Accuracy of the Calibrated Framework for Intra Oral Full Arch Scan (A Cross-over Study)

30. september 2026 opdateret af: Noor Elhoda Alkhalil, Mansoura University

Accuracy of the Calibrated Framework for Intraoral Full-Arch Scanning Compared With Conventional Splinted Open-Tray Impression in Edentulous Patients: A Crossover Clinical Trial

This crossover clinical trial aims to compare the accuracy of conventional splinted open-tray implant impressions with intraoral digital scanning using a calibrated framework in completely edentulous patients rehabilitated with full-arch implant-supported prostheses. Accurate transfer of implant positions is essential for achieving a passive fit of the prosthetic framework and minimizing biological and mechanical complications.

Twenty healthy completely edentulous patients requiring full-arch implant rehabilitation will be enrolled. Each participant will undergo both conventional and digital impression techniques following implant placement, allowing direct within-subject comparison. The conventional technique consists of a verified splinted open-tray impression, while the digital technique uses an intraoral scanner in combination with a calibrated stock framework.

The accuracy of the two impression techniques will be evaluated by superimposing the resulting STL files using Geomagic Control X software. Linear deviations in the x-, y-, and z-axes, angular deviations, and global deviations will be measured and compared. The findings of this study are expected to provide clinical evidence regarding the accuracy of calibrated framework-assisted intraoral scanning compared with the conventional impression technique for full-arch implant rehabilitation.

Studieoversigt

Detaljeret beskrivelse

The passive fit of full-arch implant-supported prostheses is a critical factor influencing the long-term success of implant rehabilitation. Because dental implants lack a periodontal ligament, inaccuracies in transferring implant positions may result in framework misfit, leading to biological and mechanical complications such as screw loosening, component fracture, or implant failure. Conventional splinted open-tray impressions are considered the reference standard for full-arch implant impressions; however, they are technique-sensitive, time-consuming, and susceptible to material distortion and operator-related errors.

Advances in digital dentistry have enabled the use of intraoral scanners for implant impressions. Nevertheless, complete-arch digital scanning remains challenging because cumulative stitching errors may reduce scanning accuracy. The use of a calibrated framework has recently been proposed to improve the accuracy of complete-arch intraoral scanning by providing stable geometric reference points during image acquisition. Although promising, clinical evidence comparing this technique with the conventional splinted open-tray impression technique remains limited.

The purpose of this crossover clinical trial is to compare the accuracy of conventional splinted open-tray impressions and intraoral digital scanning using a calibrated framework in completely edentulous patients receiving full-arch implant rehabilitation.

Twenty healthy completely edentulous patients will be recruited. Following implant placement, each participant will undergo both impression techniques. The conventional workflow will consist of a verified splinted open-tray implant impression, while the digital workflow will involve intraoral scanning using a calibrated stock framework attached to implant scan bodies. STL datasets obtained from both techniques will be analyzed using Geomagic Control X software. The digital models will be superimposed to assess linear deviations along the x-, y-, and z-axes, angular deviations, and global three-dimensional deviations. The results will be statistically analyzed to determine whether the calibrated framework-assisted digital workflow provides transfer accuracy comparable to or greater than the conventional impression technique.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

20

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

Studiesteder

      • Al Mansurah, Egypten, 12345
        • Rekruttering
        • Noor Alhuda Rahemm Khalil
        • Kontakt:

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

35 år til 60 år (Voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Completely edentulous maxilla and mandible for at least 6 months following the last tooth extraction.
  • Angle's Class I maxillomandibular relationship with adequate interarch space.
  • Sufficient residual alveolar bone quantity and quality to receive dental implants.
  • Good oral hygiene.
  • Free from uncontrolled systemic diseases or conditions that may interfere with implant osseointegration.
  • Able and willing to provide written informed consent.

Exclusion Criteria:

  • Temporomandibular joint disorders or parafunctional habits.
  • Heavy smokers.
  • Uncontrolled systemic diseases.
  • History of chemotherapy or radiotherapy to the head and neck region.
  • Poor neuromuscular coordination.
  • Localized bone defects that could compromise implant placement.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: Ikke-randomiseret
  • Interventionel model: Crossover opgave
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Conventional Splinted Open-Tray Impression

Participants will undergo a conventional verified splinted open-tray implant impression following implant placement. Impression copings will be splinted using dental floss and autopolymerizing resin, and a polyvinyl siloxane (PVS) impression will be made. The resulting master cast will be digitized using a laboratory scanner to generate an STL file for accuracy assessment.

A conventional verified splinted open-tray implant impression will be performed after implant placement. Multi-unit impression copings will be splinted using dental floss and autopolymerizing resin, followed by a polyvinyl siloxane (PVS) impression. The master cast will be fabricated, verified, and scanned with a laboratory scanner to generate an STL file for accuracy analysis.

Andre navne:
  • Conventional Implant Impression Open-Tray Impression Splinted Open-Tray Technique
Eksperimentel: Intraoral Digital Scanning with Calibrated Framework

Participants will undergo intraoral digital scanning using an intraoral scanner and a calibrated stock framework attached to implant scan bodies after implant placement. The generated STL file will be compared with the conventional impression using Geomagic Control X software to evaluate transfer accuracy.

An intraoral digital impression will be obtained after implant placement using an intraoral scanner and a calibrated stock framework attached to implant scan bodies. The resulting STL dataset will be compared with the conventional impression using Geomagic Control X software to evaluate linear, angular, and global deviations in implant position transfer accuracy.

Andre navne:
  • Calibrated Framework Technique Intraoral Digital Impression Full-Arch Intraoral Scanning

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Implant Position Transfer Accuracy (Linear deviations)
Tidsramme: Immediately after impression procedures following implant placement (same study visit).

by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software. Linear deviations (x-, y-, and z-axes)

Immediately after impression procedures following implant placement (same study visit).

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Implant Position Transfer Accuracy (Angular deviations)
Tidsramme: Immediately after impression procedures following implant placement (same study visit).

Accuracy of implant position transfer will be assessed by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software

Immediately after impression procedures following implant placement (same study visit).

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Studiestol: osama asker, PHD, Mansoura University

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. januar 2026

Primær færdiggørelse (Anslået)

1. februar 2027

Studieafslutning (Anslået)

1. april 2027

Datoer for studieregistrering

Først indsendt

2. juli 2026

Først indsendt, der opfyldte QC-kriterier

30. september 2026

Først opslået (Faktiske)

5. oktober 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

5. oktober 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

30. september 2026

Sidst verificeret

1. september 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

IPD-planbeskrivelse

upon request from the corresponding author

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner