy of the Calibrated Framework for Intra Oral Full Arch Scan (A Cross-over Study)
Accuracy of the Calibrated Framework for Intraoral Full-Arch Scanning Compared With Conventional Splinted Open-Tray Impression in Edentulous Patients: A Crossover Clinical Trial
This crossover clinical trial aims to compare the accuracy of conventional splinted open-tray implant impressions with intraoral digital scanning using a calibrated framework in completely edentulous patients rehabilitated with full-arch implant-supported prostheses. Accurate transfer of implant positions is essential for achieving a passive fit of the prosthetic framework and minimizing biological and mechanical complications.
Twenty healthy completely edentulous patients requiring full-arch implant rehabilitation will be enrolled. Each participant will undergo both conventional and digital impression techniques following implant placement, allowing direct within-subject comparison. The conventional technique consists of a verified splinted open-tray impression, while the digital technique uses an intraoral scanner in combination with a calibrated stock framework.
The accuracy of the two impression techniques will be evaluated by superimposing the resulting STL files using Geomagic Control X software. Linear deviations in the x-, y-, and z-axes, angular deviations, and global deviations will be measured and compared. The findings of this study are expected to provide clinical evidence regarding the accuracy of calibrated framework-assisted intraoral scanning compared with the conventional impression technique for full-arch implant rehabilitation.
Přehled studie
Postavení
Podmínky
Detailní popis
The passive fit of full-arch implant-supported prostheses is a critical factor influencing the long-term success of implant rehabilitation. Because dental implants lack a periodontal ligament, inaccuracies in transferring implant positions may result in framework misfit, leading to biological and mechanical complications such as screw loosening, component fracture, or implant failure. Conventional splinted open-tray impressions are considered the reference standard for full-arch implant impressions; however, they are technique-sensitive, time-consuming, and susceptible to material distortion and operator-related errors.
Advances in digital dentistry have enabled the use of intraoral scanners for implant impressions. Nevertheless, complete-arch digital scanning remains challenging because cumulative stitching errors may reduce scanning accuracy. The use of a calibrated framework has recently been proposed to improve the accuracy of complete-arch intraoral scanning by providing stable geometric reference points during image acquisition. Although promising, clinical evidence comparing this technique with the conventional splinted open-tray impression technique remains limited.
The purpose of this crossover clinical trial is to compare the accuracy of conventional splinted open-tray impressions and intraoral digital scanning using a calibrated framework in completely edentulous patients receiving full-arch implant rehabilitation.
Twenty healthy completely edentulous patients will be recruited. Following implant placement, each participant will undergo both impression techniques. The conventional workflow will consist of a verified splinted open-tray implant impression, while the digital workflow will involve intraoral scanning using a calibrated stock framework attached to implant scan bodies. STL datasets obtained from both techniques will be analyzed using Geomagic Control X software. The digital models will be superimposed to assess linear deviations along the x-, y-, and z-axes, angular deviations, and global three-dimensional deviations. The results will be statistically analyzed to determine whether the calibrated framework-assisted digital workflow provides transfer accuracy comparable to or greater than the conventional impression technique.
Typ studie
Zápis (Odhadovaný)
Fáze
- Nelze použít
Kontakty a umístění
Studijní kontakt
- Jméno: noor alhuda raheem, BDS
- Telefonní číslo: 01044487126
- E-mail: nooralkhalil95@yahoo.com
Studijní místa
-
-
-
Al Mansurah, Egypt, 12345
- Nábor
- Noor Alhuda Rahemm Khalil
-
Kontakt:
- osama asker, PHD
- Telefonní číslo: 01010848407
- E-mail: osamaasker@gmail.com
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Adults aged 18 years or older.
- Completely edentulous maxilla and mandible for at least 6 months following the last tooth extraction.
- Angle's Class I maxillomandibular relationship with adequate interarch space.
- Sufficient residual alveolar bone quantity and quality to receive dental implants.
- Good oral hygiene.
- Free from uncontrolled systemic diseases or conditions that may interfere with implant osseointegration.
- Able and willing to provide written informed consent.
Exclusion Criteria:
- Temporomandibular joint disorders or parafunctional habits.
- Heavy smokers.
- Uncontrolled systemic diseases.
- History of chemotherapy or radiotherapy to the head and neck region.
- Poor neuromuscular coordination.
- Localized bone defects that could compromise implant placement.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: Nerandomizované
- Intervenční model: Crossover Assignment
- Maskování: Singl
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Aktivní komparátor: Conventional Splinted Open-Tray Impression
Participants will undergo a conventional verified splinted open-tray implant impression following implant placement. Impression copings will be splinted using dental floss and autopolymerizing resin, and a polyvinyl siloxane (PVS) impression will be made. The resulting master cast will be digitized using a laboratory scanner to generate an STL file for accuracy assessment. |
A conventional verified splinted open-tray implant impression will be performed after implant placement. Multi-unit impression copings will be splinted using dental floss and autopolymerizing resin, followed by a polyvinyl siloxane (PVS) impression. The master cast will be fabricated, verified, and scanned with a laboratory scanner to generate an STL file for accuracy analysis.
Ostatní jména:
|
|
Experimentální: Intraoral Digital Scanning with Calibrated Framework
Participants will undergo intraoral digital scanning using an intraoral scanner and a calibrated stock framework attached to implant scan bodies after implant placement. The generated STL file will be compared with the conventional impression using Geomagic Control X software to evaluate transfer accuracy. |
An intraoral digital impression will be obtained after implant placement using an intraoral scanner and a calibrated stock framework attached to implant scan bodies. The resulting STL dataset will be compared with the conventional impression using Geomagic Control X software to evaluate linear, angular, and global deviations in implant position transfer accuracy.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Implant Position Transfer Accuracy (Linear deviations)
Časové okno: Immediately after impression procedures following implant placement (same study visit).
|
by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software. Linear deviations (x-, y-, and z-axes) |
Immediately after impression procedures following implant placement (same study visit).
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Implant Position Transfer Accuracy (Angular deviations)
Časové okno: Immediately after impression procedures following implant placement (same study visit).
|
Accuracy of implant position transfer will be assessed by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software |
Immediately after impression procedures following implant placement (same study visit).
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Studijní židle: osama asker, PHD, Mansoura University
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
- MS.26.01.135
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
upon request from the corresponding author
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .