Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Digital VS Conventional Altered Cast Technique for Mandibular Bilateral Distal Extension RPDs

7. Mai 2026 aktualisiert von: Kareem Mohammed Reda, Tanta University

Digital VS Conventional Altered Cast Technique for Mandibular Bilateral Distal Extension Removable Partial Denture

This study aims to compare outcomes of digitally created altered casts with conventional altered casts in mandibular bilateral distal-extension cases.

Studienübersicht

Detaillierte Beschreibung

Partially dentate adults represent an increasing proportion of the population, driven by increased life expectancy and a demographic shift from total edentulism toward partial edentulism. Fabrication of removable partial dentures for distal extension edentulous ridges presents significant clinical complexity because the teeth and residual ridge possess fundamentally different degrees of displaceability. Optimum denture support re-quires recording teeth in anatomical form and the mucosa in functional form .

The altered cast impression technique , introduced by Applegate, remains one of the most widely accepted methods for achieving optimal tissue support and accurate denture base positioning relative to tooth abutments . removable partial dentures fabricated using altered cast impression technique demonstrate improved patient comfort and preservation of oral health . However, despite these advantages, debate persists regarding the clinical significance of altered cast impression technique over single-impression techniques .

Recent advances in computer-aided design and computer-aided manufacturing have transformed the removable partial dentures framework, opening new pathways in the fabrication of RPD through additive and subtractive manufacturing . Digital intraoral scanning offers advantages, including reduced dimensional error, improved efficiency, and real-time feedback on impression accuracy and extension [13-16]. However, intraoral scanning techniques are inherently mucostatic and image-based, rendering the recording of functional impression impossible, a limitation acknowledged as necessary for optimal support in distal extension removable partial dentures . Lab scanning of conventionally prepared altered casts pre-pared by traditional methods fails to eliminate inherited errors from cast separation and reassembly.

Recent studies have introduced hybrid digital workflows that combine functional registration of the edentulous ridge with mucostatic scanning of the remaining oral structures in an effort to reproduce conventional clinical procedures while improving efficiency and precision . Most investigations on digital technology in RPD have concentrated on methods for fabricating metal frameworks and evaluating their performance.

This study aims to compare outcomes of digitally created altered casts with conventional altered casts in mandibular bilateral distal-extension cases.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

7

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Tanta, Ägypten
        • Tanta University

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • Patients presented with bilateral, well-formed mandibular distal extension residual ridges covered by keratinized mucosa, with a minimum thickness of 1.5-3 mm .
  • Each participant had a sound first or second premolar serving as the terminal abutment, with a crown-to-root ratio of ≥ 1:2.
  • Comprised fully or partially dentate maxillary arches, an Angle Class I molar relationship, and adequate interarch space (7-8 mm) to accommodate the prosthesis .

Exclusion Criteria:

  • The presence of systemic conditions affecting bone metabolism or healing
  • pathological conditions in the edentulous area (e.g., residual cysts, retained roots, or severe ridge re-sorption);
  • parafunctional habits such as bruxism, clenching, or tongue thrusting
  • pro-nounced anatomical undercuts in the lingual mandible or adjacent to abutment teeth that could impede denture fabrication or insertion.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Digital workflow and Digital altered cast group
Digital selective tissue placement was performed within the same Exocad design project using the free-form scan-data tool, paint and pull feature to apply the principles of selective tissue pressure technique . Using free form mesh editing tools, the buccal shelf area opposing teeth 37 and 47 was identified, and controlled tissue ward displacement of the mucosal surface was simulated while monitoring the magnitude of displacement on sectional views and with digital measurement tools. Figure 2B, F The modified mandibular dataset was saved as the digitally altered cast STL (DA), which served as the basis for the digital RPD design and subsequent denture base fabrication.
The RPD design features of fully digitally fabricated RPD illustrated in Figure 2A. Digital selective tissue placement was performed within the same Exocad design project using the free-form scan-data tool, paint and pull feature to apply the principles of selective tissue pressure technique . Using free form mesh editing tools, the buccal shelf area opposing teeth 37 and 47 was identified, and controlled tissue ward displacement of the mucosal surface was simulated while monitoring the magnitude of displacement on sectional views and with digital measurement tools.
Experimental: Conventional workflow and conventional altered cast group
For the CA cast technique, one of the SLM frameworks (MF2) was adapted on the stone master cast and used as a functional impression tray (Acrostone Dental Manufacturing, Cairo, Egypt) over the distal extension areas. A selec-tive pressure impression was made according to the traditional altered cast protocol, with the distal saddle areas repoured in dental stone to obtain the CA cast. This CA was then digitized using a desktop scanner (Dove Technologies, Suzhou, China) to produce the CA cast STL. Wax rims were used to verify the jaw relationship, and the maxillary cast was mounted using a facebow transfer on a semi adjustable articulator (A7 Plus, Bio-Art Equi-pamentos Odontológicos Ltda., São Carlos, SP, Brazil), while the mandibular cast was mounted in maximum intercuspation.
For the CA cast technique, one of the SLM frameworks (MF2) was adapted on the stone master cast and used as a functional impression tray (Acrostone Dental Manufacturing, Cairo, Egypt) over the distal extension areas. A selec-tive pressure impression was made according to the traditional altered cast protocol, with the distal saddle areas repoured in dental stone to obtain the CA cast. This CA was then digitized using a desktop scanner (Dove Technologies, Suzhou, China) to produce the CA cast STL. Wax rims were used to verify the jaw relationship, and the maxillary cast was mounted using a facebow transfer on a semi adjustable articulator (A7 Plus, Bio-Art Equi-pamentos Odontológicos Ltda., São Carlos, SP, Brazil), while the mandibular cast was mounted in maximum intercuspation. Semi anatomic acrylic teeth (Acrostone Dental Manufacturing, Cairo, Egypt.) were arranged, and wax try ins were evaluated intraorally in a conventional manner prior to processing.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Zeitfenster
Assessment of the condition of ridge mucosal covering of the Removable Partial Denture constructed out of digitally altered model.
Zeitfenster: at 15 days, 3 months and 6 months .
at 15 days, 3 months and 6 months .

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Zeitfenster
Denture base fit by Pressure Indicating Paste
Zeitfenster: one month
one month

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

30. Mai 2021

Primärer Abschluss (Tatsächlich)

30. November 2024

Studienabschluss (Tatsächlich)

30. November 2024

Studienanmeldedaten

Zuerst eingereicht

1. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

7. Mai 2026

Zuerst gepostet (Tatsächlich)

13. Mai 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

13. Mai 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

7. Mai 2026

Zuletzt verifiziert

1. Mai 2021

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • R-RP-5-21-10

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren