Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Digital VS Conventional Altered Cast Technique for Mandibular Bilateral Distal Extension RPDs

7. maj 2026 opdateret af: Kareem Mohammed Reda, Tanta University

Digital VS Conventional Altered Cast Technique for Mandibular Bilateral Distal Extension Removable Partial Denture

This study aims to compare outcomes of digitally created altered casts with conventional altered casts in mandibular bilateral distal-extension cases.

Studieoversigt

Detaljeret beskrivelse

Partially dentate adults represent an increasing proportion of the population, driven by increased life expectancy and a demographic shift from total edentulism toward partial edentulism. Fabrication of removable partial dentures for distal extension edentulous ridges presents significant clinical complexity because the teeth and residual ridge possess fundamentally different degrees of displaceability. Optimum denture support re-quires recording teeth in anatomical form and the mucosa in functional form .

The altered cast impression technique , introduced by Applegate, remains one of the most widely accepted methods for achieving optimal tissue support and accurate denture base positioning relative to tooth abutments . removable partial dentures fabricated using altered cast impression technique demonstrate improved patient comfort and preservation of oral health . However, despite these advantages, debate persists regarding the clinical significance of altered cast impression technique over single-impression techniques .

Recent advances in computer-aided design and computer-aided manufacturing have transformed the removable partial dentures framework, opening new pathways in the fabrication of RPD through additive and subtractive manufacturing . Digital intraoral scanning offers advantages, including reduced dimensional error, improved efficiency, and real-time feedback on impression accuracy and extension [13-16]. However, intraoral scanning techniques are inherently mucostatic and image-based, rendering the recording of functional impression impossible, a limitation acknowledged as necessary for optimal support in distal extension removable partial dentures . Lab scanning of conventionally prepared altered casts pre-pared by traditional methods fails to eliminate inherited errors from cast separation and reassembly.

Recent studies have introduced hybrid digital workflows that combine functional registration of the edentulous ridge with mucostatic scanning of the remaining oral structures in an effort to reproduce conventional clinical procedures while improving efficiency and precision . Most investigations on digital technology in RPD have concentrated on methods for fabricating metal frameworks and evaluating their performance.

This study aims to compare outcomes of digitally created altered casts with conventional altered casts in mandibular bilateral distal-extension cases.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

7

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Tanta, Egypten
        • Tanta University

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Voksen

Tager imod sunde frivillige

Ingen

Beskrivelse

Inclusion Criteria:

  • Patients presented with bilateral, well-formed mandibular distal extension residual ridges covered by keratinized mucosa, with a minimum thickness of 1.5-3 mm .
  • Each participant had a sound first or second premolar serving as the terminal abutment, with a crown-to-root ratio of ≥ 1:2.
  • Comprised fully or partially dentate maxillary arches, an Angle Class I molar relationship, and adequate interarch space (7-8 mm) to accommodate the prosthesis .

Exclusion Criteria:

  • The presence of systemic conditions affecting bone metabolism or healing
  • pathological conditions in the edentulous area (e.g., residual cysts, retained roots, or severe ridge re-sorption);
  • parafunctional habits such as bruxism, clenching, or tongue thrusting
  • pro-nounced anatomical undercuts in the lingual mandible or adjacent to abutment teeth that could impede denture fabrication or insertion.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Digital workflow and Digital altered cast group
Digital selective tissue placement was performed within the same Exocad design project using the free-form scan-data tool, paint and pull feature to apply the principles of selective tissue pressure technique . Using free form mesh editing tools, the buccal shelf area opposing teeth 37 and 47 was identified, and controlled tissue ward displacement of the mucosal surface was simulated while monitoring the magnitude of displacement on sectional views and with digital measurement tools. Figure 2B, F The modified mandibular dataset was saved as the digitally altered cast STL (DA), which served as the basis for the digital RPD design and subsequent denture base fabrication.
The RPD design features of fully digitally fabricated RPD illustrated in Figure 2A. Digital selective tissue placement was performed within the same Exocad design project using the free-form scan-data tool, paint and pull feature to apply the principles of selective tissue pressure technique . Using free form mesh editing tools, the buccal shelf area opposing teeth 37 and 47 was identified, and controlled tissue ward displacement of the mucosal surface was simulated while monitoring the magnitude of displacement on sectional views and with digital measurement tools.
Eksperimentel: Conventional workflow and conventional altered cast group
For the CA cast technique, one of the SLM frameworks (MF2) was adapted on the stone master cast and used as a functional impression tray (Acrostone Dental Manufacturing, Cairo, Egypt) over the distal extension areas. A selec-tive pressure impression was made according to the traditional altered cast protocol, with the distal saddle areas repoured in dental stone to obtain the CA cast. This CA was then digitized using a desktop scanner (Dove Technologies, Suzhou, China) to produce the CA cast STL. Wax rims were used to verify the jaw relationship, and the maxillary cast was mounted using a facebow transfer on a semi adjustable articulator (A7 Plus, Bio-Art Equi-pamentos Odontológicos Ltda., São Carlos, SP, Brazil), while the mandibular cast was mounted in maximum intercuspation.
For the CA cast technique, one of the SLM frameworks (MF2) was adapted on the stone master cast and used as a functional impression tray (Acrostone Dental Manufacturing, Cairo, Egypt) over the distal extension areas. A selec-tive pressure impression was made according to the traditional altered cast protocol, with the distal saddle areas repoured in dental stone to obtain the CA cast. This CA was then digitized using a desktop scanner (Dove Technologies, Suzhou, China) to produce the CA cast STL. Wax rims were used to verify the jaw relationship, and the maxillary cast was mounted using a facebow transfer on a semi adjustable articulator (A7 Plus, Bio-Art Equi-pamentos Odontológicos Ltda., São Carlos, SP, Brazil), while the mandibular cast was mounted in maximum intercuspation. Semi anatomic acrylic teeth (Acrostone Dental Manufacturing, Cairo, Egypt.) were arranged, and wax try ins were evaluated intraorally in a conventional manner prior to processing.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
Assessment of the condition of ridge mucosal covering of the Removable Partial Denture constructed out of digitally altered model.
Tidsramme: at 15 days, 3 months and 6 months .
at 15 days, 3 months and 6 months .

Sekundære resultatmål

Resultatmål
Tidsramme
Denture base fit by Pressure Indicating Paste
Tidsramme: one month
one month

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

30. maj 2021

Primær færdiggørelse (Faktiske)

30. november 2024

Studieafslutning (Faktiske)

30. november 2024

Datoer for studieregistrering

Først indsendt

1. maj 2026

Først indsendt, der opfyldte QC-kriterier

7. maj 2026

Først opslået (Faktiske)

13. maj 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

13. maj 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

7. maj 2026

Sidst verificeret

1. maj 2021

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • R-RP-5-21-10

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner