Subjects will undergo four approximately 84 hour studies. The first day of each study will be an approximately 12 hour inpatient visit to include activities of daily living and an exercise period with 2 days spent as an outpatient. The subject will come back to the research center on the fourth day to complete another approximately 12 hour inpatient visit to include activities of daily living and an exercise period followed by removal of all devices. In randomized order, subjects will have glucose controlled using the following systems: 1) dual-hormone closed-loop system, 2) insulin only closed-loop system, 3) predictive low glucose suspend system and 4) sensor augmented pump therapy with subject using their own insulin and insulin pump. Both of the closed-loop system algorithms have an exercise detection algorithm that uses inputs from a heart rate monitor and accelerometer, the Zephyrlife BioPatch. After exercise detection, insulin is turned off for the first 30 minutes, the total insulin infusion rate is adjusted by an exercise multiplier, and for the dual-hormone system, the target glucose for glucagon is increased along with the maximum dose of glucagon allowed. The predictive low glucose suspend system will utilize the patient's optimized basal rates, correction factor, and carb ratio. The patient will bolus for meals and hyperglycemia as usual under PLGS, but will have the additional safety net of the pump suspending insulin when it predicts a hypoglycemic event. The Dexcom CGM system and the Tandem t:slim pumps will be used for all three intervention visits.
Subjects will arrive at the CTRC at 7am at the start of intervention visits. Subjects will eat breakfast, lunch and dinner in the research center. Subjects will eat breakfast at 8:30am. After breakfast, subjects will complete activities of daily living (sitting on a chair, lying on a bed, washing dishes, sweeping the floor, etc.). Subjects will eat lunch at 12pm. Subjects will exercise for 45 minutes on a treadmill around 2pm. Subjects will eat dinner at 6pm and be discharged. The subject will then go home for Day 2 and Day 3 and return on Day 4 to complete another 12 hour inpatient visit with the schedule of activities identical to Day 1.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Oregon
-
Portland, Oregon, Stany Zjednoczone, 97239
- Oregon Health and Science University
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Diagnosis of type 1 diabetes mellitus for at least 1 year.
- Physically willing and able to perform 45 min of exercise (as determined by the investigator after reviewing the subjects activity level)
- Current use of an insulin pump.
- Lives with another person age 18 or older who will be present while subject exercises at home and that can attend the training on using the system with the subject.
- Lives within 20 miles of OHSU.
- A1C<10%
- Willingness to follow all study procedures, including attending all clinic visits.
- Willingness to sign informed consent and HIPAA documents.
Exclusion Criteria:
- Female of childbearing potential who is pregnant or intending to become pregnant or breast-feeding, or is not using adequate contraceptive methods. Acceptable contraception includes birth control pill / patch / vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence.
- Any cardiovascular disease, defined as a clinically significant EKG abnormality at the time of screening or any history of: stroke, heart failure, myocardial infarction, angina pectoris, or coronary arterial bypass graft or angioplasty. Diagnosis of 2nd or 3rd degree heart block or any non-physiological arrhythmia judged by the investigator to be exclusionary.
- Renal insufficiency (GFR < 60 ml/min, using the MDRD equation as report by the OHSU laboratory).
- Liver failure, cirrhosis, or any other liver disease that compromises liver function as determined by the investigator.
- Hematocrit of less than or equal to 34%.
- Hypertensive subjects with systolic blood pressure >= 160 mmHg or diastolic blood pressure >= 100 mmHg despite treatment or who have treatment-refractory hypertension (e.g. requiring four or more medications).
- History of severe hypoglycemia during the past 12 months prior to screening visit or hypoglycemia unawareness as judged by the investigator. Subjects will complete a hypoglycemia awareness questionnaire. Subjects will be excluded for four or more R responses.
- Adrenal insufficiency.
- Any active infection.
- Known or suspected abuse of alcohol, narcotics, or illicit drugs.
- Seizure disorder.
- Active foot ulceration.
- Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication.
- Major surgical operation within 30 days prior to screening.
- Use of an investigational drug within 30 days prior to screening.
- Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus).
- Bleeding disorder, treatment with warfarin, or platelet count below 50,000.
- Allergy to aspart insulin.
- Allergy to glucagon.
- Insulin resistance requiring more than 200 units per day.
- Need for uninterrupted treatment of acetaminophen.
- Current administration of oral or parenteral corticosteroids.
- Any life threatening disease, including malignant neoplasms and medical history of malignant neoplasms within the past 5 years prior to screening (except basal and squamous cell skin cancer).
- Beta blockers or non-dihydropyridine calcium channel blockers.
- Current use of any medication intended to lower glucose other than insulin (ex. use of liraglutide).
- Diagnosis of pheochromocytoma, insulinoma, or glucagonoma, personal or family history of multiple endocrine neoplasia (MEN) 2A, MEN 2B, neurofibromatosis or von Hippel-Lindau disease.
- History of severe hypersensitivity to milk protein.
- Current use of any medication with strong anticholinergic properties, such as antihistamines, sleep aids, and antidiarrheal medications.
- Current use of indomethacin.
- Conditions that may result in low levels of releasable glucose in the liver and an inadequate reversal of hypoglycemia by glucagon such as prolonged fasting, starvation or chronic hypoglycemia as determined by the investigator.
- A positive response to any of the questions from the Physical Activity Readiness Questionnaire.
- Any chest discomfort with physical activity, including pain or pressure, or other types of discomfort.
- Any clinically significant disease or disorder which in the opinion of the Investigator may jeopardize the subject's safety or compliance with the protocol.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
---|---|
Eksperymentalny: Predictive Low Glucose Suspend Arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient.
The predictive low glucose suspend system will run through the artificial pancreas controller in predictive low glucose suspend mode and utilize the patient's optimized basal rates, correction factor, and carb ratio, but it will have the additional safety net of the pump suspending insulin when it predicts a hypoglycemic event.
|
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component.
The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend.
Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to one Tandem t:slim insulin pumps filled with insulin.
|
Eksperymentalny: Dual Hormone Closed-loop Arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient using the closed-loop artificial pancreas controller in dual hormone mode to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery and an increase in glucagon delivery upon detection.
|
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component.
The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend.
Closed-loop Artificial Pancreas Controller includes insulin and glucagon delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to two Tandem t:slim insulin pumps, one filled with insulin and one with glucagon.
Inne nazwy:
|
Eksperymentalny: Single Hormone Closed-loop Arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient using the closed-loop artificial pancreas controller in single hormone mode to manage blood sugar that includes an exercise detection component that includes a reduction in insulin delivery upon detection.
|
The artificial pancreas controller contains an algorithm for managing blood glucose in people with type 1 diabetes which includes an exercise detection component.
The new algorithm will have 3 modes: a single hormone closed-loop insulin only mode, a dual-hormone closed-loop insulin and glucagon mode and an insulin only mode with predictive low glucose suspend.
Closed-loop Artificial Pancreas Controller includes insulin delivery algorithm implemented on a smart phone, utilizing sensor glucose values from a Dexcom G4 sensor and sending delivery commands to one Tandem t:slim insulin pumps filled with insulin.
|
Aktywny komparator: Sensor Augmented Pump Therapy arm
Subjects will undergo an 84 hour study with 24 hours inpatient and 60 hour outpatient with subject's insulin pump and glucose sensor, if he/she typically uses one.
Subjects will still wear a heart rate monitor uploading to a smart phone.
|
Subject will continue on their subcutaneous delivery of insulin on his/her own insulin pump using their own basal rates and carb ratios for meal boluses, managing their blood sugar as they normally would.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Percent of Time With Sensed Glucose < 3.9 mmol/L
Ramy czasowe: entire 84 hour study
|
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.9 mmol/L using Dexcom sensor downloads across all four arms.
|
entire 84 hour study
|
Percent of Time With Sensed Glucose < 3.9 mmol/L
Ramy czasowe: From 14:00-18:00 for each 12 hour inpatient visit
|
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.9 mmol/L using Dexcom sensor downloads across all four arms.
|
From 14:00-18:00 for each 12 hour inpatient visit
|
Percent of Time With Sensed Glucose Between 3.9-10 mmol/L
Ramy czasowe: entire 84 hour study
|
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values between 3.9-10 mmol/L using Dexcom sensor downloads across all four arms.
|
entire 84 hour study
|
Percent of Time With Sensed Glucose Between 3.9-10 mmol/L
Ramy czasowe: From 14:00-18:00 for each 12 hour inpatient visit
|
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values between 3.9-10 mmol/L using Dexcom sensor downloads across all four arms.
|
From 14:00-18:00 for each 12 hour inpatient visit
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Mean Sensed Glucose
Ramy czasowe: entire 84 hour study
|
Assess the mean sensor glucose using Dexcom sensor downloads across all four arms.
|
entire 84 hour study
|
Number of Carbohydrate Treatments
Ramy czasowe: entire 84 hour study
|
Assess the number of rescue carbohydrate treatments per day across all four arms.
|
entire 84 hour study
|
Percent of Time With Sensed Glucose < 3.0 mmol/L
Ramy czasowe: entire 84 hour study
|
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values less than 3.0 mmol/L using Dexcom sensor downloads across all four arms.
|
entire 84 hour study
|
Percent of Time With Sensed Glucose > 10 mmol/L
Ramy czasowe: entire 84 hour study
|
Assess the percent of time that the Dexcom G4 Share reported sensor glucose values greater than 10 mmol/L using Dexcom sensor downloads across all four arms
|
entire 84 hour study
|
Number of Events With Capillary Blood Glucose < 3.9 mmol/L
Ramy czasowe: entire 84 hour study
|
Assess number of events with capillary blood glucose < 3.9 mmol/L using downloads from a Contour Next blood glucose meter across all four arms. .
|
entire 84 hour study
|
Number of Events With Capillary Blood Glucose < 3.0 mmol/L
Ramy czasowe: entire 84 hour study
|
Assess number of events with capillary blood glucose < 3.0 mmol/L using downloads from a Contour Next blood glucose meter across all four arms.
|
entire 84 hour study
|
Mean Amount of Insulin Delivered
Ramy czasowe: 24 hours
|
Assess the average amount of insulin delivered per day in units/kg as documented through the artificial pancreas controller across all four arms.
|
24 hours
|
Mean Amount of Glucagon Delivered
Ramy czasowe: 24 hours
|
Assess the average amount of insulin delivered per day in units/kg as documented through the artificial pancreas controller in dual hormone arm.
|
24 hours
|
Współpracownicy i badacze
Publikacje i pomocne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
- Zaburzenia metabolizmu glukozy
- Choroby metaboliczne
- Choroby układu odpornościowego
- Choroby Autoimmunologiczne
- Choroby układu hormonalnego
- Cukrzyca
- Cukrzyca typu 1
- Fizjologiczne skutki leków
- Środki żołądkowo-jelitowe
- Hormony, substytuty hormonów i antagoniści hormonów
- Hormony
- Pankrelipaza
- Pankreatyna
Inne numery identyfikacyjne badania
- 15590 (Inny identyfikator: REB)
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Cukrzyca typu 1
-
Leiden University Medical CenterZakończonyGruczolak przysadki | Guz przysadki | Diabetes Insipidus Cranial Type | Dokrewny; NiedobórHolandia
-
National Center for Research Resources (NCRR)Northwestern UniversityZakończonyMoczówka prosta | Diabetes Insipidus, NeurohypophysealStany Zjednoczone
-
Ferring PharmaceuticalsZakończonyCentralna moczówka prostaJaponia
-
Universitair Ziekenhuis BrusselZakończonyNefrogenna moczówka prostaBelgia
-
National Center for Research Resources (NCRR)Northwestern UniversityZakończonyDiabetes Insipidus, nefrogenny
-
Emory UniversityZakończony
-
Oxford Brookes UniversityUniversity of OxfordZakończonyAktywność fizyczna | Zdrowie psychiczne Wellness 1 | Funkcja poznawcza 1, społeczna | Academic Attainment | Fitness TestingZjednoczone Królestwo
-
Elizabeth Austen LawsonJeszcze nie rekrutacjaCentralna moczówka prostaStany Zjednoczone
-
University of Colorado, DenverUniversity of AarhusZakończonyNefrogenna moczówka prostaStany Zjednoczone, Dania
-
Merck Sharp & Dohme LLCRekrutacyjnyNiedrobnokomórkowego raka płuca | Guzy lite | Zaprogramowana śmierć komórki-1 (PD1, PD-1) | Programowana śmierć komórki 1 Ligand 1 (PDL1, PD-L1) | Programowana śmierć komórki 1 Ligand 2 (PDL2, PD-L2)Japonia