Evaluation of Lower Extremity Tissue Perfusion With Polarized Laser Light
A Feasibility Study of Using Technology Based on Polarized Laser Light and Speed Camera for Non-invasive Tissue Perfusion Assessment of the Lower Extremities
Studieoversigt
Status
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
An objective assessment of blood supply and oxygen delivery to the damaged tissue in patients with diabetic ulcer is very problematic with various currently accepted auxiliary examinations. These tests include measuring blood pressure ratio between the ankle or toes arm (ABI \ TBI), Sonar Doppler examination of the lower limb arteries, and percutaneous tissue oxygen tension examination (TcPO2). Each of these tests, along with the obvious advantages esprit ability to assess a non-invasive blood as number of disadvantages.
As the blood supply to the tissue is the most important healing of the tissue regardless of the type of intervention chosen (conservative treatment includes systemic antibiotics or surgical debridement), there is clear necessity for a non-invasive test with high reliably assessing tissue perfusion in patients with diabetic ulcers.
Recently, a new a method for assessing multiple features in vital tissues using polarised laser light was introduced. The technique is based on tracking temporal changes of reflected secondary speckles produced in the skin when being illuminated by a laser beam. Change in skin's temporal vibration profile is generated by time varied oxygen concentration caused these temporal changes. This technology of nanometer motion sensing allows, according to studies already carried out, monitoring parameters such as blood pressure, pulse rate and heart rhythm, glucose concentration in the blood substances and alcohol, oxygen saturation and intraocular pressure.
In this study the investigators will examine, non-invasively, the tissue around the lower limb ulcers of 30 diabetic patients, beginning with the TcPO2 examination followed by the polarised laser light and complementary metal-oxide semiconductor (CMOS) camera examination, and analysing the data in order to determine the ability of the latter method for assessing the tissue oxygen pressure.
Undersøgelsestype
Tilmelding (Forventet)
Fase
- Ikke anvendelig
Kontakter og lokationer
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Patients suffering from chronic diabetic ulcers
Exclusion Criteria:
- Patients after amputation of some part in the lower limb
- Patients with acute infection on bony involvement
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Diagnostisk
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: Patients with diabetic feet ulcers
Each patient will be examined twice, first with TcPO2 (TCM400, Radiometer Medical ApS, Denmark) and then with a green laser (harmonic of continuous neodymium-doped yttrium aluminium garnet laser 532-nm wavelength and fast camera (PixelLink PLE531) system.
|
Andre navne:
Andre navne:
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Correlation between TcPO2 results and reflected secondary speckle patterns
Tidsramme: through study completion, an average of 1 year
|
recording and comparing between the examinations of each diabetic ulcer
|
through study completion, an average of 1 year
|
Samarbejdspartnere og efterforskere
Sponsor
Samarbejdspartnere
Efterforskere
- Studieleder: Meir Nyska, Prof., Head of the orthopaedic department
Publikationer og nyttige links
Generelle publikationer
- Rayman G, Williams SA, Spencer PD, Smaje LH, Wise PH, Tooke JE. Impaired microvascular hyperaemic response to minor skin trauma in type I diabetes. Br Med J (Clin Res Ed). 1986 May 17;292(6531):1295-8. doi: 10.1136/bmj.292.6531.1295.
- LoGerfo FW, Coffman JD. Current concepts. Vascular and microvascular disease of the foot in diabetes. Implications for foot care. N Engl J Med. 1984 Dec 20;311(25):1615-9. doi: 10.1056/NEJM198412203112506. No abstract available.
- Consensus development conference on diabetic foot wound care. 7-8 April 1999, Boston, MA. American Diabetes Association. Adv Wound Care. 1999 Sep;12(7):353-61. No abstract available.
- Schaper NC, Andros G, Apelqvist J, Bakker K, Lammer J, Lepantalo M, Mills JL, Reekers J, Shearman CP, Zierler RE, Hinchliffe RJ. Diagnosis and treatment of peripheral arterial disease in diabetic patients with a foot ulcer. A progress report of the International Working Group on the Diabetic Foot. Diabetes Metab Res Rev. 2012 Feb;28 Suppl 1:218-24. doi: 10.1002/dmrr.2255.
- Alexandrescu VA, Hubermont G, Philips Y, Guillaumie B, Ngongang C, Vandenbossche P, Azdad K, Ledent G, Horion J. Selective primary angioplasty following an angiosome model of reperfusion in the treatment of Wagner 1-4 diabetic foot lesions: practice in a multidisciplinary diabetic limb service. J Endovasc Ther. 2008 Oct;15(5):580-93. doi: 10.1583/08-2460.1.
- Lukkari-Rautiarinen E, Lepantalo M, Pietila J. Reproducibility of skin blood flow, perfusion pressure and oxygen tension measurements in advanced lower limb ischaemia. Eur J Vasc Surg. 1989 Aug;3(4):345-50. doi: 10.1016/s0950-821x(89)80072-6.
- Beiderman Y, Amsel AD, Tzadka Y, Fixler D, Mico V, Garcia J, Teicher M, Zalevsky Z. A microscope configuration for nanometer 3-D movement monitoring accuracy. Micron. 2011 Jun;42(4):366-75. doi: 10.1016/j.micron.2010.05.020. Epub 2010 Sep 19.
- Zalevsky Z, Beiderman Y, Margalit I, Gingold S, Teicher M, Mico V, Garcia J. Simultaneous remote extraction of multiple speech sources and heart beats from secondary speckles pattern. Opt Express. 2009 Nov 23;17(24):21566-80. doi: 10.1364/OE.17.021566.
- Beiderman Y, Horovitz I, Burshtein N, Teicher M, Garcia J, Mico V, Zalevsky Z. Remote estimation of blood pulse pressure via temporal tracking of reflected secondary speckles pattern. J Biomed Opt. 2010 Nov-Dec;15(6):061707. doi: 10.1117/1.3505008.
- Beiderman Y, Blumenberg R, Rabani N, Teicher M, Garcia J, Mico V, Zalevsky Z. Demonstration of remote optical measurement configuration that correlates to glucose concentration in blood. Biomed Opt Express. 2011 Mar 14;2(4):858-70. doi: 10.1364/BOE.2.000858.
- Ozana N, Arbel N, Beiderman Y, Mico V, Sanz M, Garcia J, Anand A, Javidi B, Epstein Y, Zalevsky Z. Improved noncontact optical sensor for detection of glucose concentration and indication of dehydration level. Biomed Opt Express. 2014 May 22;5(6):1926-40. doi: 10.1364/BOE.5.001926. eCollection 2014 Jun 1.
- Margalit I, Beiderman Y, Skaat A, Rosenfeld E, Belkin M, Tornow RP, Mico V, Garcia J, Zalevsky Z. New method for remote and repeatable monitoring of intraocular pressure variations. J Biomed Opt. 2014 Feb;19(2):027002. doi: 10.1117/1.JBO.19.2.027002.
- Golberg M, Fixler D, Shainberg A, Zlochiver S, Mico V, Garcia J, Beiderman Y, Zalevsky Z. Speckle-based configuration for simultaneous in vitro inspection of mechanical contractions of cardiac myocyte cells. J Biomed Opt. 2013 Oct;18(10):101310. doi: 10.1117/1.JBO.18.10.101310.
Datoer for undersøgelser
Studer store datoer
Studiestart
Primær færdiggørelse (Forventet)
Studieafslutning (Forventet)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
- MMC1602-16CTIL
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .