Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Four Way Crossover Closed Loop With Exercise Detection

16. august 2018 opdateret af: Jessica Castle, Oregon Health and Science University

A Randomized, Four-way, Cross-over Outpatient Study to Assess the Efficacy of a Dual-hormone Versus Insulin Alone Closed-loop System With Exercise Detection vs a Predictive Low Glucose Suspend System vs Current Care

Closed-loop systems are an emerging technology that automate hormone delivery. They are quickly paving the way to revolutionize the treatment of type 1 diabetes. Several categories have emerged: dual-hormone (insulin and glucagon) closed-loop systems and closed-loop systems with insulin only, one variety of which is the low glucose suspend safety feature now available from Medtronic (MiniMed 530G with Enlite). The study described within this protocol is designed to test the efficacy of a new closed-loop algorithm for managing blood glucose in people with type 1 diabetes before and after exercise. The new algorithm will have 3 modes: a single hormone insulin only mode, a dual-hormone insulin and glucagon mode and an insulin only mode with predictive low glucose suspend, all with an exercise detection algorithm. The purpose of this study is to determine whether a dual hormone AP with an exercise detection algorithm outperforms both single hormone AP and a low glucose suspend algorithm and sensor augmented pump therapy using the subject's own insulin pump.

Studieoversigt

Detaljeret beskrivelse

Subjects will undergo four approximately 84 hour studies. The first day of each study will be an approximately 12 hour inpatient visit to include activities of daily living and an exercise period with 2 days spent as an outpatient. The subject will come back to the research center on the fourth day to complete another approximately 12 hour inpatient visit to include activities of daily living and an exercise period followed by removal of all devices. In randomized order, subjects will have glucose controlled using the following systems: 1) dual-hormone closed-loop system, 2) insulin only closed-loop system, 3) predictive low glucose suspend system and 4) sensor augmented pump therapy with subject using their own insulin and insulin pump. Both of the closed-loop system algorithms have an exercise detection algorithm that uses inputs from a heart rate monitor and accelerometer, the Zephyrlife BioPatch. After exercise detection, insulin is turned off for the first 30 minutes, the total insulin infusion rate is adjusted by an exercise multiplier, and for the dual-hormone system, the target glucose for glucagon is increased along with the maximum dose of glucagon allowed. The predictive low glucose suspend system will utilize the patient's optimized basal rates, correction factor, and carb ratio. The patient will bolus for meals and hyperglycemia as usual under PLGS, but will have the additional safety net of the pump suspending insulin when it predicts a hypoglycemic event. The Dexcom CGM system and the Tandem t:slim pumps will be used for all three intervention visits.

Subjects will arrive at the CTRC at 7am at the start of intervention visits. Subjects will eat breakfast, lunch and dinner in the research center. Subjects will eat breakfast at 8:30am. After breakfast, subjects will complete activities of daily living (sitting on a chair, lying on a bed, washing dishes, sweeping the floor, etc.). Subjects will eat lunch at 12pm. Subjects will exercise for 45 minutes on a treadmill around 2pm. Subjects will eat dinner at 6pm and be discharged. The subject will then go home for Day 2 and Day 3 and return on Day 4 to complete another 12 hour inpatient visit with the schedule of activities identical to Day 1.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

25

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Oregon
      • Portland, Oregon, Forenede Stater, 97239
        • Oregon Health and Science University

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

21 år til 45 år (Voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Diagnosis of type 1 diabetes mellitus for at least 1 year.
  • Physically willing and able to perform 45 min of exercise (as determined by the investigator after reviewing the subjects activity level)
  • Current use of an insulin pump.
  • Lives with another person age 18 or older who will be present while subject exercises at home and that can attend the training on using the system with the subject.
  • Lives within 20 miles of OHSU.
  • A1C<10%
  • Willingness to follow all study procedures, including attending all clinic visits.
  • Willingness to sign informed consent and HIPAA documents.

Exclusion Criteria:

  • Female of childbearing potential who is pregnant or intending to become pregnant or breast-feeding, or is not using adequate contraceptive methods. Acceptable contraception includes birth control pill / patch / vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence.
  • Any cardiovascular disease, defined as a clinically significant EKG abnormality at the time of screening or any history of: stroke, heart failure, myocardial infarction, angina pectoris, or coronary arterial bypass graft or angioplasty. Diagnosis of 2nd or 3rd degree heart block or any non-physiological arrhythmia judged by the investigator to be exclusionary.
  • Renal insufficiency (GFR < 60 ml/min, using the MDRD equation as report by the OHSU laboratory).
  • Liver failure, cirrhosis, or any other liver disease that compromises liver function as determined by the investigator.
  • Hematocrit of less than or equal to 34%.
  • Hypertensive subjects with systolic blood pressure >= 160 mmHg or diastolic blood pressure >= 100 mmHg despite treatment or who have treatment-refractory hypertension (e.g. requiring four or more medications).
  • History of severe hypoglycemia during the past 12 months prior to screening visit or hypoglycemia unawareness as judged by the investigator. Subjects will complete a hypoglycemia awareness questionnaire. Subjects will be excluded for four or more R responses.
  • Adrenal insufficiency.
  • Any active infection.
  • Known or suspected abuse of alcohol, narcotics, or illicit drugs.
  • Seizure disorder.
  • Active foot ulceration.
  • Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication.
  • Major surgical operation within 30 days prior to screening.
  • Use of an investigational drug within 30 days prior to screening.
  • Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus).
  • Bleeding disorder, treatment with warfarin, or platelet count below 50,000.
  • Allergy to aspart insulin.
  • Allergy to glucagon.
  • Insulin resistance requiring more than 200 units per day.
  • Need for uninterrupted treatment of acetaminophen.
  • Current administration of oral or parenteral corticosteroids.
  • Any life threatening disease, including malignant neoplasms and medical history of malignant neoplasms within the past 5 years prior to screening (except basal and squamous cell skin cancer).
  • Beta blockers or non-dihydropyridine calcium channel blockers.
  • Current use of any medication intended to lower glucose other than insulin (ex. use of liraglutide).
  • Diagnosis of pheochromocytoma, insulinoma, or glucagonoma, personal or family history of multiple endocrine neoplasia (MEN) 2A, MEN 2B, neurofibromatosis or von Hippel-Lindau disease.
  • History of severe hypersensitivity to milk protein.
  • Current use of any medication with strong anticholinergic properties, such as antihistamines, sleep aids, and antidiarrheal medications.
  • Current use of indomethacin.
  • Conditions that may result in low levels of releasable glucose in the liver and an inadequate reversal of hypoglycemia by glucagon such as prolonged fasting, starvation or chronic hypoglycemia as determined by the investigator.
  • A positive response to any of the questions from the Physical Activity Readiness Questionnaire.
  • Any chest discomfort with physical activity, including pain or pressure, or other types of discomfort.
  • Any clinically significant disease or disorder which in the opinion of the Investigator may jeopardize the subject's safety or compliance with the protocol.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Crossover opgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Predictive Low Glucose Suspend Arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient. The predictive low glucose suspend system will run through the artificial pancreas controller in predictive low glucose suspend mode and utilize the patient's optimized basal rates, correction factor, and carb ratio, but it will have the additional safety net of the pump suspending insulin when it predicts a hypoglycemic event.
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to one Tandem t:slim insulin pumps filled with insulin.
Eksperimentel: Dual Hormone Closed-loop Arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient using the closed-loop artificial pancreas controller in dual hormone mode to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery and an increase in glucagon delivery upon detection.
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. Closed-loop Artificial Pancreas Controller includes insulin and glucagon delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to two Tandem t:slim insulin pumps, one filled with insulin and one with glucagon.
Andre navne:
  • APC
Eksperimentel: Single Hormone Closed-loop Arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient using the closed-loop artificial pancreas controller in single hormone mode to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery upon detection.
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component. The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend. Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to one Tandem t:slim insulin pumps filled with insulin.
Aktiv komparator: Sensor Augmented Pump Therapy arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient with subject's insulin pump and glucose sensor, if he/she typically uses one. Subjects will still wear a heart rate monitor uploading to a smart phone.
Subject will continue on their subcutaneous delivery of insulin on his/her own insulin pump using their own basal rates and carb ratios for meal boluses, managing their blood sugar as they normally would.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Percent of Time With Sensed Glucose < 3.9 mmol/L
Tidsramme: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.9 mmol/L using Dexcom sensor downloads across all four arms.
entire 84 hour study
Percent of Time With Sensed Glucose < 3.9 mmol/L
Tidsramme: From 14:00-18:00 for each 12 hour inpatient visit
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.9 mmol/L using Dexcom sensor downloads across all four arms.
From 14:00-18:00 for each 12 hour inpatient visit
Percent of Time With Sensed Glucose Between 3.9-10 mmol/L
Tidsramme: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values between 3.9-10 mmol/L using Dexcom sensor downloads across all four arms.
entire 84 hour study
Percent of Time With Sensed Glucose Between 3.9-10 mmol/L
Tidsramme: From 14:00-18:00 for each 12 hour inpatient visit
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values between 3.9-10 mmol/L using Dexcom sensor downloads across all four arms.
From 14:00-18:00 for each 12 hour inpatient visit

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Mean Sensed Glucose
Tidsramme: entire 84 hour study
Assess the mean sensor glucose using Dexcom sensor downloads across all four arms.
entire 84 hour study
Number of Carbohydrate Treatments
Tidsramme: entire 84 hour study
Assess the number of rescue carbohydrate treatments per day across all four arms.
entire 84 hour study
Percent of Time With Sensed Glucose < 3.0 mmol/L
Tidsramme: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.0 mmol/L using Dexcom sensor downloads across all four arms.
entire 84 hour study
Percent of Time With Sensed Glucose > 10 mmol/L
Tidsramme: entire 84 hour study
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values greater than 10 mmol/L using Dexcom sensor downloads across all four arms
entire 84 hour study
Number of Events With Capillary Blood Glucose < 3.9 mmol/L
Tidsramme: entire 84 hour study
Assess number of events with capillary blood glucose < 3.9 mmol/L using downloads from a Contour Next blood glucose meter across all four arms. .
entire 84 hour study
Number of Events With Capillary Blood Glucose < 3.0 mmol/L
Tidsramme: entire 84 hour study
Assess number of events with capillary blood glucose < 3.0 mmol/L using downloads from a Contour Next blood glucose meter across all four arms.
entire 84 hour study
Mean Amount of Insulin Delivered
Tidsramme: 24 hours
Assess the average amount of insulin delivered per day in units/kg as documented through the artificial pancreas controller across all four arms.
24 hours
Mean Amount of Glucagon Delivered
Tidsramme: 24 hours
Assess the average amount of insulin delivered per day in units/kg as documented through the artificial pancreas controller in dual hormone arm.
24 hours

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. oktober 2016

Primær færdiggørelse (Faktiske)

1. august 2017

Studieafslutning (Faktiske)

31. januar 2018

Datoer for studieregistrering

Først indsendt

28. juli 2016

Først indsendt, der opfyldte QC-kriterier

5. august 2016

Først opslået (Skøn)

11. august 2016

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

14. september 2018

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

16. august 2018

Sidst verificeret

1. august 2018

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Type 1 diabetes

Abonner