Accuracy of the Calibrated Framework for Intra Oral Full Arch Scan (A Cross-over Study)

30 september 2026 bijgewerkt door: Noor Elhoda Alkhalil, Mansoura University

Accuracy of the Calibrated Framework for Intraoral Full-Arch Scanning Compared With Conventional Splinted Open-Tray Impression in Edentulous Patients: A Crossover Clinical Trial

This crossover clinical trial aims to compare the accuracy of conventional splinted open-tray implant impressions with intraoral digital scanning using a calibrated framework in completely edentulous patients rehabilitated with full-arch implant-supported prostheses. Accurate transfer of implant positions is essential for achieving a passive fit of the prosthetic framework and minimizing biological and mechanical complications.

Twenty healthy completely edentulous patients requiring full-arch implant rehabilitation will be enrolled. Each participant will undergo both conventional and digital impression techniques following implant placement, allowing direct within-subject comparison. The conventional technique consists of a verified splinted open-tray impression, while the digital technique uses an intraoral scanner in combination with a calibrated stock framework.

The accuracy of the two impression techniques will be evaluated by superimposing the resulting STL files using Geomagic Control X software. Linear deviations in the x-, y-, and z-axes, angular deviations, and global deviations will be measured and compared. The findings of this study are expected to provide clinical evidence regarding the accuracy of calibrated framework-assisted intraoral scanning compared with the conventional impression technique for full-arch implant rehabilitation.

Studie Overzicht

Gedetailleerde beschrijving

The passive fit of full-arch implant-supported prostheses is a critical factor influencing the long-term success of implant rehabilitation. Because dental implants lack a periodontal ligament, inaccuracies in transferring implant positions may result in framework misfit, leading to biological and mechanical complications such as screw loosening, component fracture, or implant failure. Conventional splinted open-tray impressions are considered the reference standard for full-arch implant impressions; however, they are technique-sensitive, time-consuming, and susceptible to material distortion and operator-related errors.

Advances in digital dentistry have enabled the use of intraoral scanners for implant impressions. Nevertheless, complete-arch digital scanning remains challenging because cumulative stitching errors may reduce scanning accuracy. The use of a calibrated framework has recently been proposed to improve the accuracy of complete-arch intraoral scanning by providing stable geometric reference points during image acquisition. Although promising, clinical evidence comparing this technique with the conventional splinted open-tray impression technique remains limited.

The purpose of this crossover clinical trial is to compare the accuracy of conventional splinted open-tray impressions and intraoral digital scanning using a calibrated framework in completely edentulous patients receiving full-arch implant rehabilitation.

Twenty healthy completely edentulous patients will be recruited. Following implant placement, each participant will undergo both impression techniques. The conventional workflow will consist of a verified splinted open-tray implant impression, while the digital workflow will involve intraoral scanning using a calibrated stock framework attached to implant scan bodies. STL datasets obtained from both techniques will be analyzed using Geomagic Control X software. The digital models will be superimposed to assess linear deviations along the x-, y-, and z-axes, angular deviations, and global three-dimensional deviations. The results will be statistically analyzed to determine whether the calibrated framework-assisted digital workflow provides transfer accuracy comparable to or greater than the conventional impression technique.

Studietype

Ingrijpend

Inschrijving (Geschat)

20

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Locaties

      • Al Mansurah, Egypte, 12345
        • Werving
        • Noor Alhuda Rahemm Khalil
        • Contact:

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

35 jaar tot 60 jaar (Volwassen)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Completely edentulous maxilla and mandible for at least 6 months following the last tooth extraction.
  • Angle's Class I maxillomandibular relationship with adequate interarch space.
  • Sufficient residual alveolar bone quantity and quality to receive dental implants.
  • Good oral hygiene.
  • Free from uncontrolled systemic diseases or conditions that may interfere with implant osseointegration.
  • Able and willing to provide written informed consent.

Exclusion Criteria:

  • Temporomandibular joint disorders or parafunctional habits.
  • Heavy smokers.
  • Uncontrolled systemic diseases.
  • History of chemotherapy or radiotherapy to the head and neck region.
  • Poor neuromuscular coordination.
  • Localized bone defects that could compromise implant placement.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Diagnostisch
  • Toewijzing: Niet-gerandomiseerd
  • Interventioneel model: Crossover-opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: Conventional Splinted Open-Tray Impression

Participants will undergo a conventional verified splinted open-tray implant impression following implant placement. Impression copings will be splinted using dental floss and autopolymerizing resin, and a polyvinyl siloxane (PVS) impression will be made. The resulting master cast will be digitized using a laboratory scanner to generate an STL file for accuracy assessment.

A conventional verified splinted open-tray implant impression will be performed after implant placement. Multi-unit impression copings will be splinted using dental floss and autopolymerizing resin, followed by a polyvinyl siloxane (PVS) impression. The master cast will be fabricated, verified, and scanned with a laboratory scanner to generate an STL file for accuracy analysis.

Andere namen:
  • Conventional Implant Impression Open-Tray Impression Splinted Open-Tray Technique
Experimenteel: Intraoral Digital Scanning with Calibrated Framework

Participants will undergo intraoral digital scanning using an intraoral scanner and a calibrated stock framework attached to implant scan bodies after implant placement. The generated STL file will be compared with the conventional impression using Geomagic Control X software to evaluate transfer accuracy.

An intraoral digital impression will be obtained after implant placement using an intraoral scanner and a calibrated stock framework attached to implant scan bodies. The resulting STL dataset will be compared with the conventional impression using Geomagic Control X software to evaluate linear, angular, and global deviations in implant position transfer accuracy.

Andere namen:
  • Calibrated Framework Technique Intraoral Digital Impression Full-Arch Intraoral Scanning

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Implant Position Transfer Accuracy (Linear deviations)
Tijdsspanne: Immediately after impression procedures following implant placement (same study visit).

by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software. Linear deviations (x-, y-, and z-axes)

Immediately after impression procedures following implant placement (same study visit).

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Implant Position Transfer Accuracy (Angular deviations)
Tijdsspanne: Immediately after impression procedures following implant placement (same study visit).

Accuracy of implant position transfer will be assessed by superimposing STL files obtained from the conventional splinted open-tray impression and intraoral digital scanning using a calibrated framework with Geomagic Control X software

Immediately after impression procedures following implant placement (same study visit).

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie stoel: osama asker, PHD, Mansoura University

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 januari 2026

Primaire voltooiing (Geschat)

1 februari 2027

Studie voltooiing (Geschat)

1 april 2027

Studieregistratiedata

Eerst ingediend

2 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

30 september 2026

Eerst geplaatst (Werkelijk)

5 oktober 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

5 oktober 2026

Laatste update ingediend die voldeed aan QC-criteria

30 september 2026

Laatst geverifieerd

1 september 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Beschrijving IPD-plan

upon request from the corresponding author

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .