Can Surface Roughness Predict Progression of Tooth Wear?
Can Surface Roughness Predict Progression of Tooth Wear in Participants With Dietary Origins of Acid?
Studieoversigt
Detaljeret beskrivelse
60 unpolished and 60 polished enamel samples were prepared from extracted human molars collected under ethical approval.
30 healthy volunteers were recruited and lower dental impressions were recorded using standard stock trays. Custom made lower orthoodontic type appliances were made by the laboratory to accommodate a total of four enamel (2 left and right hand side) samples positioned buccally in the premolar/molar region.
The volunteers were randomly allocated into one of 3 groups: 5 mins erosion repeated x3, 10 mins erosion repeated x3 or 15 mins erosion repeated x3 and a coin was flipped to determine which side the samples were to be removed for ex vivo immersion with tails for left and heads for right. . At the beginning of the study visit the splints were inserted and worn for 30 minutes. Following which the enamel samples (1 polished and 1 unpolished) were removed from one side to begin the erosion regime. For in vivo erosion each participant was asked to rinse with orange juice for their either time 5, 10 or 15 minutes. This was standardised by setting up cups with 10 mL of the orange juice and a timer set at 1 minute. The participant was asked to insert the liquid into their mouths start the time and when the alarm sounded expectorate and repeat until they completed his/her time allocation of either 5, 10 or 15 minutes. Simultaneously the ex vivo samples were immersed in 20 mL of orange juice and agitated at 62 rpm for the allocated time using an orbital shaker (Stuart Scientific, Mini Orbital Shaker S05, Bibby). This completed one cycle after which the removed samples were reinserted into the splint which was worn for a further hour after which the rinsing/immersion regime was repeated. The process was repeated a further instance to complete 3 cycles of erosion. After the 3rd and final erosion cycle the participants were given a desensitising toothpaste Sensodyne Repair & Protect (GSK, Weybridge, UK).
The unpolished enamel samples were analysed before and after the experiment to measure changes in surface texture. Whereas, the polished samples were analysed for surface texture, hardness change and tissue loss.
Undersøgelsestype
Tilmelding (Faktiske)
Fase
- Ikke anvendelig
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- mild erosive tooth wear maximum score of 2 in each sextant and cumulative score no more than 8, aged 18 years and over, willing to participate, not enrolled in any other research, more than 20 anterior and posterior teeth, no active carious lesions and a maximum BPE score of 2 in one sextant (no periodontal disease).
Exclusion Criteria:
- pregnancy or breast feeding, medical history likely to impact on attendance or mobility, insulin dependent diabetes, saliva diagnoses (xerostomia), lower orthodontic appliances, dentine hypersensitivity, defective restoration of the occlusal or incisal surfaces of upper anterior teeth and first molars and any condition that precluded consumption of 300 ml of orange juice a day for 5 consecutive days.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Andet
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: 15 minutes' erosion
Orange juice is administered ex vivo and in vivo for 5 minutes and repeated a total of 3 times
|
3 immersion times in orange juice were investigated
|
|
Eksperimentel: 30 minutes' erosion
Orange juice is administered ex vivo and in vivo for 10 minutes and repeated a total of 3 times
|
3 immersion times in orange juice were investigated
|
|
Eksperimentel: 45 minutes' erosion
Orange juice is administered ex vivo and in vivo for 15 minutes and repeated a total of 3 times
|
3 immersion times in orange juice were investigated
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Microhardness (KHN)
Tidsramme: 12 weeks
|
To measure microhardness of enamel samples using a microhardness tester before and after the intervention.
The units will be KHN
|
12 weeks
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Surface roughness
Tidsramme: 12 weeks
|
To measure surface roughness of enamel samples using anon contact profilometer before and after the intervention.
The units will be microns.
|
12 weeks
|
|
Step height loss
Tidsramme: 12 weeks
|
To measure step height loss of enamel samples following the intervention using a non contact profilometer.
The units will be microns.
|
12 weeks
|
Samarbejdspartnere og efterforskere
Sponsor
Samarbejdspartnere
Publikationer og nyttige links
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Faktiske)
Studieafslutning (Faktiske)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- 15/LO/0417
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Tandslid
-
University of LiegeDMG Paris DescartesUkendtZirconia Monolithic Dental Restorations: In-mouth Behaviour, LTD og WearBelgien
-
Hereditary Neuropathy FoundationRekrutteringCharcot-Marie-Tooth sygdom | Charcot-Marie-Tooth sygdom, type IA | Charcot-Marie-Tooth sygdom type 2A | Charcot-Marie-Tooth | Charcot-Marie-Tooth sygdom, type IB | Charcot-Marie-Tooth sygdom type 2 | Charcot-Marie-Tooth sygdom, type 2C | Charcot-Marie-Tooth sygdom type 2A2B | Charcot-Marie-Tooth sygdom... og andre forholdForenede Stater
-
n-Lorem FoundationThe University of Texas Health Science Center, HoustonTilmelding efter invitationCharcot-Marie-Tooth sygdom type 2DForenede Stater
-
Elpida Therapeutics SPCIkke rekrutterer endnuCharcot-Marie-Tooth Sygdom Type 4J
-
Tanta UniversityRekrutteringMTA Vital Tooth PulpotomiEgypten
-
University of Health Sciences LahoreIkke rekrutterer endnuIrreversibel Pulpitis | Pulpotomi | MTA Vital Tooth PulpotomiPakistan
-
University College, LondonUniversity of IowaUkendtCharcot-Marie-Tooth sygdom, type IA | Charcot-Marie-Tooth sygdom type 2A | Charcot-Marie-Tooth sygdom, type IB | Charcot-Marie-Tooth sygdom, type XDet Forenede Kongerige
-
Ain Shams UniversityRekrutteringDental Caries Tooth Demineralisering | Post-ortodontiske æstetiske defekterEgypten
-
Tri-Service General HospitalAfsluttetEarly Childhood Caries (ECC) | Dental Caries Tooth DemineraliseringTaiwan
-
University Hospital, Clermont-FerrandAfsluttetCharcot-Marie-Tooth Type 1A neuropatiFrankrig
Kliniske forsøg med Orange juice
-
Universiti Teknologi MaraUniversiti Putra Malaysia; Ministry of Health, Malaysia; Institute for Health... og andre samarbejdspartnereRekrutteringSundhedsholdning | Sundhedsadfærd | Viden, holdninger, praksis | Sundhedsviden, holdninger, praksis | Sundhedsrelateret adfærd | Opførsel, sundhed | Holdning til sundhed | Beredskab | UdbrudMalaysia