- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT03858257
High Flow Nasal Oxygen During Sedation
9. november 2020 opdateret af: Aaron Conway, University Health Network, Toronto
High Flow Nasal Oxygen During Conscious Sedation in the Cardiac Catheterisation Laboratory: A Randomized Controlled Trial
The primary objective of this study is to test the hypothesis that using high flow nasal oxygen improves ventilation during cardiac implantable electronic device procedures performed with conscious sedation.
A randomized controlled trial design will be used with participants randomized in a 1:1 ratio to oxygen supplementation through a standard facemask or high flow nasal oxygen.
Studieoversigt
Status
Afsluttet
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
High flow nasal oxygen (HFNO) is increasingly regarded as a promising technology for oxygen delivery in critical care and anesthetic management.
Although promising, further high-quality studies examining the effects of using HFNO during procedural sedation are required to inform decision-making regarding implementation of this new technology into practice.
The 2018 guidelines from the American Society of Anesthesiology stated that there is insufficient evidence regarding which methods of supplemental oxygen administration (e.g., nasal cannula, face mask, or specialized devices such as HFNO) are more effective.
This trial will address this limitation in the evidence base specifically in regard to the efficacy of using HFNO during conscious sedation in the cardiac catheterisation laboratory.
Undersøgelsestype
Interventionel
Tilmelding (Faktiske)
129
Fase
- Ikke anvendelig
Kontakter og lokationer
Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.
Studiesteder
-
-
Ontario
-
Toronto, Ontario, Canada
- Toronto General Hospital
-
-
Deltagelseskriterier
Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.
Berettigelseskriterier
Aldre berettiget til at studere
16 år og ældre (Barn, Voksen, Ældre voksen)
Tager imod sunde frivillige
Ingen
Køn, der er berettiget til at studere
Alle
Beskrivelse
Inclusion criteria:
1. Adults undergoing an elective cardiac implantable electronic device procedure in the Peter Munk Cardiac Centre Cardiac Cath Labs with conscious sedation administered by an Anesthetic Assistant (de novo and replacement/revision procedures).
Exclusion criteria:
- Under 16 years of age.
- Underlying condition requiring chronic oxygen supplementation.
- Diagnosed respiratory condition with confirmed current hypercapnia.
- Pre-existing untreated pneumothorax.
- Transesophageal echocardiography planned for the procedure.
- Active nasal bleeding.
- Complete nasal obstruction.
- Recent upper airway surgery or base of skull fracture.
- Previous participation in the study.
Studieplan
Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Sundhedstjenesteforskning
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: High flow nasal oxygen
The gas temperature will commence at the 'High' setting (ranges 30-32º Celsius) and titrated downwards if the patient complains of irritation.
The gas flow rate will commence at 30 liters per minute prior to sedation administration and be titrated up to 70 liters per minute as tolerated by the patient after sedation has been administered.
The fraction of oxygen in the gas will be commenced at 50% (same as that delivered from 6 liters per minute via facemask) and can be titrated upward according to patient requirements (i.e.
increased if there is evidence of hypoventilation, airway obstruction or inadequate oxygenation, decreased during use of diathermy).
Anesthesia Assistants at the site will be provided with training in the use of this mode of oxygen delivery prior to study commencement.
|
The Optiflow device (Fisher and Paykel Healthcare, Auckland, New Zealand) will be used.
|
|
Andet: Standard oxygenation
Supplemental oxygen through a facemask with the flow rate chosen by the clinician responsible for sedation as per their standard practice.
The oxygen flow rate is typically commenced at 6 liters per minute and can be titrated up to 15 liters per minute.
|
Supplemental oxygen through a facemask.
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Peak transcutaneous carbon dioxide (TcCO2) concentration.
Tidsramme: From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
Continuous measurements will be recorded using the Sentec Digital Monitoring with VSign 2 sensor.
|
From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Mean transcutaneous carbon dioxide concentration
Tidsramme: From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
Continuous measurements will be recorded using the Sentec Digital Monitoring with VSign 2 sensor.
|
From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
|
Area under SpO2 90% oxygen desaturation curve
Tidsramme: From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
Percentage of hemoglobin saturated with oxygen (SpO2) will be measured continuously throughout procedures as part of routine clinical practice through the anaesthetic machine.
This is a composite measure comprising the incidence, depth, and duration of oxygen desaturation events.
Area under SpO2 90% oxygen desaturation curve is calculated as the difference between the threshold (90%) and actual oxygen saturation (SpO2) summed every second during which oxygen saturation was below threshold.
|
From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
|
Adverse sedation events
Tidsramme: From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
The Anaesthesia Assistant will be asked to complete the Tracking and reporting outcomes of procedural sedation (TROOPS) tool at the end of procedures.
Completion of the tool requires identification and description of the adverse event, the intervention, the outcome and the overall severity of the adverse event.
|
From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
|
Patient satisfaction with sedation: Iowa Satisfaction with Anesthesia Scale
Tidsramme: After the participant has reached phase 2 post-anesthetic recovery. Estimated to be 30 minutes after procedure has finished.
|
Iowa Satisfaction with Anesthesia Scale.
Score ranges from -3 (worse satisfaction) to +3 (better satisfaction).
|
After the participant has reached phase 2 post-anesthetic recovery. Estimated to be 30 minutes after procedure has finished.
|
|
Costs associated with oxygen delivery
Tidsramme: From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
Anesthesia Assistants will document devices used for supplemental oxygen delivery and airway management in both groups as per their usual practice in the anesthesia monitoring system.
|
From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
|
Anesthesia Assistant rating of difficulty maintaining the patient's oxygenation status
Tidsramme: To be completed as soon as possible after the end of the procedure (within about 5 minutes).
|
The Anaesthesia Assistant will be asked to rate their perceived level of difficulty in maintaining oxygenation using a 6-level rating scale with ratings of "extremely difficult", "very difficult", "difficult", "easy", "very easy", "extremely easy".
|
To be completed as soon as possible after the end of the procedure (within about 5 minutes).
|
|
Anesthesia Assistant rating of difficulty using oxygen delivery device
Tidsramme: To be completed as soon as possible after the end of the procedure (within about 5 minutes).
|
The Anaesthesia Assistant will be asked to rate their perceived level of difficulty using the oxygen delivery device using a 6-level rating scale with ratings of "extremely difficult", "very difficult", "difficult", "easy", "very easy", "extremely easy".
|
To be completed as soon as possible after the end of the procedure (within about 5 minutes).
|
|
Patient comfort of oxygen delivery
Tidsramme: After the participant has reached phase 2 post-anesthetic recovery. Estimated to be 30 minutes after procedure has finished.
|
Participants will be asked to rate at the end of procedures their perceived overall comfort with the oxygen delivery device used during the procedure using a 6-level rating scale with ratings of 'maximal discomfort', 'very uncomfortable', 'uncomfortable', 'comfortable', 'very comfortable' and 'maximal comfort'.
|
After the participant has reached phase 2 post-anesthetic recovery. Estimated to be 30 minutes after procedure has finished.
|
|
Trajectory of transcutaneous carbon dioxide as a function of time
Tidsramme: From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
Continuous measurements will be recorded using the Sentec Digital Monitoring with VSign 2 sensor
|
From the time between first sedative medication administration to the end of the procedure. Estimated duration of procedures is 30 minutes to 120 minutes.
|
Samarbejdspartnere og efterforskere
Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.
Efterforskere
- Ledende efterforsker: Aaron Conway, RN, PhD, University Health Network, Toronto
Publikationer og nyttige links
Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.
Datoer for undersøgelser
Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.
Studer store datoer
Studiestart (Faktiske)
7. august 2019
Primær færdiggørelse (Faktiske)
12. marts 2020
Studieafslutning (Faktiske)
12. marts 2020
Datoer for studieregistrering
Først indsendt
25. februar 2019
Først indsendt, der opfyldte QC-kriterier
27. februar 2019
Først opslået (Faktiske)
28. februar 2019
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
12. november 2020
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
9. november 2020
Sidst verificeret
1. november 2020
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- 18-6343
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
JA
IPD-planbeskrivelse
Study data, participant-level data sets (without identifying information) and code for statistical analyses will be shared in a publicly accessible repository at the time of publication.
IPD-delingstidsramme
With publication of results.
IPD-delingsadgangskriterier
Available through a public repository
IPD-deling Understøttende informationstype
- STUDY_PROTOCOL
- SAP
- ICF
- ANALYTIC_CODE
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Ingen
Studerer et amerikansk FDA-reguleret enhedsprodukt
Ingen
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .